c1 drafted · lead FIMER PVS-60-TL-US Product Manual RevB
- FIMER PVS-60-TL-US Product Manual RevB
tbl=48.r3h=d76c0602229e
Fault codes › ABB / FIMER › FIMER PVS-60-TL-US
Reports low insulation resistance; may indicate loss of electrical insulation; look at PV array, junction box, DC connector, surge protection device; confirm with insulation resistance testing; do: proper junction box sealing, contact system installer, contact manufacturer service.
Failure modes that present as the reported condition, and the tests that tell them apart.
tbl=48.r3 h=d76c0602229eThe manufacturer's own cause and corrective text is not reproduced here.
defined_inc1 drafted · lead FIMER PVS-60-TL-US Product Manual RevB
tbl=48.r3 h=d76c0602229ehas_event_classc2 drafted · lead Fault (device stops or needs intervention)
from the code prefix
tbl=48.r3 h=d76c0602229ereportsc3 drafted · lead Low insulation resistance
tbl=55.r2 h=52c48bd40399tbl=48.r3 h=d76c0602229etbl=40.r7 h=c1518601ae36tbl=50.r1 h=4e3933871263tbl=39.r5 h=689ffa25ba76indicatesc4 drafted · lead Loss of electrical insulation
tbl=55.r2 h=52c48bd40399tbl=48.r3 h=d76c0602229etbl=40.r7 h=c1518601ae36affectstbl=55.r2 h=52c48bd40399tbl=48.r3 h=d76c0602229etbl=40.r7 h=c1518601ae36c6 drafted · lead Junction box
tbl=55.r2 h=52c48bd40399tbl=48.r3 h=d76c0602229etbl=40.r7 h=c1518601ae36c7 drafted · lead DC connector
tbl=55.r2 h=52c48bd40399tbl=48.r3 h=d76c0602229etbl=40.r7 h=c1518601ae36review note: support check: partial - The passages mention panel connections and cable joints, but not a DC connector specifically.
c8 drafted · lead Surge protection device
tbl=55.r2 h=52c48bd40399tbl=48.r3 h=d76c0602229etbl=40.r7 h=c1518601ae36has_production_effectc9 drafted · lead Trip (production stops)
Inverter does not connect while resistance is below 1 megaohm.
tbl=55.r2 h=52c48bd40399tbl=48.r3 h=d76c0602229etbl=40.r7 h=c1518601ae36detected_byc10 drafted · lead Insulation resistance testing
tbl=55.r2 h=52c48bd40399tbl=48.r3 h=d76c0602229etbl=40.r7 h=c1518601ae36mitigated_byc11 drafted · lead Proper junction box sealing
tbl=55.r2 h=52c48bd40399tbl=48.r3 h=d76c0602229etbl=40.r7 h=c1518601ae36review note: support check: partial - Improper junction box sealing is a listed cause, but the passages give no explicit remedy of sealing the box. They…
c12 drafted · lead Contact system installer
When measured resistance is below 1 megaohm.
tbl=55.r2 h=52c48bd40399tbl=48.r3 h=d76c0602229etbl=40.r7 h=c1518601ae36c13 drafted · lead Contact manufacturer service
When resistance is above 1 megaohm and the alarm persists.
tbl=55.r2 h=52c48bd40399tbl=48.r3 h=d76c0602229etbl=40.r7 h=c1518601ae36applies_toc14 drafted · lead FIMER PVS-60-TL-US string inverter
tbl=48.r3 h=d76c0602229e