c1 verified · fact Transfer relay
Event 9208: relay in the automatic transfer switching device is faulty.
- sbsxx-us-10-event-messages
sec=h1h=a056be6df42b
verified by: review-workflowverified on: 2026-10-24
This fault covers problems in the automatic transfer switch or backup module that moves loads to the battery-backup supply when the grid fails. Typical signs are event messages for a faulty relay, the bimetal switch, N-PE monitoring, overtemperature, or lost communication with the backup unit controller. In the field, the switch may not transfer when the grid fails, or it may click over while the backup loads still get no power. To confirm, simulate a grid failure by switching off the pre-meter fuse, wait for the set delay and listen for the transfer click. Check the transfer switch fuses and the B6 pre-fuse, make sure the backup type is set to automatic backup operation, and make sure the SPS IN and SPS OUT cables are not swapped. Check that the communication cable meets its requirements, then run a communication test; for backup overvoltage, check the backup port wiring and restart. If the relay or other hardware in the transfer switch is faulty, contact the manufacturer of the switching device.
affectsc1 verified · fact Transfer relay
Event 9208: relay in the automatic transfer switching device is faulty.
sec=h1 h=a056be6df42bverified by: review-workflowverified on: 2026-10-24
c2 drafted · lead Transfer switch controller
SMA Backup Unit Controller installed in the automatic transfer switch.
sec=h1 h=a056be6df42bcaused_byc3 drafted · lead Relay failure
sec=h1 h=a056be6df42bc4 drafted · lead Installation error
SPS IN and SPS OUT cables miswired or swapped; installation of the transfer device to be checked on overtemperature.
sec=h1 h=a056be6df42btbl=1.r3 h=53638835c842tbl=18.r3 h=c7b40a34efa6sec=h1 h=5233ab3eb379c5 drafted · lead Inverter parameter settings
Backup type parameter not set to automatic backup operation, or switch-on delay not yet elapsed.
tbl=1.r3 h=53638835c842tbl=18.r3 h=c7b40a34efa6sec=h1 h=5233ab3eb379presents_asc6 drafted · lead Backup mode unavailable
tbl=1.r3 h=53638835c842tbl=18.r3 h=c7b40a34efa6sec=h1 h=5233ab3eb379c7 drafted · lead Transfer switch transfer failure
Device does not switch on grid failure, or switches but backup loads stay unpowered.
tbl=1.r3 h=53638835c842tbl=18.r3 h=c7b40a34efa6tbl=1.r2 h=09c03201685atbl=18.r2 h=863af509f134c8 drafted · lead Backup unit overtemperature
sec=h1 h=a056be6df42bc9 drafted · lead Communication loss
Communication between inverter and Backup Unit Controller disrupted.
sec=h1 h=a056be6df42bc10 drafted · lead Firmware update failure
Backup Unit Controller update failed.
sec=h1 h=a056be6df42bc11 drafted · lead Backup output AC overvoltage
tbl=10.r8 h=bcf28adc0525tbl=14.r8 h=bcf28adc0525tbl=27.r18 h=1f509fcb78detbl=19.r18 h=1f509fcb78detbl=26.r18 h=1f509fcb78dereview note: support check: partial - OV-Vbackup backup overvoltage messages exist, but they are inverter alarms and the passages do not tie them to the automatic backup unit fault.; review: partial - The Solis rows describe a backup overvoltage (OV-VBackup) alarm on the inverter's backup port, but none of them connect it to an automatic backup unit or transfer switch fault.
detected_byc12 drafted · lead Backup transition test
Simulate a grid failure by switching off the pre-meter fuse and listen for the transfer click.
sec=h85 h=d64eb21249a5c13 drafted · lead Communication test proposed
sec=h1 h=a056be6df42bmitigated_byc14 drafted · lead External fuse check
Check transfer device fuses; B6 pre-fuse and monitoring relay pre-fuse must be switched on.
tbl=18.r6 h=37782d83b92etbl=1.r6 h=ac7d628f14ebtbl=1.r3 h=53638835c842tbl=18.r3 h=c7b40a34efa6sec=h1 h=5233ab3eb379tbl=18.r5 h=c030ffda712ereview note: support check: partial - Checking transfer device fuses, the B6 pre-fuse and the monitoring relay pre-fuse appear, but the B6 passages describe backup continuing after grid return, not a cause of this fault.
c15 drafted · lead Communication cable check
sec=h1 h=a056be6df42bc16 drafted · lead Inverter settings review
tbl=1.r3 h=53638835c842tbl=18.r3 h=c7b40a34efa6sec=h1 h=5233ab3eb379c17 verified · fact Firmware update
Inverter firmware 3.12.15.R or later needed to set backup parameters.
tbl=1.r3 h=53638835c842tbl=18.r3 h=c7b40a34efa6sec=h1 h=5233ab3eb379verified by: review-workflowverified on: 2026-10-24
c18 drafted · lead Wiring and terminal check
tbl=27.r18 h=1f509fcb78detbl=1.r3 h=53638835c842tbl=19.r18 h=1f509fcb78detbl=26.r18 h=1f509fcb78dec19 drafted · lead Backup load reduction
sec=h1 h=a056be6df42btbl=29.r15 h=3c5c09781487tbl=28.r16 h=3c5c09781487review note: support check: partial - Reducing backup loads appears for backup short circuit and LLC overcurrent, not directly for the automatic transfer switch fault.
c20 drafted · lead Inverter restart
tbl=10.r8 h=bcf28adc0525tbl=14.r8 h=bcf28adc0525tbl=27.r18 h=1f509fcb78dereview note: support check: partial - Restarting the inverter appears only for the OV-Vbackup alarm, not as a general mitigation for the transfer unit fault.
c21 verified · fact Contact manufacturer service
Contact the manufacturer of the automatic transfer switching device for relay, bimetal switch or N-PE monitoring errors.
sec=h1 h=a056be6df42bverified by: review-workflowverified on: 2026-10-24