Symptom

Increased series resistance

ID
symptom:series-resistance-increase
IRI
https://solarlattice.org/kb/symptom/series-resistance-increase
Status
active
Also known as
Rs, resistance in series, serial resistance, high resistance faults

On an IV curve, increased series resistance makes the section between the maximum power point and Voc less steep. It also shows up as a lower fill factor and a more rounded knee. At array level, check first for damaged or undersized cables and for poor connections at module or array interconnects. A long cable run can produce the same curve shape, so repeat the trace closer to the array if you suspect this. Inside the module, the extra resistance can come from failing cell interconnects or junction box connections, from metallization corrosion, or from cell cracks. An infrared scan helps locate high-resistance faults. Defective connectors and poorly soldered interconnects show up as local heating, even before the electrical change can be measured. Corrosion is often visible to the eye and comes with a lower Isc. Interconnect failures and cracks are hard to see, so use EL imaging to find dark regions or crack lines. With cracked cells, most of the power loss comes from lost current rather than from series resistance.

<!-- review notes

Claims

observed_as

c1 verified · fact Shallow IV slope near Voc

Higher series resistance makes the IV curve less steep between Vmpp and Voc. Long cable runs can produce the same shape, so the model should account for them or the test should be repeated closer to the array.

verified by: joshuahamsaverified on: 2026-10-20

c2 verified · fact Reduced fill factor

Seen with metallization corrosion (together with lower Isc), with early-stage interconnect failure and with cell cracking.

verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - Corrosion with lower Isc and interconnect failure with fill factor decrease are stated, but cell cracking is only described with a 2% absolute FF drop, and 'early-stage' interconnect failure is only loosely matched (stage 1).

c3 verified · fact Rounded IV curve knee

Reported for interconnection failures where redundant interconnects still carry the current.

verified by: joshuahamsaverified on: 2026-10-20

c4 verified · fact Reduced Vmp/Voc ratio

In cracked-cell modules, a falling Vmp/Voc ratio points to series resistance. Light and dark IV curves, or light IV curves at two intensities, measure it best.

verified by: joshuahamsaverified on: 2026-10-20

c5 drafted · lead Hot electrical connection

In the first phase of a connector failure, extra resistance produces heat that thermography can show, even when the electrical change is too small to detect.

c6 drafted · lead Localized IR hotspot

Poor solder bonds in cell interconnects dissipate more power and heat up locally.

typical_power_loss

c7 disputed nominal 0.1 PERCENT

Conditions: Per cut cell interconnection in cells with 4 busbars, from a series resistance increase of about 1%

review note: possible conflict with c8 (same source; check the conditions)conflicts with: Increased series resistance (c9)

c8 disputed nominal 1 PERCENT

Conditions: Per cut cell interconnection in cells with 3 busbars (less redundancy)

review note: possible conflict with c7 (same source; check the conditions)conflicts with: Increased series resistance (c9)

c9 verified · fact nominal 2.6 PERCENT

Conditions: Part of a 10% module power loss from induced cell cracking that is caused by a series resistance increase of 0.5 Ohm cm2

verified by: joshuahamsaverified on: 2026-10-20review note: reviewer: the compiler-flagged conflict is a different scenario or technology, not disagreement