Firmware update failure

ID
symptom:firmware-update-failure
IRI
https://solarlattice.org/kb/symptom/firmware-update-failure
Status
active

A failed firmware update shows up as an event message in the device's event log or on its user interface, not as a change in power output. On SMA string inverters, event 7330 (Condition test failed) means the update file did not pass the update-condition check because it is not the right package for that inverter. Events 7331 and 7332 show the update file being copied and then stored in the inverter's internal memory, so they tell you how far the update got before it stopped. On an Eaton surge protection device, the message that a codepack integrity check aborted the update means one of the images was corrupt, and the firmware should be installed again. After any update, open the user interface and look in the events for the success message (event 7320 on SMA units) to confirm the update finished. If the condition check fails, first make sure the update file you selected is the correct one for that product. Firmware problems can lead to a complete inverter failure, and software issues are normally fixed with a firmware update. If a restart does not help or the fault keeps coming back, a service team usually needs to find the cause.

<!-- review notes

Claims

observed_as

c1 drafted · lead Update condition test failed

SMA event 7330: the update conditions check did not pass because the firmware package does not suit this inverter model.

The testing of the update conditions was not successful. The firmware update package is not suitable for this inverter.

c2 drafted · lead Firmware integrity check abort

On the Eaton SPD, a codepack integrity check stops the update when any image in a multi-image update is corrupt. The required action is to re-install the firmware.

Referenced by

Data