Solar Lattice

Symptom

Grid synchronization failure

ID
symptom:grid-sync-failure
IRI
https://solarlattice.org/kb/symptom/grid-sync-failure
Status
active
Also known as
Grid failure, Grid Abnormal, Grid Uncompliant, Grid incident

The inverter does not connect to the utility grid, or drops off it, and shows a message such as waiting for grid voltage, grid failure, grid abnormal or grid incident. In monitoring data, AC output stays at zero even though production conditions are good, often because the inverter did not restart after a grid fault; the display or the data log shows the fault code. If the grid itself is the cause, the measured voltage or frequency is outside the trip limits, a zero-sequence overvoltage is present, or the frequency changes very sharply. Usually the inverter reconnects by itself once the grid is back to normal; if the fault keeps coming back, measure the actual grid and contact the utility if its values are outside the set range. Check on site first: is the AC circuit breaker closed, is the AC cable firmly connected to the correct terminals, and does the grid supply power reliably. If the grid is within limits and the wiring is sound, suspect the configuration: a wrong country data set can also prevent connection. If a restart does not clear the fault, or the fault keeps recurring, a service team usually has to find the cause; software issues may be fixed by a firmware update.

<!-- review notes

Claims

observed_as

c1 drafted · lead Zero AC grid voltage

The inverter reports that it is waiting for grid voltage, or reports a grid power outage. Causes named in the sources: the AC breaker is open, the AC cable is miswired or loose, or the grid itself is out.

review note: support check: partial - Waiting for grid voltage, grid power outage, breaker and cable causes are stated, but zero AC voltage as a measurement is not explicit and the passages don't say the AC breaker is open.

c2 drafted · lead Grid voltage outside limits

Over- or undervoltage measured beyond the protection trip thresholds blocks connection.

c3 verified · fact Grid frequency outside limits

Over- or underfrequency, or a very large change in frequency, causes a disconnect.

verified by: review-workflowverified on: 2026-10-20

c4 verified · fact Zero-sequence imbalance

The Grid Uncompliant point includes zero-sequence overvoltage beyond the hardware trip thresholds.

verified by: review-workflowverified on: 2026-10-20

c5 drafted · lead Zero inverter AC output

The inverter does not restart after a grid fault, even though production conditions are good.

review note: support check: partial - Passages say the inverter not working despite good production conditions often reflects no restart after grid faults, but the specific zero-power and irradiance signal values are not stated.