High DC injection
High DC injection means the inverter's own monitoring has found too much DC current on its AC output. The manufacturer links it to transient conditions where impedance and voltage are unbalanced between the grid phases. First, raise the DCImax limit so the inverter has more room to adjust during transients. If the fault still does not clear after that, replace the inverter. Do not confuse it with Protect0180, a separate alarm for a DCI sampling offset. That one calls for recalibration if the inverter can start, and replacement if it keeps alarming and cannot start. Other inverter datasheets specify DC current injection as a small fraction of rated output current. Check the limit that applies to the unit you are working on.
<!-- review notes
- sentence 1: support check: partial - The passage lists monitoring of DC injection from AC output as a protection function, but doesn't state that high DC injection means the monitoring found too much DC current. -->
Referenced by
- DC injection
related_toc4 - ABB / FIMER PVS-166-175-TL E023
reportsc3 - ABB / FIMER PVS-60-TL E023
reportsc3 - ABB / FIMER TRIO-20.0-27.6-TL E023
reportsc3 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E023
reportsc4 - ABB / FIMER UNO-DM-6.0-PLUS E023
reportsc4 - Canadian Solar 185-255K DCinj-FAULT
reportsc2 - CPS SCA25KTL-208 Protect0170
reportsc3 - CPS SCA25KTL-480 Protect0170
reportsc3 - CPS SCA36KTL Protect0170
reportsc3 - CPS SCA50-100K-T Protect0170
reportsc3 - CPS SCA50-60KTL Protect0170
reportsc3 - CPS SCH100-125KTL Protect0170
reportsc3 - CPS SCH125KTL-AIO Protect0170
reportsc3 - CPS SCH200-250K-T Protect0170
reportsc3 - CPS SCH275KTL Protect0170
reportsc3 - CPS SCH350KTL Protect0170
reportsc3 - Fronius Galvo 408
reportsc2 - Fronius Primo 408
reportsc2 - Fronius Symo 408
reportsc2 - Huawei SUN2000-100KTL-USH0 2040
reportsc3 - Huawei SUN2000-25-30KTL-US 202
reportsc4 - Huawei SUN2000-45KTL-US-HV-D0 202
reportsc4 - KACO new energy blueplanet TL3 33
reportsc2 - Schneider Electric CL125 011
reportsc3 - SMA SB-US-40 601
reportsc2 - SMA SB-US-41 601
reportsc2 - SMA SBSE-US-50 601
reportsc2 - SMA PEAK3-US 601
reportsc2 - SMA CORE1-US 601
reportsc4 - SMA STP-TL-US 601
reportsc2 - SMA STP-X-US 601
reportsc2 - Solis 3P-5G-US DCInj-Fault
reportsc2 - Solis RHI-1P-HV DCInj-Fault
reportsc2 - Solis S6-EH1P DCInj-Fault
reportsc2 - Solis S6-EH2P DCInj-Fault
reportsc2 - Solis S6-EH3P30-60K DCInj-Fault
reportsc3 - Solis S6-EH3P75-150K DCInj-Fault
reportsc2 - Solis S6-GC DCInj-Fault
reportsc2 - Solis S6-GU DCInj-Fault
reportsc2 - Yaskawa Solectria PVI-25TL-R Protect0170
reportsc3