Solar Lattice

FailureMode

Backsheet Cracking

ID
fm:backsheet-cracking
IRI
https://solarlattice.org/kb/fm/backsheet-cracking
Status
active
Also known as
PVFS 1-5
Category
Modules

Backsheet cracking is any crack, burst or scratch in the module backsheet. It can affect only the surface or the whole layer stack. Causes include UV, thermal and mechanical stress, handling damage during transport or installation, poor-quality or mismatched materials, and local overheating from hot cells or hotspots. Cracks may be local, run along busbars or between cells, or cover the whole rear surface. Browning or bubbles may appear where a hot cell caused them. Deep cracks break the electrical insulation. This creates a safety hazard and possible ground faults, and it is worst in wet conditions. Over time, moisture that gets in through the cracks can cause corrosion and delamination, which lower power output. Confirm the failure with a visual inspection of the rear side, followed by insulation testing or wet-leakage testing. Replace modules that pose a direct safety risk or fail insulation or wet-leakage tests, and keep inspecting the modules that stay in service. To prevent it, keep ground fault detection running, check certification and the bill of materials, and inspect modules before installation.

<!-- review notes

Claims

affects

c1 drafted · lead Backsheet

caused_by

c2 verified · fact UV exposure

Weak UV stabilisation of the outer layer leads to photo-oxidation and surface microcracks (type I).

verified by: joshuahamsaverified on: 2026-10-20

c3 drafted · lead Thermal cycling

Thermal cycling drives microcracks to grow into macrocracks in polyamide backsheets.

c4 drafted · lead Mechanical stress

Includes external loads and internal stress built in during lamination at busbar positions, plus thermal-expansion mismatch.

c5 drafted · lead Transport damage

Careless handling can leave local cuts and scratches.

c6 drafted · lead Installation error

Careless handling during installation can leave cuts and scratches.

c7 drafted · lead Low-quality material

For example, low UV resistance. The sources name this as a main cause of early failures.

c8 drafted · lead Material incompatibility

Backsheet and encapsulant that do not suit each other.

c9 drafted · lead Acetic acid release

Acid from EVA attacks the backsheet's inner layer between cells and weakens it (squared cracks).

c10 drafted · lead Humid climate

Hot, humid conditions make cracking and the damage that follows more frequent and more severe.

review note: support check: partial - Passages say backsheet cracking followed by moisture ingress and corrosion is more frequent and severe in hot, humid conditions. They do not clearly say humidity causes the cracking itself.

c11 verified · fact Hot cell

Local overheating from hot cells breaks down the backsheet chemically, and it then cracks locally (type II).

verified by: joshuahamsaverified on: 2026-10-20

c12 drafted · lead Module Hotspot from Cell Damage

Hotspots or burn marks can split the backsheet or burst bubbles in it.

c13 drafted · lead Backsheet Chalking

Chalking may come before cracking, but it is not a reliable predictor. Cracks also appear without chalking.

review note: support check: partial - Chalking can be a precursor and cracks occur with and without chalking, but the passages treat chalking as a photo-oxidative co-symptom, not a cause.

presents_as

c14 drafted · lead Visible backsheet cracks

Cracks, bursts or scratches. They can be local, run along busbars or between cells, or cover the whole surface.

c15 drafted · lead Ground fault alarm or trip

review note: support check: partial - A broken backsheet can cause a potential ground fault, but the passages do not say it presents as an alarm or trip.

c16 verified · fact Yellow to brown discoloration

Browning often accompanies cracks caused by overheating.

verified by: joshuahamsaverified on: 2026-10-20

c17 verified · fact Backsheet bubbles or ripples

Burst bubbles or gas formation from local overheating.

verified by: joshuahamsaverified on: 2026-10-20

leads_to

c18 drafted · lead Loss of electrical insulation

Insulation resistance can collapse when the backsheet is cracked through, especially when wet.

c19 drafted · lead Delamination

Moisture gets in through the cracks.

c20 verified · fact Severe Metallization Corrosion

Deep cracks are often followed by moisture ingress and corrosion.

verified by: joshuahamsaverified on: 2026-10-20

detected_by

c21 drafted · lead Visual inspection

c22 drafted · lead Insulation resistance testing

c23 drafted · lead Wet leakage current test

review note: support check: partial - Wet-leakage test is mentioned only as a criterion for module replacement, not explicitly as a detection method.

c24 drafted · lead Optical profilometry

A research method that used machine learning on surface scans. It found cracks before they could be seen.

mitigated_by

c25 drafted · lead Module replacement

Replace modules with a direct safety risk or that fail insulation or wet-leakage tests. Squared cracks require replacing every module with the same BOM.

c26 drafted · lead Backsheet repair coating

A suitable coating or film may repair longitudinal cracks. Squared cracks cannot be repaired.

c27 drafted · lead Continuous ground fault detection

c28 drafted · lead Certified product selection

Check that the IEC 61215 certification is valid.

c29 drafted · lead Bill of materials verification

c30 verified · fact Pre-installation visual inspection

verified by: joshuahamsaverified on: 2026-10-20

c31 drafted · lead Regular system inspections

c32 drafted · lead Arc fault circuit interrupter

Installing an arc detection tool is listed as an optional preventive action.

c33 drafted · lead Accelerated weathering screening

Weathering tests followed by wipe tests, run as a preventive screen.