Fault codes › Solis › Solis S6-EH3P(30-60)K-NV-YD-H-US

Solis S6-EH3P30-60K OV-DC02

Code
OV-DC02
Shown as
DC 2 input overvoltage
Page
93
ID
fc:solis-s6-eh3p-30-60k-us-ovdc02
IRI
https://solarlattice.org/kb/fc/solis-s6-eh3p-30-60k-us-ovdc02
Status
active
Also known as
OV-DC02, ovdc02, Solis OV-DC02, DC 2 input overvoltage
Category
Inverters
Class fault drafted · lead
Production not stated
Clears after a manual reset drafted · lead

Decoded

Reports DC overvoltage; look at PV array; confirm with DC voltage measurement; do: inverter restart.

What can be behind DC overvoltage

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E002, ABB / FIMER PVS-166-175-TL E057, ABB / FIMER PVS-60-TL CODE:06, ABB / FIMER PVS-60-TL E002, ABB / FIMER PVS-60-TL E057, ABB / FIMER TRIO-20.0-27.6-TL CODE:06, ABB / FIMER TRIO-20.0-27.6-TL E002, ABB / FIMER TRIO-20.0-27.6-TL E057, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:06, ABB / FIMER UNO-DM-3.3-5.0-PLUS E002, ABB / FIMER UNO-DM-3.3-5.0-PLUS E057, ABB / FIMER UNO-DM-6.0-PLUS CODE:06, ABB / FIMER UNO-DM-6.0-PLUS E002, ABB / FIMER UNO-DM-6.0-PLUS E057
CPS
CPS SCA25KTL-208 PV2VoltOver, CPS SCA25KTL-480 PVVoltOver, CPS SCA36KTL PV2VoltOver, CPS SCA50-100K-T Fault4040, CPS SCA50-100K-T Protect0370, CPS SCA50-100K-T Protect0420, CPS SCA50-100K-T Protect0440, CPS SCA50-100K-T Protect0800, CPS SCA50-100K-T Protect0830, CPS SCA50-100K-T Protect0860, CPS SCA50-60KTL PV2VoltOver, CPS SCH100-125KTL PVVoltOver, CPS SCH125KTL-AIO PVVoltOver, CPS SCH275KTL PVVoltOver, CPS SCH350KTL PVVoltOver
Canadian Solar
Canadian Solar 125K-T600GL02 OV-DC, Canadian Solar 125KTL-GS-E OV-DC, Canadian Solar 185-255K OV-DC01/02/03/04, Canadian Solar 23-28KTL-CT PVVoltOver, Canadian Solar 25-40K-T480GL01 OV-DC, Canadian Solar 25-40KTL-GS-FL OV-DC, Canadian Solar 50-66K-T480GL01 OV-DC, Canadian Solar 50-66KTL-GS-FL OV-DC, Canadian Solar 75-100K-T480GL02 OV-DC
Fronius
Fronius Galvo 309, Fronius Symo 309, Fronius Symo 313
Huawei
Huawei SUN2000-100KTL-USH0 2001, Huawei SUN2000-25-30KTL-US 103, Huawei SUN2000-45KTL-US-HV-D0 103
KACO new energy
KACO new energy blueplanet TL3 118, KACO new energy blueplanet TL3 119, KACO new energy blueplanet TL3 38, KACO new energy blueplanet TL3 60
SMA
SMA SB-US-40 3401-3407, SMA SB-US-41 3401, SMA SB-US-41 3402, SMA SB-US-41 3407, SMA SBSE-US-50 3401, SMA SBSE-US-50 3402, SMA SBSE-US-50 3407, SMA SBSE-US-50 3410, SMA SBSE-US-50 3411, SMA CORE1-US 3401, SMA CORE1-US 3402, SMA CORE1-US 3404, SMA CORE1-US 3407, SMA CORE1-US 3410, SMA CORE1-US 3411, SMA CORE1-US 3412, SMA STP-TL-US 3401-3402, SMA SC-CP-XT 3403, SMA SC-CP-XT 3404, SMA SC-CP-XT 3406, SMA SI-US W853, SMA SI-US W863, SMA SI-US W873, SMA SI-US W883
Schneider Electric
Schneider Electric CL125 040
Solis
Solis 1P-4G-US OV-DC, Solis 3P-5G-US OV-DC01/02/03/04, Solis RHI-1P-HV OV-DC01/02/03/04, Solis S5-GC OV-DC, Solis S6-EH1P OV-DC01/02/03/04, Solis S6-EH2P OV-DC01, Solis S6-EH2P OV-DC02, Solis S6-EH3P30-60K OV-DC01, Solis S6-EH3P75-150K OV-DC01, Solis S6-EH3P75-150K OV-DC02, Solis S6-GC OV-DC, Solis S6-GU OV-DC
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL PV1 (2) VoltOver, Yaskawa Solectria PVI-25TL-R PVVoltOver, Yaskawa Solectria PVI-TL PV1 (2) VoltOver, Yaskawa Solectria SGI-XTM DC Volt High

Same code in other families

Claims

defined_in

c1 drafted · lead Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1_0_20260908

c2 drafted · lead Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1.0_20251202

reports

c3 drafted · lead DC overvoltage

affects

c4 drafted · lead PV array

review note: support check: partial - The passages say to check PV voltage, which implies PV input, but the PV array is not named.

detected_by

c5 drafted · lead DC voltage measurement

review note: support check: partial - The passages say to check whether PV voltage is abnormal, but do not name DC voltage measurement.

mitigated_by

c6 drafted · lead Inverter restart

review note: support check: partial - Restart is suggested only to confirm whether the fault continues, not as a mitigation.

has_event_class

c7 drafted · lead Fault (device stops or needs intervention)

review note: support check: partial - Row describes an overvoltage fault with restart advice, but doesn't explicitly classify it as fault vs warning; fault is plausible…

has_recovery

c8 drafted · lead Manual reset (operator restarts or acknowledges)

Check PV voltage first, then restart; persistence after restart is checked.

applies_to

c9 drafted · lead Solis S6-EH3P(30-60)K-NV-YD-H-US

Data