FailureMode
Defective Mounting Structure
- ID
fm:mounting-structure-defect
- IRI
https://solarlattice.org/kb/fm/mounting-structure-defect
- Status
- active
- Also known as
- PVFS 3-2, Inappropriate/defect mounting structure, PVFS 3-2vs.01
- Category
- Mounting
A defective mounting structure was either never right for the site or has failed. Common causes are design for too little wind or snow load, weak anchoring to the ground or roof, unsuitable or corroding materials, and installation errors. Look for bent or cracked members and for corrosion on the frame or around the mounting holes. Visual inspection is the detection method. Where aluminium and steel touch, check the fastening screws for galvanic corrosion, especially at humid or coastal sites. In those areas the two metals need insulation between them. A failing structure can damage the modules, causing broken glass, cracked cells and damaged junction boxes. In the worst case modules or the whole structure come loose, or the roof collapses, which is a serious danger to people. Replace or repair any structure that poses a direct safety risk. To prevent this failure, use compatible structures, follow the manufacturer's mounting instructions, check local wind and snow loads, and inspect the system regularly. Non-standard configurations should be tested by an accredited laboratory.
<!-- review notes
- sentence 4: support check: partial - Insulation requirement and galvanic corrosion near screws are stated, but an explicit instruction to check screws is not.
-->
Claims
caused_by
c1 verified · fact
High winds
The structure was not designed for the wind loads typical of the site, for example when it does not match the static calculations.
verified by: joshuahamsaverified on: 2026-10-20
c2 drafted · lead
Heavy snowfall
The structure was not designed for the snow loads typical of the site, or the environmental conditions were underestimated.
c3 drafted · lead
Weak structural anchorage
Weak anchoring to the ground or roof, for example when ground conditions were not considered enough while choosing the structure. Roof strength for the added load and O&M work may also be left unchecked.
c4 verified · fact
Low-quality material
Examples are corrosive materials in a corrosive environment, too little galvanisation, or poor material from weak quality assurance. These lead to early degradation or mechanical failure.
verified by: joshuahamsaverified on: 2026-10-20
c5 drafted · lead
Installation error
Examples are missing or non-original components and screws tightened too much or too little.
c6 drafted · lead
Dissimilar metal contact
Galvanic corrosion where two different metals touch, such as an aluminium frame on a steel structure. It often occurs around fastening screws.
c7 verified · fact
Humid climate
Galvanic corrosion matters most in humid or coastal areas.
verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - Passages say galvanic corrosion matters in humid or coastal areas, but don't frame humid climate as a cause of the defect generally.
affects
c8 drafted · lead
Mounting structure
c9 drafted · lead
Module frame
Corrosion of the frame or mounting holes can be seen. A damaged structure also compromises the integrity of the modules mounted on it.
review note: support check: partial - Corrosion of frame and compromised module integrity are stated, but the frame mentioned is on the mounting structure, not clearly the module frame.
c10 drafted · lead
Roof substructure
The substructure, such as roof insulation, can be compromised. In the worst case the roof collapses.
presents_as
c11 drafted · lead
Bent or cracked structure
c12 drafted · lead
Visible corrosion marks
Corrosion of the frame or the mounting holes.
detected_by
c13 drafted · lead
Visual inspection
leads_to
c14 drafted · lead
Glass Breakage
c15 drafted · lead
Cell Cracks
c16 verified · fact
Junction Box Failure
The junction box may be damaged or detached.
verified by: joshuahamsaverified on: 2026-10-20
mitigated_by
c17 drafted · lead
Structural hardware repair
Corrective action: replace or repair any structure that poses a direct safety risk.
c18 drafted · lead
Compatible mounting structure
The ground, the mounting structure and the modules must be compatible with each other.
c19 drafted · lead
Proper installation
Follow the manufacturer's mounting instructions.
c20 verified · fact
Site wind and snow load check
verified by: joshuahamsaverified on: 2026-10-20
c21 drafted · lead
Regular system inspections
c22 drafted · lead
Mounting configuration testing
An accredited laboratory tests non-standard configurations, such as facade mounting.
c23 drafted · lead
Dissimilar metal insulation
Required in humid and coastal areas.