Fault codes › Huawei › Huawei SUN2000-100KTL-USH0
Huawei SUN2000-100KTL-USH0 2031
- Code
2031
- Shown as
- Phase Wire Short-Circuited to PE
- Vendor severity
- Major
- Page
- 119
- ID
fc:huawei-sun2000-100ktl-ush0-2031
- IRI
https://solarlattice.org/kb/fc/huawei-sun2000-100ktl-ush0-2031
- Status
- active
- Also known as
- 2031, Huawei 2031, Phase Wire Short-Circuited to PE
- Category
- Inverters
Class
fault drafted · lead
Production
stops drafted · lead
Clears
not stated
Decoded
Reports ground fault alarm or trip; look at AC cable; confirm with insulation resistance testing, fault localization.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E018, ABB / FIMER PVS-60-TL E018, ABB / FIMER TRIO-20.0-27.6-TL E018, ABB / FIMER UNO-DM-3.3-5.0-PLUS E018, ABB / FIMER UNO-DM-6.0-PLUS E018
- CPS
- CPS SCA50-100K-T PFault0040, CPS SCA50-100K-T Protect0200
- Enphase
- Enphase M215-M250 GFI Tripped
- Fronius
- Fronius Galvo 475, Fronius Primo 475, Fronius Symo 475
- SMA
- SMA SB-US-40 3501, SMA SB-US-40 3601, SMA SB-US-40 3701, SMA SB-US-41 3501, SMA SB-US-41 3601, SMA SB-US-41 3701, SMA SBSE-US-50 3501, SMA SBSE-US-50 3601, SMA SBSE-US-50 3701, SMA PEAK3-US 3501, SMA PEAK3-US 3601, SMA PEAK3-US 3701, SMA CORE1-US 3501, SMA CORE1-US 3701, SMA STP-TL-US 3501, SMA STP-TL-US 3601, SMA STP-TL-US 3701, SMA STP-X-US 3501, SMA STP-X-US 3601, SMA STP-X-US 3701, SMA SC-CP-XT 3501, SMA SC-CP-XT 3502, SMA SC-CP-XT 3507, SMA SC-CP-XT 3512, SMA SC-CP-XT 3515, SMA SC-CP-XT 3601, SMA SC-CP-XT 6487
- Schneider Electric
- Schneider Electric CL125 033
- Solis
- Solis S6-EH2P PV ISO-PRO01, Solis S6-EH2P PV ISO-PRO02, Solis S6-EH3P30-60K PV ISO-PRO01, Solis S6-EH3P30-60K PV ISO-PRO02, Solis S6-EH3P75-150K PV ISO-PRO01, Solis S6-EH3P75-150K PV ISO-PRO02
- Sungrow
- Sungrow SG200HX 1600-1615, Sungrow SG200HX 1632-1655, Sungrow SG250HX 1600-1615, Sungrow SG250HX 1632-1655, Sungrow SG350HX 1600-1615, Sungrow SG350HX 1632-1655
- Yaskawa Solectria
- Yaskawa Solectria SGI-XTM DC GND Fault, Yaskawa Solectria SGI-XTM RCM Fault, Yaskawa Solectria XGI-1500-1MW CRIT-7, Yaskawa Solectria XGI-1500 CRIT-7, Yaskawa Solectria XGI-1500-DCG CRIT-7
Claims
defined_in
c1 drafted · lead
Huawei SUN2000-100KTL-USH0 User Manual
has_event_class
c2 drafted · lead
Fault (device stops or needs intervention)
from the Type column
reports
c3 verified · fact
Ground fault alarm or trip
verified by: review-workflowverified on: 2026-10-23
affects
c4 drafted · lead
AC cable
detected_by
c5 drafted · lead
Insulation resistance testing
review note: support check: partial - Measures say to check impedance of phase wire to PE, which is akin to insulation/impedance checking, but no insulation resistance…
c6 verified · fact
Fault localization
verified by: review-workflowverified on: 2026-10-23
has_production_effect
c7 drafted · lead
Trip (production stops)
applies_to
c8 drafted · lead
Huawei SUN2000-100KTL-USH0
Data