Fault codes › Enphase › Enphase M215 / M250 Microinverters
Enphase M215-M250 GFI Tripped
- Code
GFI Tripped
- Page
- 28
- ID
fc:enphase-m215-m250-gfitripped
- IRI
https://solarlattice.org/kb/fc/enphase-m215-m250-gfitripped
- Status
- active
- Also known as
- GFI Tripped, gfitripped, Enphase GFI Tripped
- Category
- Inverters
Class
fault verified · fact
Production
not stated
Decoded
Reports ground fault alarm or trip.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E018, ABB / FIMER PVS-60-TL E018, ABB / FIMER TRIO-20.0-27.6-TL E018, ABB / FIMER UNO-DM-3.3-5.0-PLUS E018, ABB / FIMER UNO-DM-6.0-PLUS E018
- CPS
- CPS SCA50-100K-T PFault0040, CPS SCA50-100K-T Protect0200
- Fronius
- Fronius Galvo 475, Fronius Primo 475, Fronius Symo 475
- Huawei
- Huawei SUN2000-100KTL-USH0 2031
- SMA
- SMA SB-US-40 3501, SMA SB-US-40 3601, SMA SB-US-40 3701, SMA SB-US-41 3501, SMA SB-US-41 3601, SMA SB-US-41 3701, SMA SBSE-US-50 3501, SMA SBSE-US-50 3601, SMA SBSE-US-50 3701, SMA PEAK3-US 3501, SMA PEAK3-US 3601, SMA PEAK3-US 3701, SMA CORE1-US 3501, SMA CORE1-US 3701, SMA STP-TL-US 3501, SMA STP-TL-US 3601, SMA STP-TL-US 3701, SMA STP-X-US 3501, SMA STP-X-US 3601, SMA STP-X-US 3701, SMA SC-CP-XT 3501, SMA SC-CP-XT 3502, SMA SC-CP-XT 3507, SMA SC-CP-XT 3512, SMA SC-CP-XT 3515, SMA SC-CP-XT 3601, SMA SC-CP-XT 6487
- Schneider Electric
- Schneider Electric CL125 033
- Solis
- Solis S6-EH2P PV ISO-PRO01, Solis S6-EH2P PV ISO-PRO02, Solis S6-EH3P30-60K PV ISO-PRO01, Solis S6-EH3P30-60K PV ISO-PRO02, Solis S6-EH3P75-150K PV ISO-PRO01, Solis S6-EH3P75-150K PV ISO-PRO02
- Sungrow
- Sungrow SG200HX 1600-1615, Sungrow SG200HX 1632-1655, Sungrow SG250HX 1600-1615, Sungrow SG250HX 1632-1655, Sungrow SG350HX 1600-1615, Sungrow SG350HX 1632-1655
- Yaskawa Solectria
- Yaskawa Solectria SGI-XTM DC GND Fault, Yaskawa Solectria SGI-XTM RCM Fault, Yaskawa Solectria XGI-1500-1MW CRIT-7, Yaskawa Solectria XGI-1500 CRIT-7, Yaskawa Solectria XGI-1500-DCG CRIT-7
Claims
defined_in
c1 drafted · lead
Enphase M250 Installation and Operation Manual 60Hz
c2 drafted · lead
Enphase Envoy S installation and operation manual
reports
c3 verified · fact
Ground fault alarm or trip
verified by: review-workflowverified on: 2026-10-23
has_event_class
c4 verified · fact
Fault (device stops or needs intervention)
verified by: review-workflowverified on: 2026-10-23
has_recovery
c5 verified · fact
Manual reset (operator restarts or acknowledges)
Clear message sent via Envoy resets GFI sensor; contact support if it does not clear
verified by: review-workflowverified on: 2026-10-23
applies_to
c6 drafted · lead
Enphase M215 / M250 Microinverters
Data