FailureMode
Severe Metallization Corrosion
- ID
fm:severe-metallization-corrosion
- IRI
https://solarlattice.org/kb/fm/severe-metallization-corrosion
- Status
- active
- Category
- Modules
Severe metallization corrosion is the chemical attack of a cell's busbars and interconnect ribbons after water and oxygen get into the module. Heat and moisture break down the encapsulant, usually EVA, which releases acetic acid that corrodes the metal. Delamination, a poor backsheet, broken glass and PID can all speed this up. Some corrosion is normal over a module's life, but advanced corrosion can sharply cut module power. Damp-heat tests found losses of up to 80% in the worst case. Corrosion is usually easy to spot visually. Electroluminescence images also show it. On an IV curve it shows as a lower fill factor from higher series resistance, along with a lower short-circuit current. Thermography also helps confirm the electrical impact. Because corrosion is often uneven, it can cause mismatch and hotspots, overwork bypass diodes and weaken cell interconnections. Replace severely corroded modules, find out where the water is getting in, and choose module designs and installation practices that limit moisture exposure.
<!-- review notes
- sentence 1: support check: partial - Passages say corrosion starts with water/oxygen ingress and attacks busbars and ribbons, but 'chemical attack' framing is roughly implied via acetic acid; mostly supported.
-->
Claims
caused_by
c1 drafted · lead
Moisture exposure
Water and oxygen getting into the module start the corrosion process.
c2 drafted · lead
Acetic acid release
Acetic acid forms when the encapsulant, usually EVA, hydrolyses in the presence of heat and water.
c3 drafted · lead
High operating temperature
Heat drives encapsulant hydrolysis. How sensitive the encapsulant is to heat is a key factor.
c4 drafted · lead
UV exposure
UV stress was considered a possible factor that helps acetic acid form.
c5 drafted · lead
Delamination
Delamination lets water move into the module layers and often sets off encapsulant degradation.
c6 verified · fact
Discoloration
Degraded encapsulant shows yellowing before it promotes corrosion through acetic acid release.
verified by: joshuahamsaverified on: 2026-10-16
c7 drafted · lead
Glass Breakage
Broken glass lets water in and speeds up corrosion.
c8 drafted · lead
Potential Induced Degradation (PID)
PID can raise corrosion levels through its own mechanisms.
affects
c9 drafted · lead
Solar cell
The corrosion attacks the cell busbars and metal grid.
c10 drafted · lead
Cell interconnect ribbon
Ribbons are attacked, and corrosion weakens the cell interconnections.
presents_as
c11 drafted · lead
Increased series resistance
c12 verified · fact
Reduced fill factor
verified by: joshuahamsaverified on: 2026-10-16
c13 drafted · lead
Reduced short-circuit current
c14 verified · fact
Visible corrosion marks
Corrosion is easy to see during visual inspection.
verified by: joshuahamsaverified on: 2026-10-16
detected_by
c15 drafted · lead
Visual inspection
Look for corrosion and damage to the encapsulation.
c16 drafted · lead
Electroluminescence imaging
c17 drafted · lead
IV curve tracing
The IV curve shows a lower fill factor because series resistance rises, plus a lower Isc.
c18 verified · fact
Infrared thermography
verified by: joshuahamsaverified on: 2026-10-16
leads_to
c19 drafted · lead
Module Hotspot from Cell Damage
Corrosion is often uneven across the module, which creates mismatch and possible hotspots.
c20 verified · fact
Bypass Diode Failure
Mismatch can switch on bypass diodes, and running longer than intended speeds up their ageing.
verified by: joshuahamsaverified on: 2026-10-16
c21 verified · fact
Cell Interconnection Failure
Weakened interconnections can fail from fatigue, with brown marks.
verified by: joshuahamsaverified on: 2026-10-16
mitigated_by
c22 drafted · lead
Module replacement
Applies to severely corroded modules.
c23 drafted · lead
Root cause investigation
Find out why water is getting in.
c24 verified · fact
Moisture-resistant module design
Favour module designs that limit moisture exposure.
verified by: joshuahamsaverified on: 2026-10-16
c25 drafted · lead
Proper installation
Favour installation practices that limit moisture exposure.
typical_power_loss
c26 drafted · lead
≤ 80 PERCENT
Conditions: Worst-case drop in module maximum power from corrosion caused by water ingress, seen in damp-heat tests
review note: support check: partial - 80% is stated as a worst-case drop in damp-heat tests, not a typical value.