Fault codes › SMA › Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40)
Reports ground fault alarm or trip; look at PV array; confirm with insulation resistance testing, open-circuit voltage measurement, grid voltage measurement, visual inspection, infrared thermography; do: grounding conductor check, DC wiring check.
Failure modes that present as the reported condition, and the tests that tell them apart.
sec=h209 h=21872bbd9f73sec=h210 h=dba4882bde4cThe manufacturer's own cause and corrective text is not reproduced here.
defined_inc1 drafted · lead SBxx-US-1XP-40-BA-en-13
sec=h209 h=21872bbd9f73sec=h210 h=dba4882bde4creportsc2 drafted · lead Ground fault alarm or trip
tbl=18.r1 h=a1fc2477c9aetbl=7.r1 h=a1fc2477c9aetbl=19.r1 h=3287c94f0288sec=h210 h=dba4882bde4csec=h285 h=9e1658bb50c5affectstbl=18.r1 h=a1fc2477c9aetbl=7.r1 h=a1fc2477c9aetbl=19.r1 h=3287c94f0288sec=h210 h=dba4882bde4cdetected_byc4 drafted · lead Insulation resistance testing
sec=11.1.20 h=1fc05755d2d4sec=h467 h=10a07fe57d31c5 drafted · lead Open-circuit voltage measurement
sec=11.1.20 h=1fc05755d2d4sec=h467 h=10a07fe57d31c6 drafted · lead Grid voltage measurement
sec=11.1.20 h=1fc05755d2d4sec=h467 h=10a07fe57d31c7 drafted · lead Visual inspection
sec=11.1.20 h=1fc05755d2d4sec=h467 h=10a07fe57d31c8 drafted · lead Infrared thermography
sec=11.1.20 h=1fc05755d2d4sec=h467 h=10a07fe57d31review note: support check: partial - IR camera is mentioned only as a tip for support, not as a definite detection method.
mitigated_byc9 drafted · lead Grounding conductor check
sec=11.1.20 h=1fc05755d2d4sec=h467 h=10a07fe57d31c10 drafted · lead DC wiring check
tbl=19.r1 h=3287c94f0288sec=h286 h=3450f514b95fsec=h573 h=0818fdbe4234has_event_classc11 drafted · lead Fault (device stops or needs intervention)
sec=11.1.20 h=1fc05755d2d4sec=h466 h=ceee8640eb7creview note: support check: partial - Describes an insulation error with auto reconnect; fault class is only loosely implied, not stated.
has_production_effectc12 drafted · lead Trip (production stops)
Momentary insulation error; inverter disconnects and reconnects.
sec=11.1.20 h=1fc05755d2d4sec=h466 h=ceee8640eb7creview note: support check: partial - The inverter reconnects implying it disconnected, but disconnecting is not explicitly stated.
has_recoveryc13 drafted · lead Auto-reset (clears by itself)
Reconnects once values return to permissible range.
sec=11.1.20 h=1fc05755d2d4sec=h466 h=ceee8640eb7capplies_toc14 drafted · lead Sunny Boy 3.0-7.7-US-40 proposed
sec=h209 h=21872bbd9f73sec=h210 h=dba4882bde4c