Enphase M215-M250 GFI Tripped

Code
GFI Tripped
Page
28
ID
fc:enphase-m215-m250-gfitripped
IRI
https://solarlattice.org/kb/fc/enphase-m215-m250-gfitripped
Status
active
Also known as
GFI Tripped, gfitripped, Enphase GFI Tripped
Category
Inverters
Class fault verified · fact
Production not stated
Clears after a manual reset verified · fact

Decoded

Reports ground fault alarm or trip.

What can be behind Ground fault alarm or trip

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E018, ABB / FIMER PVS-60-TL E018, ABB / FIMER TRIO-20.0-27.6-TL E018, ABB / FIMER UNO-DM-3.3-5.0-PLUS E018, ABB / FIMER UNO-DM-6.0-PLUS E018
CPS
CPS SCA50-100K-T PFault0040, CPS SCA50-100K-T Protect0200
Fronius
Fronius Galvo 475, Fronius Primo 475, Fronius Symo 475
Huawei
Huawei SUN2000-100KTL-USH0 2031
SMA
SMA SB-US-40 3501, SMA SB-US-40 3601, SMA SB-US-40 3701, SMA SB-US-41 3501, SMA SB-US-41 3601, SMA SB-US-41 3701, SMA SBSE-US-50 3501, SMA SBSE-US-50 3601, SMA SBSE-US-50 3701, SMA PEAK3-US 3501, SMA PEAK3-US 3601, SMA PEAK3-US 3701, SMA CORE1-US 3501, SMA CORE1-US 3701, SMA STP-TL-US 3501, SMA STP-TL-US 3601, SMA STP-TL-US 3701, SMA STP-X-US 3501, SMA STP-X-US 3601, SMA STP-X-US 3701, SMA SC-CP-XT 3501, SMA SC-CP-XT 3502, SMA SC-CP-XT 3507, SMA SC-CP-XT 3512, SMA SC-CP-XT 3515, SMA SC-CP-XT 3601, SMA SC-CP-XT 6487
Schneider Electric
Schneider Electric CL125 033
Solis
Solis S6-EH2P PV ISO-PRO01, Solis S6-EH2P PV ISO-PRO02, Solis S6-EH3P30-60K PV ISO-PRO01, Solis S6-EH3P30-60K PV ISO-PRO02, Solis S6-EH3P75-150K PV ISO-PRO01, Solis S6-EH3P75-150K PV ISO-PRO02
Sungrow
Sungrow SG200HX 1600-1615, Sungrow SG200HX 1632-1655, Sungrow SG250HX 1600-1615, Sungrow SG250HX 1632-1655, Sungrow SG350HX 1600-1615, Sungrow SG350HX 1632-1655
Yaskawa Solectria
Yaskawa Solectria SGI-XTM DC GND Fault, Yaskawa Solectria SGI-XTM RCM Fault, Yaskawa Solectria XGI-1500-1MW CRIT-7, Yaskawa Solectria XGI-1500 CRIT-7, Yaskawa Solectria XGI-1500-DCG CRIT-7

Claims

defined_in

c1 drafted · lead Enphase M250 Installation and Operation Manual 60Hz

c2 drafted · lead Enphase Envoy S installation and operation manual

reports

c3 verified · fact Ground fault alarm or trip

verified by: review-workflowverified on: 2026-10-23

has_event_class

c4 verified · fact Fault (device stops or needs intervention)

verified by: review-workflowverified on: 2026-10-23

has_recovery

c5 verified · fact Manual reset (operator restarts or acknowledges)

Clear message sent via Envoy resets GFI sensor; contact support if it does not clear

verified by: review-workflowverified on: 2026-10-23

applies_to

c6 drafted · lead Enphase M215 / M250 Microinverters

Data