Regular system inspections
Regular system inspections are a preventive action, listed as optional, for module, mounting and cabling failures such as backsheet cracking, backsheet chalking, cable insulation failure, bad module clamping and defective mounting structures. Where modules or cables that pose a direct safety risk are replaced, regular inspections are used to track the condition of the parts left in service. For backsheet chalking, inspections follow how the observed degradation progresses, because chalking can come before more serious backsheet cracking. For bad clamping and defective mounting structures, inspections go together with accredited laboratory testing of non-standard mounting setups such as facade mounting. For inverter overheating and incorrect inverter installation, inspections focus on the ventilation units, together with following the installation procedure and using adequate cooling. These failures are mainly found by visual inspection; for inverter installation faults, monitoring is also used. Inspections only find and track problems and do not fix them, so the sources pair them with continuous ground fault detection and, in newer guidance, an arc detection tool.
<!-- review notes
- sentence 1: support check: partial - Regular inspections appear in the optional preventive column for mounting structures and chalking/cracking entries, but the passages show the optional column explicitly only for mounting structure and don't clearly label it for all listed failures (e.g. clamping's optional entry is combined with lab testing, insulation failure is not tabulated).
- sentence 5: support check: partial - Passages say to follow installation procedure, use adequate cooling and regularly inspect ventilation units, but 'inspections focus on ventilation units' is a slight reframing of a list of preventive actions; core is supported.
- sentence 6: support check: partial - Detection is VI for cracking, clamping, mounting structure and VI (MON) for incorrect installation, but chalking, cables and overheating detection are not shown, and 'mainly' is a generalization.
- sentence 7: support check: partial - Ground fault detection and arc detection tool (in vs.02) are paired with inspections, but the claim that inspections only find/track and don't fix is not stated, and arc detection is not paired for all cases. -->
Referenced by
- Backsheet Cracking
mitigated_byc31 - Inverter Incorrect Installation
mitigated_byc9 - Inverter Overheating
mitigated_byc16 - Bad Module Clamping
mitigated_byc13 - Defective Mounting Structure
mitigated_byc21 - Electric shock
controlled_byc3 - Electrical fire
controlled_byc8