- Sunny Tripower STPXX-50 communication interrupt with ennexOS portal after firmware update
sec=h1h=9baa54672267 - fronius-symo-ul-emanual-status-codes
tbl=15.r14h=62a188b75c86
Device firmware defect
A firmware defect is a fault in the device software that makes an inverter behave wrongly even when its hardware is fine. It can show up as communication to the monitoring portal dropping after a firmware update and not coming back by itself, which may also trigger configured fall-back modes. Other signs include false trips of fault codes or of the arc fault detector, a software-problem code with no grid feed-in, and firmware versions that do not match between devices or clusters. Check the event log and the installed firmware version to confirm. For Modbus TCP loss, switch the Modbus TCP server parameter off and on to see whether the issue is software-side before you check the cabling. The usual fix is an AC reset and then updating to the firmware version that corrects the bug. If the update file is defective, repeat the update. Never cut DC or AC power or pull the USB stick during an update, because that can damage the software or the device. An internal communication error shown during a firmware update is normal and is not a fault.
<!-- review notes
- sentence 1: support check: partial - u38 and u35 show software problems and bugfixes that cause wrong behavior, but nothing says the hardware is fine or defines a firmware defect.
- sentence 4: support check: partial - u9 and u22 support checking event logs and firmware version and toggling the Modbus TCP server before checking cabling, but the passages do not say that toggling shows whether the issue is software-side.
- sentence 5: support check: partial - u38 gives an AC reset followed by a firmware update, and u4 says to repeat the update for a defective file, but calling this the usual fix for every firmware defect goes beyond the passages.
- sentence 1: review: partial - The passages show software problems and firmware bugs causing false trips and no feed-in, but nothing says the hardware is fine or defines a firmware defect.
- sentence 4: review: partial - The SMA article supports collecting event logs and the firmware version, and toggling Modbus TCP Server On before checking cabling, but it says the toggle tests whether the problem is only with Modbus TCP communications, not whether it is software-side. -->
Claims
affects
presents_as
c2 drafted · lead Communication loss
In rare cases, after a firmware update the link between an STPxx-50 inverter and the ennexOS portal drops and does not restart by itself.
c3 verified · fact Fallback operation after loss of control or meter signal
The communication loss caused by the firmware issue can trigger fall-back modes, if they are configured.
- Sunny Tripower STPXX-50 communication interrupt with ennexOS portal after firmware update
sec=h1h=9baa54672267
verified by: review-workflowverified on: 2026-10-24
c4 drafted · lead Spurious fault event
Firmware changelog bugfixes cover false trips of several state codes and false Arc Guard triggering.
- Fronius SnapINverter Galvo Symo Primo Firmware Changelog
sec=h213h=422048a9970a
c6 drafted · lead Software version mismatch
Extension clusters can run different firmware from the main cluster, or internal devices can carry incompatible firmware versions.
- 278742
tbl=75.r5h=f5de6b7cabf9 - 259761
tbl=71.r5h=acfa537571e5 - FIMER PVM-75-155-TL-US User Product Manual RevA
sec=h268h=4fa3b4c5c1c3
c7 drafted · lead Firmware update failure
Programming firmware from an SD card can fail, and the update file can be defective or damaged.
- FIMER PVS-60-TL-US Product Manual RevB
sec=h173h=d427985877e8 - 259761
tbl=65.r5h=daed1a94a969 - SI30M-44M-60H-80H-BE-en-33W
tbl=44h=1f5b39a30613
leads_to
c5 drafted · lead Arc fault nuisance trip
A firmware release reduced false triggering of the Arc Guard.
- Fronius SnapINverter Galvo Symo Primo Firmware Changelog
sec=h213h=422048a9970a
caused_by
c8 drafted · lead Power supply interruption proposed
Cutting the DC or AC supply, or pulling the USB stick, during an update can damage the software or the device.
- KACO blueplanet 87.0-165 TL3 Operating Manual EN 2020-10 (Siemens-hosted copy)
sec=h243h=27ad31779984
review note: support check: partial - u18 says an interrupted power supply can damage the software or device and that the USB stick should not be removed, but it frames this as an update failure and not a firmware defect, and the passages do not list AC or DC cut or USB removal as a cause of a firmware defect.
mitigated_by
c9 verified · fact Firmware update
For example, version 2.2.12.R or higher fixes the STPxx-50 portal communication issue.
- Sunny Tripower STPXX-50 communication interrupt with ennexOS portal after firmware update
sec=h1h=9baa54672267 - fronius-symo-ul-emanual-status-codes
tbl=15.r14h=62a188b75c86 - 278742
tbl=75.r5h=f5de6b7cabf9 - 259761
tbl=71.r5h=acfa537571e5
verified by: review-workflowverified on: 2026-10-24
c10 drafted · lead Update retry
If the update file is defective, repeat the firmware update.
- 259761
tbl=65.r5h=daed1a94a969
review note: review: partial - The row supports repeating the update when the update file is defective, but a defective update file is a failed update, not clearly a defect in the device firmware, so the mitigation link to this failure mode is only loosely…
c11 drafted · lead Inverter restart
For a software problem code, an AC reset (switching the circuit breaker off and on) is the first remedy.
- fronius-symo-ul-emanual-status-codes
tbl=15.r14h=62a188b75c86
detected_by
c12 drafted · lead Inverter event and data log export
Check the event logs and the installed firmware version to confirm whether an update finished and how communication behaved.
- Communication Problem to 3rd Party Monitoring (Modbus TCP)
sec=h1h=234a5b21f1c1 - SHPxxx-US-21-BE-en-11
sec=h260h=dea7e0f7a51b
review note: support check: partial - u9 asks for the inverter event logs and the installed firmware version, and u22 says to check the events to see whether a firmware update completed, but the passages do not frame this as detecting a firmware defect, and u9 does not tie it to confirming an update.
distinguished_from
c13 drafted · lead Monitoring network configuration fault — told apart by Communication test proposed
Switch the Modbus TCP server parameter off and back on. If communication returns, the problem is limited to Modbus TCP. If it stays down, check the network cabling and RJ45 connections.
- Communication Problem to 3rd Party Monitoring (Modbus TCP)
sec=h1h=234a5b21f1c1
review note: support check: partial - u9 describes toggling the Modbus TCP Server parameter to check whether the problem is limited to Modbus TCP and mentions checking network cabling, but it does not compare this with a firmware defect or say that persistent loss means checking the RJ45 connections.
Referenced by
- Battery thermal management failure
caused_byc2 - Inverter-BMS communication fault
caused_byc6 - Monitoring network configuration fault
caused_byc4