Solar Lattice

Stressor

UV exposure

ID
stressor:uv-exposure
IRI
https://solarlattice.org/kb/stressor/uv-exposure
Status
active
Also known as
UV, Ultraviolet, Ultra Violet, UV radiation, UV irradiation

UV exposure means the ultraviolet part of sunlight hitting the plant. It is only a small share of global irradiation, and its strength depends on climate and altitude, with higher annual doses at high-elevation sites. UV breaks down polymers such as EVA encapsulant and backsheets. This shows up as yellowing or browning of the encapsulant, along with power loss. UV can also weaken the bond between the encapsulant and the glass, which can lead to delamination. This can happen on its own or as a secondary effect after the encapsulant becomes brittle. In modern TOPCon, heterojunction and PERC cells, UV can damage the cell surface passivation. This UV-induced degradation lowers current or voltage. Exposed DC cables can crack when their insulation degrades under UV, even when the cable is certified for UV. This can cause insulation faults, and the cable then has to be replaced. Damage builds up faster when high UV comes with high module temperature, which is why hot, arid sites carry more risk. To reduce exposure, protect exposed wiring from sunlight. Choose modules whose antireflective coating, glass, encapsulant or passivation layers reflect or absorb UV before it reaches the cell.

<!-- review notes

Claims

typical_power_loss

c1 verified · fact 0.5–8, nominal 3 PERCENT

Conditions: 14 TOPCon module types after an accelerated UV dose of 60 kWh/m² under short-circuit conditions (Gebhardt et al.); nominal is the median

The authors say a 60 kWh/m² dose matches about 1 to 2 years outdoors, depending on location. Field loss may be lower because modules run at maximum power point, not short circuit.

verified by: joshuahamsaverified on: 2026-10-20

c2 verified · fact 0–10 PERCENT

Conditions: 28 TOPCon module types after an accelerated UV dose of 60 kWh/m² under short-circuit conditions (Shina)

verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - Passage gives 0-10% for 28 TOPCon at 60 kWh/m² short-circuit, but it is a range with no stated typical/median value.

c3 verified · fact 1–2.5 PERCENT

Conditions: 2 SHJ module types after an accelerated UV dose of 60 kWh/m² under short-circuit conditions (Shina)

verified by: joshuahamsaverified on: 2026-10-20review note: reviewer: the compiler-flagged conflict is a different scenario or technology, not disagreement

c4 verified · fact ≥ 5 PERCENT

Conditions: Some monocrystalline modules after long-term indoor UV exposure of 150 kWh/m² or more, often together with EVA browning

In one test, one of five modules lost more than 5% after 160 kWh/m². No module reached 5% at the 15 kWh/m² IEC 61215 dose.

verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - Passage supports >5% for one of five modules at 160 kWh/m², <5% at 15 kWh/m², and EVA browning; but 'some modules' at 150+ is potential, and the 'indoor' 160 test is single-module, so 'at least 5%' typical is overstated.; reviewer: the compiler-flagged conflict is a different scenario or technology, not disagreement