Solar Lattice

Fault codes › Schneider Electric › Schneider Electric Conext CL125

Schneider Electric CL125 032

Code
032
Shown as
Clamp capacitance imbalance event is detected.
Page
126
ID
fc:schneider-electric-conext-cl125-32
IRI
https://solarlattice.org/kb/fc/schneider-electric-conext-cl125-32
Status
active
Also known as
032, 32, Schneider Electric 032, Clamp capacitance imbalance event is detected.
Category
Inverters
Class not stated
Production not stated
Clears by itself verified · fact

Decoded

Reports clamp capacitor voltage imbalance.

What can be behind Clamp capacitor voltage imbalance

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Claims

defined_in

c1 drafted · lead Conext CL125 Owners Guide 975-0793 RevA

c2 drafted · lead Conext CL125 Modbus App Note

reports

c3 verified · fact Clamp capacitor voltage imbalance

verified by: review-workflowverified on: 2026-10-23

has_recovery

c4 verified · fact Auto-reset (clears by itself)

Contact technical support if the event persists.

verified by: review-workflowverified on: 2026-10-23review note: support check: partial - Auto recovery stated, but contact-support note is absent.

applies_to

c5 drafted · lead Schneider Electric Conext CL125

Data