Solis S6-EH3P(30-60)K-NV-YD-H-US
The Solis S6-EH3P(30-60)K-NV-YD-H-US is a family of three-phase hybrid inverters made by Solis for the US market. The family includes the 30K03 LV and NV models and the 40K04, 50K04 and 60K04 NV models, all with the (21A) suffix. The datasheet lists integrated AFCI for the 40K04 model, and the inverter reports an AFCI-Check message if its arc-fault self-test fails. The inverter talks to the battery over CAN. A CAN Fail alarm means that link is lost, so check the CAN cable and make sure the battery is powered on. A BatName-FAIL alarm means the battery model chosen under Battery Setting does not match the battery nameplate. The inverter raises DCInj-FAULT when the DC component of its output current is over the limit. Check the grid and the AC cabling, then restart. The 12Power-FAULT message means a 12V undervoltage failure; start by checking grounding and looking for current leaking to ground.
<!-- review notes
- sentence 1: support check: partial - Three-phase hybrid inverters by Solis are supported by the model names and title, but 'US market' is only implied by the -US suffix and 'three-phase' by EH3P naming, not stated.
- sentence 1: review: partial - The passages back a Solis hybrid inverter family with these models, but 'three-phase' and 'for the US market' are not stated and are only suggested by the model naming. -->
Claims
manufactured_by
instance_of
Described as a Solis hybrid inverter.
- Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1_0_20260908
fig=80h=8cd412c25b79 - Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1.0_20251202
fig=80h=8cd412c25b79
implements
c3 drafted · lead DC arc-fault protection
Datasheet lists integrated AFCI as Yes for the 40K04 model; an AFCI self-test failure message (AFCI-Check) is defined.
- Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1_0_20260908
tbl=31.r46h=b9cbf8ae2d2c - Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1.0_20251202
tbl=31.r46h=b9cbf8ae2d2c - Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1_0_20260908
tbl=29.r3h=9662b1a38062 - Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1.0_20251202
tbl=29.r3h=9662b1a38062
c5 drafted · lead DC injection limitation
DCInj-FAULT is raised when the DC component of output current exceeds the limit.
- Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1_0_20260908
tbl=28.r1h=343ddc0a98d9 - Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1.0_20251202
tbl=28.r1h=343ddc0a98d9
review note: support check: partial - DCInj-FAULT is raised when DC component exceeds limit, but passages don't explicitly state the inverter implements DC injection limitation (though implied); the core is present.
uses_protocol
CAN communication between inverter and battery; loss raises a CAN Fail alarm.
- Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1.0_20251202
sec=h352h=fa95d55eedef
Referenced by
- Solis S6-EH3P30-60K 12Power-FAULT
applies_toc9 - Solis S6-EH3P30-60K AFCI-Check
applies_toc10 - Solis S6-EH3P30-60K ARC-FAULT
applies_toc9 - Solis S6-EH3P30-60K BatName-FAIL
applies_toc5 - Solis S6-EH3P30-60K CAN Fail
applies_toc5 - Solis S6-EH3P30-60K DCInj-Fault
applies_toc10 - Solis S6-EH3P30-60K DC-INTF
applies_toc12 - Solis S6-EH3P30-60K DSP-B-Fault
applies_toc9 - Solis S6-EH3P30-60K Fan Alarm
applies_toc6 - Solis S6-EH3P30-60K G-F-GLU
applies_toc9 - Solis S6-EH3P30-60K G-PHASE
applies_toc9 - Solis S6-EH3P30-60K GRID-INTF
applies_toc9 - Solis S6-EH3P30-60K GRID-INTF02
applies_toc8 - Solis S6-EH3P30-60K GridToLoad
applies_toc5 - Solis S6-EH3P30-60K IGBT-OV-I
applies_toc11 - Solis S6-EH3P30-60K IGFOL-F
applies_toc8 - Solis S6-EH3P30-60K ILeak-Check
applies_toc11 - Solis S6-EH3P30-60K ILeak-PRO01
applies_toc7 - Solis S6-EH3P30-60K ILeak-PRO02
applies_toc7 - Solis S6-EH3P30-60K ILeak-PRO03
applies_toc7 - Solis S6-EH3P30-60K ILeak-PRO04
applies_toc7 - Solis S6-EH3P30-60K INI-FAULT
applies_toc9 - Solis S6-EH3P30-60K LmtByDRM
applies_toc5 - Solis S6-EH3P30-60K LmtByEPM
applies_toc8 - Solis S6-EH3P30-60K LmtByFreq
applies_toc6 - Solis S6-EH3P30-60K LmtByTemp
applies_toc6 - Solis S6-EH3P30-60K LmtByUnFr
applies_toc5 - Solis S6-EH3P30-60K LmtByVar
applies_toc5 - Solis S6-EH3P30-60K LmtByVg
applies_toc5 - Solis S6-EH3P30-60K NO-Battery
applies_toc6 - Solis S6-EH3P30-60K NO-GRID
applies_toc11 - Solis S6-EH3P30-60K OV-BUS
applies_toc9 - Solis S6-EH3P30-60K OV-BUS-H
applies_toc7 - Solis S6-EH3P30-60K OV-DC01
applies_toc7 - Solis S6-EH3P30-60K OV-DC02
applies_toc9 - Solis S6-EH3P30-60K OV-DCA-I
applies_toc11 - Solis S6-EH3P30-60K OV-DCB-I
applies_toc9 - Solis S6-EH3P30-60K Over-Load
applies_toc7 - Solis S6-EH3P30-60K OV-G-F01
applies_toc9 - Solis S6-EH3P30-60K OV-G-F02
applies_toc9 - Solis S6-EH3P30-60K OV-G-I
applies_toc10 - Solis S6-EH3P30-60K OV-G-V01
applies_toc8 - Solis S6-EH3P30-60K OV-G-V02
applies_toc9 - Solis S6-EH3P30-60K OV-G-V03
applies_toc7 - Solis S6-EH3P30-60K OV-G-V04
applies_toc9 - Solis S6-EH3P30-60K OV-G-V05
applies_toc9 - Solis S6-EH3P30-60K OV-ILLC
applies_toc6 - Solis S6-EH3P30-60K OV-TEM
applies_toc12 - Solis S6-EH3P30-60K OV-VBackup
applies_toc7 - Solis S6-EH3P30-60K OV-Vbatt
applies_toc5 - Solis S6-EH3P30-60K OV-Vbatt-H
applies_toc6 - Solis S6-EH3P30-60K PV ISO-PRO01
applies_toc10 - Solis S6-EH3P30-60K PV ISO-PRO02
applies_toc10 - Solis S6-EH3P30-60K RelayChk-Fail
applies_toc9 - Solis S6-EH3P30-60K StandbySynoch
applies_toc4 - Solis S6-EH3P30-60K Surge Alarm
applies_toc7 - Solis S6-EH3P30-60K UNB-BUS
applies_toc7 - Solis S6-EH3P30-60K UN-BUS01
applies_toc7 - Solis S6-EH3P30-60K UN-BUS02
applies_toc7 - Solis S6-EH3P30-60K UN-G-F01
applies_toc9 - Solis S6-EH3P30-60K UN-G-F02
applies_toc9 - Solis S6-EH3P30-60K UN-G-V01
applies_toc8 - Solis S6-EH3P30-60K UN-G-V02
applies_toc9 - Solis S6-EH3P30-60K UN-TEM
applies_toc9 - Solis S6-EH3P30-60K UN-Vbatt