Schneider Electric fault codes
Schneider Electric Conext CL125
| Code | Shown as | Class | Production | Clears | Reports | Page |
|---|---|---|---|---|---|---|
| 002 | stops | Grid overvoltage | 123 | |||
| 003 | Grid transient voltage exceeds the permissible range. | by itself | Grid voltage out of range | 123 | ||
| 004 | stops | Grid undervoltage | 123 | |||
| 005 | by itself | Grid undervoltage | 123 | |||
| 006 | stops | by itself | AC overcurrent | 123 | ||
| 007 | Transient AC over current | by itself | AC overcurrent | 124 | ||
| 008 | Grid overfrequency | 124 | ||||
| 009 | Grid underfrequency | 124 | ||||
| 010 | Islanding | Islanding detected | 124 | |||
| 011 | by itself | High DC injection | 124 | |||
| 012 | Residual current leakagedetected is high. | High leakage current | 125 | |||
| 013 | by itself | Grid voltage out of range | 125 | |||
| 014 | Average grid over-voltage (10 minutes) | fault | stops | by itself | Grid overvoltage | 125 |
| 015 | Grid impedance exceeds inverter's limit. | fault | by itself | High grid impedance | 125 | |
| 016 | AC output overload | fault | by itself | Inverter overload | 125 | |
| 017 | Grid voltage imbalance | fault | by itself | Phase imbalance | 125 | |
| 019 | High transient DC bus voltage | fault | by itself | DC bus overvoltage | 126 | |
| 020 | High DC bus voltage | fault | by itself | DC bus overvoltage | 126 | |
| 021 | PV input over current | DC overcurrent | 126 | |||
| 022 | Over current protection | fault | Inverter overcurrent | 126 | ||
| 023 | PV configuration mode has changed during normal operation. | fault | after a manual reset | Configuration error | 126 | |
| 024 | Voltage imbalance at neutral point | by itself | Neutral point voltage imbalance | 126 | ||
| 025 | Transient unbalance of voltage neutral point | by itself | Neutral point voltage imbalance | 126 | ||
| 026 | Bus voltage is fluctuating. | by itself | DC bus voltage fluctuation | 126 | ||
| 028 | PV reverse connection is detected. | Reverse polarity | 126 | |||
| 030 | Clamp capacitance over-voltage event is detected. | by itself | Clamp capacitor overvoltage | 126 | ||
| 031 | Clamp capacitance under-voltage event is detected. | by itself | Clamp capacitor undervoltage | 126 | ||
| 032 | Clamp capacitance imbalance event is detected. | by itself | Clamp capacitor voltage imbalance | 126 | ||
| 033 | Clamp capacitance pre-charge ground fault is detected | by itself | Ground fault alarm or trip | 126 | ||
| 036 | Module temperature is too high. | Inverter overtemperature | 127 | |||
| 037 | Internal ambient temperature is too high. | Inverter overtemperature | 127 | |||
| 038 | by itself | 127 | ||||
| 039 | Inverter insulation resistance event (ISO-flt) | stops | by itself | Low insulation resistance | 127 | |
| 040 | stops | by itself | AC overcurrent, DC overcurrent, DC overvoltage | 127 | ||
| 041 | Current leakage sampling channel event | stops | by itself | Internal device fault | 127 | |
| 042 | AC current imbalance | stops | by itself | Phase imbalance | 127 | |
| 043 | fault | stops | after a manual reset | Inverter undertemperature | 128 | |
| 044 | DC/AC inversion circuit event | by itself | Internal device fault | 128 | ||
| 047 | fault | Configuration error | 128 | |||
| 048 | Phase-Rcurrent samplingchannel event | by itself | Internal device fault | 128 | ||
| 049 | Phase-S current sampling channel event | by itself | Internal device fault | 128 | ||
| 050 | Phase-T current sampling channel event | by itself | Internal device fault | 128 | ||
| 051 | Hardware over voltage or over current protection | Internal overcurrent or overvoltage | 27 | |||
| 053 | Grid voltage redundancy event is detected. | Grid voltage out of range | 128 | |||
| 054 | Grid frequency redundancy event is detected. | Grid frequency out of range | 129 | |||
| 055 | Inverter insulation resistance redundancy event is detected. | by itself | Low insulation resistance | 129 | ||
| 056 | Inverter leakage current redundancy event is detected. | High leakage current | 129 | |||
| 059 | Main DSP communication redundancy event is detected. | by itself | Internal communication failure | 129 | ||
| 060 | Main DSP data comparison event is detected. | by itself | Internal device fault | 129 | ||
| 070 | Fan event | fault | needs service | Fan fault alarm | 129 | |
| 071 | AC side SPD event | Surge protector alarm | 129 | |||
| 072 | DC side SPD event | needs service | Surge protector alarm | 129 | ||
| 074 | Communication event | warning | unaffected | Internal communication failure | 130 | |
| 075 | Solar irradiation is not sufficient for inverter operation | stops | by itself | Insufficient solar irradiance | 130 | |
| 076 | PV overload condition | PV input overload | 130 | |||
| 078 | PV power event warning | warning | Loose cable connection | 130 |