Symptom
Reduced short-circuit current
- ID
symptom:isc-reduction
- IRI
https://solarlattice.org/kb/symptom/isc-reduction
- Status
- active
- Also known as
- Isc
Reduced short-circuit current shows up when a string's Isc is measured with a short-circuit test. Compare it with the expected value and with identical strings under stable irradiance. On an IV trace, look at the other parameters too. Metallization corrosion lowers Isc and fill factor because series resistance rises, while LID lowers Isc, fill factor and Voc together. PID-p causes a significant drop in Isc, Voc and power. PID-s mainly reduces fill factor and affects Isc only when it is far advanced. Cell cracks reduce current because isolated cell areas stop contributing. EL imaging shows microcracks that cannot be seen by eye. Most cracks do not isolate cell parts and cause little power loss. A large inactive area can reverse-bias the cell or switch on the bypass diode. Soiling also lowers Isc. Soiling stations measure it by comparing a regularly cleaned reference device with a soiled one, using temperature-corrected Isc. Uneven soiling can cost more power than the change in Isc suggests, so record power as well as Isc. First check whether the module surface is soiled or the cells are visibly corroded. Then use IV tracing, EL and thermography to tell cracks, corrosion, LID and PID apart.
<!-- review notes
- sentence 6: support check: partial - Measurement method with clean reference and temperature-compensated Isc is stated, but the passages do not explicitly state that soiling lowers Isc, only implicitly via the soiling ratio.
- sentence 8: support check: partial - Visual inspection for corrosion then IV, EL, thermography is supported, but checking soiled surface first and using these to tell cracks, corrosion, LID and PID apart is only partly stated.
-->
Claims
observed_as
c1 drafted · lead
Low string short-circuit current
In a string short-circuit test, measured string Isc is compared with the expected value and with identical strings under stable irradiance; the standard expects identical strings to agree typically within 5 % of the average. The test is meant to detect faults, not to rate performance.
c2 verified · fact
Lowered Isc on IV curve
Shown in IV traces for metallization corrosion, LID, PID-p and cracks that isolate part of a cell.
verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - Corrosion, LID and PID-p lowering Isc are stated, but cracks lowering Isc is not stated in the IV context here (only EL-based mention elsewhere); the IV-trace attribution for cracks is missing.
c3 verified · fact
Reduced fill factor
Occurs together with lower Isc in metallization corrosion (higher series resistance) and in LID.
verified by: joshuahamsaverified on: 2026-10-20
c4 verified · fact
Low open-circuit voltage
LID and PID-p lower Voc along with Isc, while cracks and soiling mainly lower current.
verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - LID and PID-p lowering Voc with Isc is stated, but the claim that cracks and soiling mainly lower current is not supported for Voc comparison in these passages.
c5 drafted · lead
Soiled vs clean Isc ratio
Soiling stations take the soiling ratio from the temperature-compensated Isc of a regularly cleaned device and a soiled one. Data are usually filtered to clear-sky midday hours.
c6 verified · fact
Crack pattern in EL image
Microcracks that cannot be seen by eye show up in EL images and can isolate cell regions, which lowers Isc.
verified by: joshuahamsaverified on: 2026-10-20
c7 drafted · lead
Patchwork EL pattern
Growing non-uniformity in EL can point to ongoing LID. PID also shows patchwork patterns.
review note: support check: partial - Patchwork EL non-uniformity for LID is stated, but PID patchwork is mentioned only for IRT patterns, not EL.
typical_power_loss
c8 verified · fact
≤ 30 PERCENT
Conditions: Light induced degradation (light soaking effect), module power
verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - Passage says LID could entail losses up to 30% in module power performance, but not specifically as Isc reduction or typical value; 'up to' is a bound.; reviewer: the compiler-flagged conflict is a different scenario or technology, not disagreement
c9 disputed
1–3 PERCENT
Conditions: LID (boron-oxygen) in c-Si modules, first days of sun exposure
conflicts with: Reduced short-circuit current (c11)conflicts with: Reduced short-circuit current (c12)conflicts with: Reduced short-circuit current (c13)
c10 disputed
≤ 10 PERCENT
Conditions: LeTID, mainly PERC modules, over years at elevated temperature; adds to the LID loss
conflicts with: Reduced short-circuit current (c11)conflicts with: Reduced short-circuit current (c12)
c11 verified · fact
≥ 20 PERCENT
Conditions: PID yield losses observed within 1 year
verified by: joshuahamsaverified on: 2026-10-20review note: reviewer: the compiler-flagged conflict is a different scenario or technology, not disagreement
c12 verified · fact
nominal 35 PERCENT
Conditions: Simulated module with one cracked cell at 45 % inactive area, which activates the substring bypass diode
verified by: joshuahamsaverified on: 2026-10-20review note: possible conflict with c13 (same source; check the conditions); reviewer: the compiler-flagged conflict is a different scenario or technology, not disagreement
c13 verified · fact
nominal 5 PERCENT
Conditions: Simulated module with one cracked cell at 15 % inactive area
verified by: joshuahamsaverified on: 2026-10-20review note: possible conflict with c12 (same source; check the conditions); reviewer: the compiler-flagged conflict is a different scenario or technology, not disagreement
degradation_rate
c14 drafted · lead
≤ 3 PERCENT-PER-YR
Conditions: Cell cracks, global rate in all climate zones except cold and snowy ones
review note: possible conflict with c15 (same source; check the conditions)
c15 verified · fact
nominal 8 PERCENT-PER-YR
Conditions: Cell cracks, affected part, cold and snowy climate zones
verified by: joshuahamsaverified on: 2026-10-20review note: possible conflict with c14 (same source; check the conditions)