Backup unit overtemperature

ID
symptom:backup-unit-overtemperature
IRI
https://solarlattice.org/kb/symptom/backup-unit-overtemperature
Status
active
Also known as
Backup module bimetal switch, backup module overtemperature state, bimetal switch tripped, Backup module overtemperature, overtemperature state

This symptom is reported by the battery inverter when the backup module (backup box) inside the automatic transfer switching device gets too hot or its bimetal switch trips. On Sunny Boy Storage units it appears in the event log as event 9207 for the bimetal switch or event 9211 for backup module overtemperature. The bimetal switch normally opens because of high temperature, but the trip is not always caused by the box or ambient temperature, so it can also point to a fault in the transfer switching device itself. The backup box is approved for use between -25°C and 60°C, so first check that the site temperature stays within that range. For an overtemperature message, check how the backup module is installed. For a bimetal switch message, check the bimetal switch itself. An external heat source can overheat the transfer switching device so that its lid locks. Remove the heat source and let the unit cool back into its allowed range. If the message is still there after these checks, contact the manufacturer of the automatic transfer switching device, because the fault is treated as a fault of that unit.

<!-- review notes

Claims

observed_as

c1 verified · fact Inverter fault code display

On Sunny Boy Storage SBSx.x-US-10 battery inverters this shows as event 9207 (backup module bimetal switch tripped) or event 9211 (backup module overtemperature). Both point to the automatic transfer switching device.

verified by: review-workflowverified on: 2026-10-24