Schneider Electric CL125 033

Code
033
Shown as
Clamp capacitance pre-charge ground fault is detected
Page
126
ID
fc:schneider-electric-conext-cl125-33
IRI
https://solarlattice.org/kb/fc/schneider-electric-conext-cl125-33
Status
active
Also known as
033, 33, Schneider Electric 033, Clamp capacitance pre-charge ground fault is detected
Category
Inverters
Class not stated
Production not stated
Clears by itself drafted · lead

Decoded

Reports ground fault alarm or trip.

What can be behind Ground fault alarm or trip

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E018, ABB / FIMER PVS-60-TL E018, ABB / FIMER TRIO-20.0-27.6-TL E018, ABB / FIMER UNO-DM-3.3-5.0-PLUS E018, ABB / FIMER UNO-DM-6.0-PLUS E018
CPS
CPS SCA50-100K-T PFault0040, CPS SCA50-100K-T Protect0200
Enphase
Enphase M215-M250 GFI Tripped
Fronius
Fronius Galvo 475, Fronius Primo 475, Fronius Symo 475
Huawei
Huawei SUN2000-100KTL-USH0 2031
SMA
SMA SB-US-40 3501, SMA SB-US-40 3601, SMA SB-US-40 3701, SMA SB-US-41 3501, SMA SB-US-41 3601, SMA SB-US-41 3701, SMA SBSE-US-50 3501, SMA SBSE-US-50 3601, SMA SBSE-US-50 3701, SMA PEAK3-US 3501, SMA PEAK3-US 3601, SMA PEAK3-US 3701, SMA CORE1-US 3501, SMA CORE1-US 3701, SMA STP-TL-US 3501, SMA STP-TL-US 3601, SMA STP-TL-US 3701, SMA STP-X-US 3501, SMA STP-X-US 3601, SMA STP-X-US 3701, SMA SC-CP-XT 3501, SMA SC-CP-XT 3502, SMA SC-CP-XT 3507, SMA SC-CP-XT 3512, SMA SC-CP-XT 3515, SMA SC-CP-XT 3601, SMA SC-CP-XT 6487
Solis
Solis S6-EH2P PV ISO-PRO01, Solis S6-EH2P PV ISO-PRO02, Solis S6-EH3P30-60K PV ISO-PRO01, Solis S6-EH3P30-60K PV ISO-PRO02, Solis S6-EH3P75-150K PV ISO-PRO01, Solis S6-EH3P75-150K PV ISO-PRO02
Sungrow
Sungrow SG200HX 1600-1615, Sungrow SG200HX 1632-1655, Sungrow SG250HX 1600-1615, Sungrow SG250HX 1632-1655, Sungrow SG350HX 1600-1615, Sungrow SG350HX 1632-1655
Yaskawa Solectria
Yaskawa Solectria SGI-XTM DC GND Fault, Yaskawa Solectria SGI-XTM RCM Fault, Yaskawa Solectria XGI-1500-1MW CRIT-7, Yaskawa Solectria XGI-1500 CRIT-7, Yaskawa Solectria XGI-1500-DCG CRIT-7

Claims

defined_in

c1 drafted · lead Conext CL125 Owners Guide 975-0793 RevA

c2 drafted · lead Conext CL125 Modbus App Note

reports

c3 drafted · lead Ground fault alarm or trip

Detected during clamp capacitor pre-charge.

review note: support check: partial - Pre-charge ground fault is stated, but 'alarm or trip' is not.

has_recovery

c4 drafted · lead Auto-reset (clears by itself)

Contact technical support if the event persists.

review note: support check: partial - Auto recovery stated, but contact-support note is absent.

applies_to

c5 drafted · lead Schneider Electric Conext CL125