Fault codes › Canadian Solar › CSI-125K-T600GL02-U
Canadian Solar 125K-T600GL02 PV-MID-ISO
- Code
PV-MID-ISO
- Page
- 36
- ID
fc:canadian-solar-125k-t600gl02-pvmidiso
- IRI
https://solarlattice.org/kb/fc/canadian-solar-125k-t600gl02-pvmidiso
- Status
- active
- Also known as
- PV-MID-ISO, pvmidiso, Canadian Solar PV-MID-ISO
- Category
- Inverters
Class
not stated
Production
not stated
Clears
not stated
Decoded
Reports low insulation resistance; look at DC connector, PV array disconnect switch; confirm with visual inspection; do: DC wiring check, external fuse check.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E025, ABB / FIMER PVS-166-175-TL E037, ABB / FIMER PVS-60-TL E025, ABB / FIMER PVS-60-TL E037, ABB / FIMER TRIO-20.0-27.6-TL E025, ABB / FIMER TRIO-20.0-27.6-TL E037, ABB / FIMER UNO-DM-3.3-5.0-PLUS E025, ABB / FIMER UNO-DM-6.0-PLUS E025
- CPS
- CPS SCA25KTL-208 IsolationErr, CPS SCA25KTL-480 IsolationErr, CPS SCA36KTL IsolationErr, CPS SCA50-100K-T Protect0190, CPS SCA50-60KTL IsolationErr, CPS SCH100-125KTL IsolationErr, CPS SCH125KTL-AIO IsolationErr, CPS SCH200-250K-T IsolationErr, CPS SCH275KTL IsolationErr, CPS SCH350KTL IsolationErr
- Canadian Solar
- Canadian Solar 125K-T600GL02 PV ISO-PRO 01/02, Canadian Solar 185-255K PV ISO-PRO 01/02, Canadian Solar 23-28KTL-CT IsolationErr, Canadian Solar 25-40K-T480GL01 PV ISO-PRO 01/02, Canadian Solar 50-66K-T480GL01 PV ISO-PRO 01/02, Canadian Solar 75-100K-T480GL02 PV ISO-PRO 01/02
- Enphase
- Enphase IQ7 DC Resistance Low - Power Off, Enphase IQ8 DC Resistance Low - Power Off, Enphase IQ9N DC Resistance Low - Power Off, Enphase M215-M250 DC Resistance Low - Power Off
- Fronius
- Fronius Galvo 502, Fronius Primo 447, Fronius Primo 502, Fronius Symo 447, Fronius Symo 502
- Huawei
- Huawei SUN2000-100KTL-USH0 2062, Huawei SUN2000-25-30KTL-US 313, Huawei SUN2000-45KTL-US-HV-D0 313
- KACO new energy
- KACO new energy blueplanet TL3 181, KACO new energy blueplanet TL3 182, KACO new energy blueplanet TL3 183
- SMA
- SMA SB-US-40 3501, SMA SB-US-41 3501, SMA SBSE-US-50 3501, SMA PEAK3-US 3501, SMA CORE1-US 3501, SMA STP-TL-US 3501, SMA STP-X-US 3501, SMA SC-CP-XT 3501, SMA SC-CP-XT 3504, SMA SC-CP-XT 3510, SMA SC-CP-XT 3511
- Schneider Electric
- Schneider Electric CL125 039, Schneider Electric CL125 055
- Solis
- Solis 1P-4G-US PV ISO-PRO 01/02, Solis 3P-5G-US PV ISO-PRO 01/02, Solis RHI-1P-HV PV ISO-PRO 01/02, Solis S5-GC PV ISO-PRO 01/02, Solis S6-EH1P PV ISO-PRO 01/02, Solis S6-GC PV ISO-PRO 01/02, Solis S6-GU PV ISO-PRO 01/02
- Sungrow
- Sungrow SG-CX-US 039, Sungrow SG200HX 039, Sungrow SG250HX 39, Sungrow SG350HX 039
- Yaskawa Solectria
- Yaskawa Solectria PVI-25TL-R IsolationErr, Yaskawa Solectria PVI-TL IsolationErr
Claims
defined_in
c1 drafted · lead
CSI User Manual 125K-T600GL02-U NA V1.1 20210518
reports
c2 drafted · lead
Low insulation resistance
affects
c3 verified · fact
DC connector
verified by: review-workflowverified on: 2026-10-23
c4 drafted · lead
PV array disconnect switch
review note: support check: partial - The external DC switch is only listed among items to physically check, not stated as the affected component.
detected_by
c5 drafted · lead
Visual inspection
review note: support check: partial - Physical checking of connectors is the solution step, not stated as a detection method; the inverter detects it.
mitigated_by
c6 drafted · lead
DC wiring check
c7 drafted · lead
External fuse check
applies_to
c8 drafted · lead
CSI-125K-T600GL02-U
Data