Solar Lattice

Concept

TOPCon cell

ID
concept:topcon
IRI
https://solarlattice.org/kb/concept/topcon
Status
active
Also known as
TOPCon, tunnel oxide passivated contact
Category
Modules
Concept kind
technology

TOPCon stands for tunnel oxide passivated contact. It is an advanced crystalline silicon cell design, usually built on n-type wafers. Like heterojunction cells, it cuts recombination at the contacts. This gives a higher open-circuit voltage without lowering the fill factor. TOPCon is expected to become the dominant cell technology after 2025, and cell designs change about every six months. Because of this, the limited field data on TOPCon may not represent the modules being built today. The front contacts use a glass-frit metal paste that is fired through the passivation and the anti-reflective coating, the same method used on PERC cells. When the cells are laminated in EVA and moisture gets in, acetic acid from the EVA can corrode the front metallization and the interconnects. TOPCon has been reported to be even more sensitive to this than PERC. In damp-heat testing, power loss in TOPCon modules depended strongly on the encapsulant. Using TPO encapsulants helped limit the loss.

<!-- review notes

Claims

subclass_of

c1 verified · fact Crystalline silicon PV

Described as an advanced c-Si cell architecture, typically on n-type wafers.

verified by: review-workflowverified on: 2026-10-24

related_to

c2 drafted · lead Heterojunction cell

Both are advanced c-Si architectures that reach higher Voc by minimising contact recombination without reducing fill factor.

c3 drafted · lead PERC cell

Both use glass-frit front metal pastes fired through the passivation; TOPCon was reported more susceptible to front contact corrosion than PERC.

c4 drafted · lead Severe Metallization Corrosion

TOPCon front metal contacts and interconnects can corrode at the metal/Si interface, with sensitivity likely linked to high aluminium content in the front paste.

review note: support check: partial - Corrosion at metal/Si interface and high Al content link are stated, but 'severe' metallization corrosion as a named failure mode isn't explicitly stated; it's generic corrosion.

c5 verified · fact Acetic acid release

Acetic acid from EVA decomposition in the presence of moisture drives front contact corrosion; TOPCon cells showed a larger contact resistivity increase under acetic acid exposure than PERC and SHJ.

verified by: review-workflowverified on: 2026-10-24

c6 drafted · lead Alternative encapsulant material

Use of TPO encapsulants was shown to mitigate power loss in 1000 h damp heat.

c7 verified · fact Fill factor

Higher Voc is achieved without reducing fill factor.

verified by: review-workflowverified on: 2026-10-24

typical_power_loss

c8 drafted · lead 4–65 PERCENT

Conditions: Maximum power loss (relative) of encapsulated TOPCon modules after 1000 h damp-heat testing across seven encapsulant/backsheet combinations; strongly dependent on encapsulation material (Sen et al.). PERC modules in the same study lost 1 to 2 %rel.

Referenced by