Fault codes › Yaskawa Solectria › Solectria PVI 23/28/36TL
Yaskawa Solectria PVI-TL PV1 (2) VoltOver
- Code
PV1 (2) VoltOver
- Shown as
- DC input voltage exceeds the specified value
- Vendor severity
- Protection
- Page
- 54
- ID
fc:yaskawa-solectria-pvi-23-36tl-pv12voltover
- IRI
https://solarlattice.org/kb/fc/yaskawa-solectria-pvi-23-36tl-pv12voltover
- Status
- active
- Also known as
- PV1 (2) VoltOver, pv12voltover, Yaskawa Solectria PV1 (2) VoltOver, DC input voltage exceeds the specified value
- Category
- Inverters
Class
fault drafted · lead
Production
not stated
Decoded
Reports DC overvoltage; confirm with open-circuit voltage measurement; do: contact manufacturer service.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
- PVI 23-28TL — Yaskawa Solectria Solar · page 54 drafted · lead
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E002, ABB / FIMER PVS-166-175-TL E057, ABB / FIMER PVS-60-TL CODE:06, ABB / FIMER PVS-60-TL E002, ABB / FIMER PVS-60-TL E057, ABB / FIMER TRIO-20.0-27.6-TL CODE:06, ABB / FIMER TRIO-20.0-27.6-TL E002, ABB / FIMER TRIO-20.0-27.6-TL E057, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:06, ABB / FIMER UNO-DM-3.3-5.0-PLUS E002, ABB / FIMER UNO-DM-3.3-5.0-PLUS E057, ABB / FIMER UNO-DM-6.0-PLUS CODE:06, ABB / FIMER UNO-DM-6.0-PLUS E002, ABB / FIMER UNO-DM-6.0-PLUS E057
- CPS
- CPS SCA25KTL-208 PV2VoltOver, CPS SCA25KTL-480 PVVoltOver, CPS SCA36KTL PV2VoltOver, CPS SCA50-100K-T Fault4040, CPS SCA50-100K-T Protect0370, CPS SCA50-100K-T Protect0420, CPS SCA50-100K-T Protect0440, CPS SCA50-100K-T Protect0800, CPS SCA50-100K-T Protect0830, CPS SCA50-100K-T Protect0860, CPS SCA50-60KTL PV2VoltOver, CPS SCH100-125KTL PVVoltOver, CPS SCH125KTL-AIO PVVoltOver, CPS SCH275KTL PVVoltOver, CPS SCH350KTL PVVoltOver
- Canadian Solar
- Canadian Solar 125K-T600GL02 OV-DC, Canadian Solar 125KTL-GS-E OV-DC, Canadian Solar 185-255K OV-DC01/02/03/04, Canadian Solar 23-28KTL-CT PVVoltOver, Canadian Solar 25-40K-T480GL01 OV-DC, Canadian Solar 25-40KTL-GS-FL OV-DC, Canadian Solar 50-66K-T480GL01 OV-DC, Canadian Solar 50-66KTL-GS-FL OV-DC, Canadian Solar 75-100K-T480GL02 OV-DC
- Fronius
- Fronius Galvo 309, Fronius Symo 309, Fronius Symo 313
- Huawei
- Huawei SUN2000-100KTL-USH0 2001, Huawei SUN2000-25-30KTL-US 103, Huawei SUN2000-45KTL-US-HV-D0 103
- KACO new energy
- KACO new energy blueplanet TL3 118, KACO new energy blueplanet TL3 119, KACO new energy blueplanet TL3 38, KACO new energy blueplanet TL3 60
- SMA
- SMA SB-US-40 3401-3407, SMA SB-US-41 3401, SMA SB-US-41 3402, SMA SB-US-41 3407, SMA SBSE-US-50 3401, SMA SBSE-US-50 3402, SMA SBSE-US-50 3407, SMA SBSE-US-50 3410, SMA SBSE-US-50 3411, SMA CORE1-US 3401, SMA CORE1-US 3402, SMA CORE1-US 3404, SMA CORE1-US 3407, SMA CORE1-US 3410, SMA CORE1-US 3411, SMA CORE1-US 3412, SMA STP-TL-US 3401-3402, SMA SC-CP-XT 3403, SMA SC-CP-XT 3404, SMA SC-CP-XT 3406, SMA SI-US W853, SMA SI-US W863, SMA SI-US W873, SMA SI-US W883
- Schneider Electric
- Schneider Electric CL125 040
- Solis
- Solis 1P-4G-US OV-DC, Solis 3P-5G-US OV-DC01/02/03/04, Solis RHI-1P-HV OV-DC01/02/03/04, Solis S5-GC OV-DC, Solis S6-EH1P OV-DC01/02/03/04, Solis S6-EH2P OV-DC01, Solis S6-EH2P OV-DC02, Solis S6-EH3P30-60K OV-DC01, Solis S6-EH3P30-60K OV-DC02, Solis S6-EH3P75-150K OV-DC01, Solis S6-EH3P75-150K OV-DC02, Solis S6-GC OV-DC, Solis S6-GU OV-DC
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL PV1 (2) VoltOver, Yaskawa Solectria PVI-25TL-R PVVoltOver, Yaskawa Solectria SGI-XTM DC Volt High
Same code in other families
Claims
defined_in
c1 drafted · lead
PVI 23-28TL
has_event_class
c2 drafted · lead
Fault (device stops or needs intervention)
from the Type column
reports
c3 drafted · lead
DC overvoltage
detected_by
c4 drafted · lead
Open-circuit voltage measurement
review note: support check: partial - Passages say verify DC open circuit voltage is within range, but not that detection is by Voc measurement.
mitigated_by
c5 drafted · lead
Contact manufacturer service
Final escalation if the alarm persists after restart.
has_recovery
c6 drafted · lead
Auto-reset (clears by itself)
Watch for automatic clearing first; then verify Voc, power cycle; then service.
applies_to
c7 drafted · lead
Solectria PVI 23-36TL
Data