A defective mounting structure was either never right for the site or has failed. Common causes are design for too little wind or snow load, weak anchoring to the ground or roof, unsuitable or corroding materials, and installation errors. Look for bent or cracked members and for corrosion on the frame or around the mounting holes. Visual inspection is the detection method. Where aluminium and steel touch, check the fastening screws for galvanic corrosion, especially at humid or coastal sites. In those areas the two metals need insulation between them. A failing structure can damage the modules, causing broken glass, cracked cells and damaged junction boxes. In the worst case modules or the whole structure come loose, or the roof collapses, which is a serious danger to people. Replace or repair any structure that poses a direct safety risk. To prevent this failure, use compatible structures, follow the manufacturer's mounting instructions, check local wind and snow loads, and inspect the system regularly. Non-standard configurations should be tested by an accredited laboratory.

<!-- review notes

Claims

caused_by

c1 verified · fact High winds

The structure was not designed for the wind loads typical of the site, for example when it does not match the static calculations.

verified by: joshuahamsaverified on: 2026-10-20

c2 drafted · lead Heavy snowfall

The structure was not designed for the snow loads typical of the site, or the environmental conditions were underestimated.

c3 drafted · lead Weak structural anchorage

Weak anchoring to the ground or roof, for example when ground conditions were not considered enough while choosing the structure. Roof strength for the added load and O&M work may also be left unchecked.

c4 verified · fact Low-quality material

Examples are corrosive materials in a corrosive environment, too little galvanisation, or poor material from weak quality assurance. These lead to early degradation or mechanical failure.

verified by: joshuahamsaverified on: 2026-10-20

c5 drafted · lead Installation error

Examples are missing or non-original components and screws tightened too much or too little.

c6 drafted · lead Dissimilar metal contact

Galvanic corrosion where two different metals touch, such as an aluminium frame on a steel structure. It often occurs around fastening screws.

c7 verified · fact Humid climate

Galvanic corrosion matters most in humid or coastal areas.

verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - Passages say galvanic corrosion matters in humid or coastal areas, but don't frame humid climate as a cause of the defect generally.

affects

c8 drafted · lead Mounting structure

c9 drafted · lead Module frame

Corrosion of the frame or mounting holes can be seen. A damaged structure also compromises the integrity of the modules mounted on it.

review note: support check: partial - Corrosion of frame and compromised module integrity are stated, but the frame mentioned is on the mounting structure, not clearly the module frame.

c10 drafted · lead Roof substructure

The substructure, such as roof insulation, can be compromised. In the worst case the roof collapses.

presents_as

c11 drafted · lead Bent or cracked structure

c12 drafted · lead Visible corrosion marks

Corrosion of the frame or the mounting holes.

detected_by

c13 drafted · lead Visual inspection

leads_to

c14 drafted · lead Glass Breakage

c15 drafted · lead Cell Cracks

c16 verified · fact Junction Box Failure

The junction box may be damaged or detached.

verified by: joshuahamsaverified on: 2026-10-20

mitigated_by

c17 drafted · lead Structural hardware repair

Corrective action: replace or repair any structure that poses a direct safety risk.

c18 drafted · lead Compatible mounting structure

The ground, the mounting structure and the modules must be compatible with each other.

c19 drafted · lead Proper installation

Follow the manufacturer's mounting instructions.

c20 verified · fact Site wind and snow load check

verified by: joshuahamsaverified on: 2026-10-20

c21 drafted · lead Regular system inspections

c22 drafted · lead Mounting configuration testing

An accredited laboratory tests non-standard configurations, such as facade mounting.

c23 drafted · lead Dissimilar metal insulation

Required in humid and coastal areas.