FailureMode
Loss of electrical insulation
- ID
fm:insulation-loss
- IRI
https://solarlattice.org/kb/fm/insulation-loss
- Status
- active
- Also known as
- insulation fault, Insulation failure, isolation fault, low insulation resistance, Electrical insulation fault
Loss of electrical insulation means current-carrying parts of the PV array are no longer properly isolated from ground or from people. It usually comes from damaged cables, faulty connectors, broken module glass or failed junction boxes. Moisture makes it worse, so the fault may only appear during rain or humid periods and can be intermittent. In the field it shows up as ground faults and inverter trips or shutdowns. Low insulation resistance on its own does not reduce output until the inverter faults. If the leakage stays below the protection device thresholds, the fault can go undetected while still causing significant power losses. Confirm it with insulation resistance testing on isolated circuits. Treat it as a shock hazard: exposed parts can carry dangerous voltages, and in the worst case damaged cables or connectors can arc and start a fire. Replace damaged cable runs or modules that can no longer guarantee insulation, then confirm insulation integrity after the repair.
Claims
caused_by
c1 drafted · lead
Cable Defect
Damaged or undersized DC cables are named as a main source of insulation faults.
c2 verified · fact
Connector Defect
verified by: joshuahamsaverified on: 2026-10-20
c3 drafted · lead
Glass Breakage
Once the glass is broken, module insulation is no longer guaranteed, especially in wet conditions.
c4 verified · fact
Junction Box Failure
verified by: joshuahamsaverified on: 2026-10-20
c5 drafted · lead
Delamination
Delamination near the junction box or module edge can let water in, causing an insulation failure as a follow-up failure.
c6 drafted · lead
Moisture exposure
The fault can come and go with humidity and is often worse on rainy days or in humid periods.
review note: support check: partial - The passages tie moisture to insulation faults that are intermittent and worse in wet or humid periods, but they don't present moisture exposure as a generic cause.
affects
c7 drafted · lead
DC cable
c8 drafted · lead
DC connector
c9 drafted · lead
Junction box
presents_as
c10 drafted · lead
Ground fault alarm or trip
May be intermittent, with lower insulation during rain.
c11 drafted · lead
Inverter shutdown
Low insulation resistance causes no loss by itself until the inverter faults or switches off.
leads_to
c12 drafted · lead
Arc fault
In the worst case, damaged cables or connectors may arc and start a fire.
detected_by
c13 drafted · lead
Insulation resistance testing
mitigated_by
c14 drafted · lead
Module replacement
Replace modules that can no longer guarantee electrical safety or insulation resistance.
c15 drafted · lead
Cable replacement
c16 drafted · lead
Post-repair verification
Confirm insulation integrity after the repair.
c17 drafted · lead
Certified product selection