Fault codes › Yaskawa Solectria › Yaskawa Solectria XGI 1500-DCG
Yaskawa Solectria XGI-1500-DCG CRIT-7
- Code
CRIT-7
- Shown as
- Ground Fault
- Vendor severity
- Critical
- Page
- 55
- ID
fc:yaskawa-solectria-xgi-1500-dcg-crit7
- IRI
https://solarlattice.org/kb/fc/yaskawa-solectria-xgi-1500-dcg-crit7
- Status
- active
- Also known as
- CRIT-7, crit7, Yaskawa Solectria CRIT-7, Ground Fault
- Category
- Inverters
Class
fault drafted · lead
Production
not stated
Decoded
Reports ground fault alarm or trip; look at PV array; do: contact system installer.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E018, ABB / FIMER PVS-60-TL E018, ABB / FIMER TRIO-20.0-27.6-TL E018, ABB / FIMER UNO-DM-3.3-5.0-PLUS E018, ABB / FIMER UNO-DM-6.0-PLUS E018
- CPS
- CPS SCA50-100K-T PFault0040, CPS SCA50-100K-T Protect0200
- Enphase
- Enphase M215-M250 GFI Tripped
- Fronius
- Fronius Galvo 475, Fronius Primo 475, Fronius Symo 475
- Huawei
- Huawei SUN2000-100KTL-USH0 2031
- SMA
- SMA SB-US-40 3501, SMA SB-US-40 3601, SMA SB-US-40 3701, SMA SB-US-41 3501, SMA SB-US-41 3601, SMA SB-US-41 3701, SMA SBSE-US-50 3501, SMA SBSE-US-50 3601, SMA SBSE-US-50 3701, SMA PEAK3-US 3501, SMA PEAK3-US 3601, SMA PEAK3-US 3701, SMA CORE1-US 3501, SMA CORE1-US 3701, SMA STP-TL-US 3501, SMA STP-TL-US 3601, SMA STP-TL-US 3701, SMA STP-X-US 3501, SMA STP-X-US 3601, SMA STP-X-US 3701, SMA SC-CP-XT 3501, SMA SC-CP-XT 3502, SMA SC-CP-XT 3507, SMA SC-CP-XT 3512, SMA SC-CP-XT 3515, SMA SC-CP-XT 3601, SMA SC-CP-XT 6487
- Schneider Electric
- Schneider Electric CL125 033
- Solis
- Solis S6-EH2P PV ISO-PRO01, Solis S6-EH2P PV ISO-PRO02, Solis S6-EH3P30-60K PV ISO-PRO01, Solis S6-EH3P30-60K PV ISO-PRO02, Solis S6-EH3P75-150K PV ISO-PRO01, Solis S6-EH3P75-150K PV ISO-PRO02
- Sungrow
- Sungrow SG200HX 1600-1615, Sungrow SG200HX 1632-1655, Sungrow SG250HX 1600-1615, Sungrow SG250HX 1632-1655, Sungrow SG350HX 1600-1615, Sungrow SG350HX 1632-1655
- Yaskawa Solectria
- Yaskawa Solectria SGI-XTM DC GND Fault, Yaskawa Solectria SGI-XTM RCM Fault, Yaskawa Solectria XGI-1500-1MW CRIT-7, Yaskawa Solectria XGI-1500 CRIT-7
Same code in other families
Claims
defined_in
c1 drafted · lead
XGI 1500 250 DCG IOM DOCR-071081-DD
has_event_class
c2 drafted · lead
Fault (device stops or needs intervention)
from the table header
reports
c3 drafted · lead
Ground fault alarm or trip
affects
c4 drafted · lead
PV array
review note: support check: partial - The PV array disconnect, combiners and panels are mentioned, but the passages do not state that the fault affects the…
mitigated_by
c5 drafted · lead
Contact system installer
has_recovery
c6 drafted · lead
Service required
Qualified person must locate and repair the ground fault; equipment must not be touched.
applies_to
c7 drafted · lead
Solectria XGI 1500-DCG
Data