Solar Lattice

Fault codes › Solis › Solis S6-EH3P(30-60)K-NV-YD-H-US

Solis S6-EH3P30-60K OV-VBackup

Code
OV-VBackup
Shown as
Inverting overvoltage
Page
92
ID
fc:solis-s6-eh3p-30-60k-us-ovvbackup
IRI
https://solarlattice.org/kb/fc/solis-s6-eh3p-30-60k-us-ovvbackup
Status
active
Also known as
OV-VBackup, ovvbackup, Solis OV-VBackup, Inverting overvoltage
Category
Inverters
Class not stated
Production not stated
Clears after a manual reset drafted · lead

Decoded

Reports backup output AC overvoltage; look at backup power outlet; do: wiring and terminal check.

What can be behind Backup output AC overvoltage

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

SMA
SMA SB-US-40 9202, SMA SB-US-41 9202, SMA SBSE-US-50 9202
Solis
Solis RHI-1P-HV OV-VBackup, Solis S6-EH1P OV-VBackup, Solis S6-EH2P OV-VBackup, Solis S6-EH3P75-150K OV-VBackup

Same code in other families

Claims

defined_in

c1 drafted · lead Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1_0_20260908

c2 drafted · lead Solis_Manual_S6-EH3P(30-60)K-NV-YD-H-US(21A)_V1.0_20251202

reports

c3 drafted · lead Backup output AC overvoltage

affects

c4 drafted · lead Backup power outlet

mitigated_by

c5 drafted · lead Wiring and terminal check

has_recovery

c6 drafted · lead Manual reset (operator restarts or acknowledges)

Restart first; factory repair if the fault persists

applies_to

c7 drafted · lead Solis S6-EH3P(30-60)K-NV-YD-H-US