Solar Lattice

Product

CPS SCH350KTL-DO/US-800

ID
prod:chint-sch-350ktl
IRI
https://solarlattice.org/kb/prod/chint-sch-350ktl
Status
active
Also known as
SCH 350 KTL, SCH 350 KTL DO US 800, SCH350KTL-DO/US-800
Category
Inverters
Make
chint
Product level
family

The CPS SCH350KTL-DO/US-800 is a CHINT Power Systems three-phase string inverter for 1500 V PV arrays. It connects to an 800 Vac, 60 Hz grid. It delivers up to 350 kW (350 kVA) and up to 253 A of AC output current. It has 15 MPP trackers, each with two non-fused DC inputs, and each tracker clips at 40 A. The MPPT voltage window is 880 to 1300 Vdc. The inverter operates on DC input from 500 to 1450 Vdc and starts at 550 Vdc. Peak efficiency is 99.00% and CEC efficiency is 98.50%. Power factor is above 0.99 and can be adjusted to ±0.8. It has Type II surge protection on both the DC and AC sides, and load-rated DC switches. Firmware upgrades are done by contacting CPS Customer Service. Fault codes include CommErr (communication error), ExtFanErr (cooling fan failure), CfLowErr (flying capacitor voltage too low) and Fault0110 (bus imbalance). For CfLowErr, remove the branch with the lowest input voltage. For Fault0110, raise the DCI limit first, and replace the inverter if the fault does not clear.

<!-- review notes

Claims

rated_power

c1 drafted · lead nominal 350 KiloW

Conditions: Maximum AC output power (selectable) at PF >0.99; apparent power 350 kVA

max_input_voltage

c2 drafted · lead nominal 1500 V

Conditions: Maximum DC input voltage

mppt_voltage_range

c3 drafted · lead 880–1300 V

Conditions: MPPT voltage range at PF >0.99; operating DC input range is 500-1450 Vdc

max_input_current

c4 verified · fact nominal 40 A

Conditions: Per MPPT, clipping point; 15 MPP trackers

verified by: review-workflowverified on: 2026-10-24

rated_output_current

c5 drafted · lead nominal 253 A

Conditions: Maximum AC output current at 800 Vac

nominal_voltage

c6 drafted · lead nominal 800 V

Conditions: Rated AC output voltage, 3-phase / PE grid connection

c7 drafted · lead 680–880 V

Conditions: AC output voltage operating range

frequency

c8 drafted · lead nominal 60 HZ

Conditions: Rated output frequency

c9 verified · fact 57–63 HZ

Conditions: Output frequency range

verified by: review-workflowverified on: 2026-10-24

efficiency

c10 drafted · lead nominal 99 PERCENT

Conditions: Maximum (peak) efficiency

review note: possible conflict with c11 (same source; check the conditions)

c11 drafted · lead nominal 98.5 PERCENT

Conditions: CEC weighted efficiency

review note: possible conflict with c10 (same source; check the conditions)

implements

c12 drafted · lead Maximum power point tracking

15 MPP trackers, 2 non-fused DC inputs per MPPT

c13 drafted · lead Surge protection

Type II surge protection on both DC and AC sides

c14 drafted · lead Constant power factor mode

Power factor >0.99, adjustable to ±0.8

certified_to

c15 drafted · lead UL 1741 SA proposed

c16 drafted · lead UL 1741 SB proposed

c17 drafted · lead IEEE 1547-2018 proposed

c18 drafted · lead FCC Part 15 proposed

c19 drafted · lead UL 1998 proposed

uses_protocol

c20 drafted · lead IEEE 2030.5

Listed among certifications and standards

Referenced by

Data