c1 drafted · lead Canadian Solar
- CSI Installation Manual 75-100K T480GL02-U USA V1.1 20211116
sec=1.1h=077e0ca26335
The CSI-75/80/90/100K-T480GL02-U is a family of Canadian Solar three-phase string inverters that turn PV array DC power into AC power for local loads and for export to the grid. The 100K model takes up to 1000 V DC and connects to a 480 V three-phase grid with PE at 60 Hz. Each input is rated for 26 A. The 75K has eight inputs, the 80K has nine, and the 90K and 100K each have ten. The 75K and 80K models have a maximum efficiency of 98.7%, and the 90K and 100K models reach 99.0%. The 75K model is rated at 90.2 A AC output current. RS485 communication is standard. Wifi, GPRS, PLC and Ethernet are optional. The DC connectors are MC4. Each unit has a two-line LCD display, weighs 85 kg and is rated at 65 dB(A) or less of noise.
<!-- review notes
manufactured_byc1 drafted · lead Canadian Solar
sec=1.1 h=077e0ca26335instance_ofThree-phase inverter converting PV DC power to AC for local loads and grid feed-in
sec=1.1 h=077e0ca26335uses_protocolStandard communication connection on all four models
tbl=15.r34 h=42b811f7646etbl=13.r34 h=4b1c03e265actbl=12.r34 h=0e0493ed939ctbl=14.r34 h=b46bf1121b82verified by: review-workflowverified on: 2026-10-24
Optional communication connection
tbl=15.r34 h=42b811f7646etbl=13.r34 h=4b1c03e265actbl=12.r34 h=0e0493ed939ctbl=14.r34 h=b46bf1121b82c5 drafted · lead Cellular data
Optional GPRS communication connection
tbl=15.r34 h=42b811f7646etbl=13.r34 h=4b1c03e265actbl=12.r34 h=0e0493ed939ctbl=14.r34 h=b46bf1121b82c6 drafted · lead Power line communication
Optional PLC communication connection
tbl=15.r34 h=42b811f7646etbl=13.r34 h=4b1c03e265actbl=12.r34 h=0e0493ed939ctbl=14.r34 h=b46bf1121b82Optional communication connection
tbl=15.r34 h=42b811f7646etbl=13.r34 h=4b1c03e265actbl=12.r34 h=0e0493ed939ctbl=14.r34 h=b46bf1121b82implementsc8 drafted · lead Maximum power point tracking
MPPT efficiency of 99.5% listed for the 100K model
tbl=15.r19 h=65cd7bb9927creview note: support check: partial - Only a 99.5% MPPT efficiency for the 100K is given; this implies MPPT but the other models are not covered.
compatible_withc9 drafted · lead Staubli MC4 PV connectors proposed
Datasheet lists MC4 as the DC connection type
tbl=13.r31 h=eb72f6e9bef7tbl=15.r31 h=7fea29909f04tbl=14.r31 h=23169d0c2dfdtbl=12.r31 h=b0bc6fce78e2review note: support check: partial - Datasheet lists MC4 connection, but the passages never name Staubli.
max_input_voltageConditions: Maximum DC input voltage, CSI-100K-T480GL02-U
tbl=15.r1 h=57f4ad580a7amax_input_currentc11 drafted · lead nominal 26 A
Conditions: Per input, 8 inputs (listed as 8*26), CSI-75K-T480GL02-U
tbl=12.r6 h=42254dd23cbcc12 verified · fact nominal 26 A
Conditions: Per input, 9 inputs (listed as 9*26), CSI-80K-T480GL02-U
tbl=13.r6 h=5202fb3a9c78verified by: review-workflowverified on: 2026-10-24
c13 drafted · lead nominal 26 A
Conditions: Per input, 10 inputs (listed as 10*26), CSI-90K-T480GL02-U and CSI-100K-T480GL02-U
tbl=14.r6 h=0c4d7ff7ed07tbl=15.r6 h=3c127d353bd9rated_output_currentc14 drafted · lead nominal 90.2 A
Conditions: Rated output current, CSI-75K-T480GL02-U
tbl=12.r13 h=b93507e9bd8fnominal_voltagec15 drafted · lead nominal 480 V
Conditions: Rated grid voltage, three-phase plus PE (3/PE~480), CSI-100K-T480GL02-U
tbl=15.r12 h=d032023f4d7efrequencyc16 drafted · lead nominal 60 HZ
Conditions: Rated grid frequency, CSI-100K-T480GL02-U
tbl=15.r16 h=eb1c013b080defficiencyc17 drafted · lead nominal 99 PERCENT
Conditions: Maximum efficiency, CSI-90K-T480GL02-U and CSI-100K-T480GL02-U
tbl=15.r17 h=a5250f05d529tbl=14.r17 h=febf405dd0d1review note: possible conflict with c18 (same source; check the conditions); possible conflict with c19 (same source; check the conditions); possible conflict with c20 (same source; check the conditions)
c18 verified · fact nominal 98.7 PERCENT
Conditions: Maximum efficiency, CSI-75K-T480GL02-U and CSI-80K-T480GL02-U
tbl=12.r17 h=64e29dee45fatbl=13.r17 h=bee2d7422533verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c17 (same source; check the conditions); possible conflict with c19 (same source; check the conditions); possible conflict with c20 (same source; check the conditions)
c19 verified · fact nominal 98.5 PERCENT
Conditions: EU (European weighted) efficiency, CSI-100K-T480GL02-U
tbl=15.r18 h=754268a04d85verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c17 (same source; check the conditions); possible conflict with c18 (same source; check the conditions); possible conflict with c20 (same source; check the conditions)
c20 drafted · lead nominal 98.3 PERCENT
Conditions: EU (European weighted) efficiency, CSI-75K-T480GL02-U and CSI-80K-T480GL02-U
tbl=13.r18 h=342938652fe1tbl=12.r18 h=25e1cc297bdbreview note: possible conflict with c17 (same source; check the conditions); possible conflict with c18 (same source; check the conditions); possible conflict with c19 (same source; check the conditions)
applies_to c11applies_to c7applies_to c8applies_to c7applies_to c8applies_to c7applies_to c6applies_to c6applies_to c9applies_to c9applies_to c7applies_to c6applies_to c7