Canadian Solar 50-66K-T480GL01 OV-DC

Code
OV-DC
Shown as
DC voltage is too high
Page
38
ID
fc:canadian-solar-50-66k-t480gl01-ovdc
IRI
https://solarlattice.org/kb/fc/canadian-solar-50-66k-t480gl01-ovdc
Status
active
Also known as
OV-DC, ovdc, Canadian Solar OV-DC, DC voltage is too high
Category
Inverters
Class not stated
Production not stated
Clears not stated

Decoded

Reports DC overvoltage; look at PV array; confirm with DC voltage measurement; do: string configuration correction, inverter replacement.

What can be behind DC overvoltage

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E002, ABB / FIMER PVS-166-175-TL E057, ABB / FIMER PVS-60-TL CODE:06, ABB / FIMER PVS-60-TL E002, ABB / FIMER PVS-60-TL E057, ABB / FIMER TRIO-20.0-27.6-TL CODE:06, ABB / FIMER TRIO-20.0-27.6-TL E002, ABB / FIMER TRIO-20.0-27.6-TL E057, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:06, ABB / FIMER UNO-DM-3.3-5.0-PLUS E002, ABB / FIMER UNO-DM-3.3-5.0-PLUS E057, ABB / FIMER UNO-DM-6.0-PLUS CODE:06, ABB / FIMER UNO-DM-6.0-PLUS E002, ABB / FIMER UNO-DM-6.0-PLUS E057
CPS
CPS SCA25KTL-208 PV2VoltOver, CPS SCA25KTL-480 PVVoltOver, CPS SCA36KTL PV2VoltOver, CPS SCA50-100K-T Fault4040, CPS SCA50-100K-T Protect0370, CPS SCA50-100K-T Protect0420, CPS SCA50-100K-T Protect0440, CPS SCA50-100K-T Protect0800, CPS SCA50-100K-T Protect0830, CPS SCA50-100K-T Protect0860, CPS SCA50-60KTL PV2VoltOver, CPS SCH100-125KTL PVVoltOver, CPS SCH125KTL-AIO PVVoltOver, CPS SCH275KTL PVVoltOver, CPS SCH350KTL PVVoltOver
Canadian Solar
Canadian Solar 125K-T600GL02 OV-DC, Canadian Solar 125KTL-GS-E OV-DC, Canadian Solar 185-255K OV-DC01/02/03/04, Canadian Solar 23-28KTL-CT PVVoltOver, Canadian Solar 25-40K-T480GL01 OV-DC, Canadian Solar 25-40KTL-GS-FL OV-DC, Canadian Solar 50-66KTL-GS-FL OV-DC, Canadian Solar 75-100K-T480GL02 OV-DC
Fronius
Fronius Galvo 309, Fronius Symo 309, Fronius Symo 313
Huawei
Huawei SUN2000-100KTL-USH0 2001, Huawei SUN2000-25-30KTL-US 103, Huawei SUN2000-45KTL-US-HV-D0 103
KACO new energy
KACO new energy blueplanet TL3 118, KACO new energy blueplanet TL3 119, KACO new energy blueplanet TL3 38, KACO new energy blueplanet TL3 60
SMA
SMA SB-US-40 3401-3407, SMA SB-US-41 3401, SMA SB-US-41 3402, SMA SB-US-41 3407, SMA SBSE-US-50 3401, SMA SBSE-US-50 3402, SMA SBSE-US-50 3407, SMA SBSE-US-50 3410, SMA SBSE-US-50 3411, SMA CORE1-US 3401, SMA CORE1-US 3402, SMA CORE1-US 3404, SMA CORE1-US 3407, SMA CORE1-US 3410, SMA CORE1-US 3411, SMA CORE1-US 3412, SMA STP-TL-US 3401-3402, SMA SC-CP-XT 3403, SMA SC-CP-XT 3404, SMA SC-CP-XT 3406, SMA SI-US W853, SMA SI-US W863, SMA SI-US W873, SMA SI-US W883
Schneider Electric
Schneider Electric CL125 040
Solis
Solis 1P-4G-US OV-DC, Solis 3P-5G-US OV-DC01/02/03/04, Solis RHI-1P-HV OV-DC01/02/03/04, Solis S5-GC OV-DC, Solis S6-EH1P OV-DC01/02/03/04, Solis S6-EH2P OV-DC01, Solis S6-EH2P OV-DC02, Solis S6-EH3P30-60K OV-DC01, Solis S6-EH3P30-60K OV-DC02, Solis S6-EH3P75-150K OV-DC01, Solis S6-EH3P75-150K OV-DC02, Solis S6-GC OV-DC, Solis S6-GU OV-DC
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL PV1 (2) VoltOver, Yaskawa Solectria PVI-25TL-R PVVoltOver, Yaskawa Solectria PVI-TL PV1 (2) VoltOver, Yaskawa Solectria SGI-XTM DC Volt High

Same code in other families

Claims

defined_in

c1 drafted · lead CSI Installation Manual 50-66K T480GL01-UB LSW USA V1.1

reports

c2 drafted · lead DC overvoltage

detected_by

c3 drafted · lead DC voltage measurement

mitigated_by

c4 drafted · lead String configuration correction

Applies when measured string voltage is high due to too many modules.

review note: support check: partial - Passages say too many panels in string causes high DCV but do not explicitly state a string configuration correction action.

c6 drafted · lead Inverter replacement

Escalation when display reading suggests faulty measurement circuit.

affects

c5 drafted · lead PV array

applies_to

c7 drafted · lead CSI-50/60/66K-T480GL01-UB