c1 drafted · lead Canadian Solar
- CSI Installation Manual CSI-125KTL-GS-E USA V1.3
sec=1.1h=10ac41ff3a63
The CSI-125KTL-GS-E is a Canadian Solar three-phase grid-tied inverter. It converts DC power from a PV array into AC power for local loads and for export to the grid. It uses a transformerless design with fan cooling. The enclosure is rated NEMA 4X/IP65 and the display is an LCD. On the DC side it takes up to 1500 V and up to 150 A. It has one MPPT that accepts up to 20 strings through MC4 connectors. On the AC side it connects to a 600 V three-phase grid at 60 Hz and delivers a rated output current of 120 A. The datasheet gives a maximum efficiency of 99.1 percent, an EU efficiency of 98.6 percent and an operating ambient range of -25 to 60 degrees C. It communicates over RS485 or Ethernet and supports over-the-air firmware updates. It is listed to UL 1741, UL 1741 SA, Rule 21, UL 1998, UL 1699B, IEEE 1547, FCC Part 15 and CSA C22.2 107.1. If the OV-BUS alarm appears, the inverter has seen excessive voltage on its internal DC bus. Measure the DC and AC voltages and compare them with the LCD readings. Internal damage or a wire that came loose in shipping may mean the inverter must be replaced.
<!-- review notes
manufactured_byc1 drafted · lead Canadian Solar
sec=1.1 h=10ac41ff3a63instance_ofThree-phase grid-tied PV inverter, transformerless topology
sec=1.1 h=10ac41ff3a63review note: support check: partial - Passage shows it's a three-phase inverter converting DC to AC feeding the grid, but transformerless topology isn't in this passage.
uses_protocoltbl=12.r33 h=54f7eea77dc2tbl=12.r33 h=54f7eea77dc2implementsc5 drafted · lead Remote firmware update
Datasheet lists OTA update as supported
tbl=12.r34 h=a5b64fbb8583c6 drafted · lead Maximum power point tracking
Single MPPT
tbl=12.r7 h=176ad44815a4tbl=12.r18 h=3c9c8677fb3dcertified_toc7 drafted · lead UL 1741 proposed
tbl=12.r29 h=83e27d6aa879c8 drafted · lead UL 1741 SA proposed
tbl=12.r29 h=83e27d6aa879c9 drafted · lead CA Rule 21 proposed
Listed including Rule 21 Phase II and III
tbl=12.r29 h=83e27d6aa879c10 drafted · lead UL 1998 proposed
tbl=12.r29 h=83e27d6aa879c11 verified · fact UL 1699B proposed
tbl=12.r29 h=83e27d6aa879verified by: review-workflowverified on: 2026-10-24
c12 verified · fact IEEE 1547 proposed
tbl=12.r29 h=83e27d6aa879verified by: review-workflowverified on: 2026-10-24
c13 drafted · lead FCC Part 15 proposed
Class A and B
tbl=12.r29 h=83e27d6aa879c14 drafted · lead CSA C22.2 No. 107.1 proposed
tbl=12.r29 h=83e27d6aa879max_input_voltageConditions: Maximum DC input voltage
tbl=12.r1 h=9319b4374a90max_input_currentConditions: Maximum DC input current, inverter has a single MPPT
tbl=12.r5 h=7be2e2c95c23tbl=12.r7 h=176ad44815a4rated_output_currentc17 drafted · lead nominal 120 A
Conditions: Rated AC output current
tbl=12.r12 h=0ea241078b86nominal_voltagec18 drafted · lead nominal 600 V
Conditions: Rated grid voltage, three-phase plus PE
tbl=12.r11 h=44ddabd44010frequencyc19 drafted · lead nominal 60 HZ
Conditions: Rated grid frequency
tbl=12.r15 h=e1b1d3f4f34eefficiencyc20 drafted · lead nominal 99.1 PERCENT
Conditions: Maximum (peak) efficiency
tbl=12.r16 h=a9561566ff16review note: possible conflict with c21 (same source; check the conditions)
c21 drafted · lead nominal 98.6 PERCENT
Conditions: EU (European weighted) efficiency
tbl=12.r17 h=5ced0dbce29freview note: possible conflict with c20 (same source; check the conditions)
operating_temperaturec22 verified · fact -25–60 DEG_C
Conditions: Operating ambient temperature range
tbl=12.r23 h=006e7600084bverified by: review-workflowverified on: 2026-10-24
max_countConditions: Maximum number of input strings on the single MPPT
tbl=12.r7 h=176ad44815a4applies_to c7applies_to c2applies_to c7applies_to c7applies_to c8applies_to c7applies_to c6applies_to c6applies_to c2applies_to c6applies_to c7