Solar Lattice

Fault codes › KACO new energy › KACO blueplanet 87.0-165 TL3

KACO new energy blueplanet TL3 60

Code
60
Shown as
Excessive generator voltage / excessive battery voltage
Page
104
ID
fc:kaco-blueplanet-87-165-tl3-60
IRI
https://solarlattice.org/kb/fc/kaco-blueplanet-87-165-tl3-60
Status
active
Also known as
60, KACO new energy 60, Excessive generator voltage / excessive battery voltage
Category
Inverters
Class not stated
Production stops verified · fact
Clears by itself drafted · lead

Decoded

Reports DC overvoltage; look at PV array; confirm with DC voltage measurement; do: string configuration correction.

What can be behind DC overvoltage

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E002, ABB / FIMER PVS-166-175-TL E057, ABB / FIMER PVS-60-TL CODE:06, ABB / FIMER PVS-60-TL E002, ABB / FIMER PVS-60-TL E057, ABB / FIMER TRIO-20.0-27.6-TL CODE:06, ABB / FIMER TRIO-20.0-27.6-TL E002, ABB / FIMER TRIO-20.0-27.6-TL E057, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:06, ABB / FIMER UNO-DM-3.3-5.0-PLUS E002, ABB / FIMER UNO-DM-3.3-5.0-PLUS E057, ABB / FIMER UNO-DM-6.0-PLUS CODE:06, ABB / FIMER UNO-DM-6.0-PLUS E002, ABB / FIMER UNO-DM-6.0-PLUS E057
CPS
CPS SCA25KTL-208 PV2VoltOver, CPS SCA25KTL-480 PVVoltOver, CPS SCA36KTL PV2VoltOver, CPS SCA50-100K-T Fault4040, CPS SCA50-100K-T Protect0370, CPS SCA50-100K-T Protect0420, CPS SCA50-100K-T Protect0440, CPS SCA50-100K-T Protect0800, CPS SCA50-100K-T Protect0830, CPS SCA50-100K-T Protect0860, CPS SCA50-60KTL PV2VoltOver, CPS SCH100-125KTL PVVoltOver, CPS SCH125KTL-AIO PVVoltOver, CPS SCH275KTL PVVoltOver, CPS SCH350KTL PVVoltOver
Canadian Solar
Canadian Solar 125K-T600GL02 OV-DC, Canadian Solar 125KTL-GS-E OV-DC, Canadian Solar 185-255K OV-DC01/02/03/04, Canadian Solar 23-28KTL-CT PVVoltOver, Canadian Solar 25-40K-T480GL01 OV-DC, Canadian Solar 25-40KTL-GS-FL OV-DC, Canadian Solar 50-66K-T480GL01 OV-DC, Canadian Solar 50-66KTL-GS-FL OV-DC, Canadian Solar 75-100K-T480GL02 OV-DC
Fronius
Fronius Galvo 309, Fronius Symo 309, Fronius Symo 313
Huawei
Huawei SUN2000-100KTL-USH0 2001, Huawei SUN2000-25-30KTL-US 103, Huawei SUN2000-45KTL-US-HV-D0 103
KACO new energy
KACO new energy blueplanet TL3 118, KACO new energy blueplanet TL3 119, KACO new energy blueplanet TL3 38
SMA
SMA SB-US-40 3401-3407, SMA SB-US-41 3401, SMA SB-US-41 3402, SMA SB-US-41 3407, SMA SBSE-US-50 3401, SMA SBSE-US-50 3402, SMA SBSE-US-50 3407, SMA SBSE-US-50 3410, SMA SBSE-US-50 3411, SMA CORE1-US 3401, SMA CORE1-US 3402, SMA CORE1-US 3404, SMA CORE1-US 3407, SMA CORE1-US 3410, SMA CORE1-US 3411, SMA CORE1-US 3412, SMA STP-TL-US 3401-3402, SMA SC-CP-XT 3403, SMA SC-CP-XT 3404, SMA SC-CP-XT 3406, SMA SI-US W853, SMA SI-US W863, SMA SI-US W873, SMA SI-US W883
Schneider Electric
Schneider Electric CL125 040
Solis
Solis 1P-4G-US OV-DC, Solis 3P-5G-US OV-DC01/02/03/04, Solis RHI-1P-HV OV-DC01/02/03/04, Solis S5-GC OV-DC, Solis S6-EH1P OV-DC01/02/03/04, Solis S6-EH2P OV-DC01, Solis S6-EH2P OV-DC02, Solis S6-EH3P30-60K OV-DC01, Solis S6-EH3P30-60K OV-DC02, Solis S6-EH3P75-150K OV-DC01, Solis S6-EH3P75-150K OV-DC02, Solis S6-GC OV-DC, Solis S6-GU OV-DC
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL PV1 (2) VoltOver, Yaskawa Solectria PVI-25TL-R PVVoltOver, Yaskawa Solectria PVI-TL PV1 (2) VoltOver, Yaskawa Solectria SGI-XTM DC Volt High

Claims

defined_in

c1 drafted · lead KACO blueplanet 87.0-165 TL3 Operating Manual EN 2020-10 (Siemens-hosted copy)

reports

c2 drafted · lead DC overvoltage

has_production_effect

c3 verified · fact Trip (production stops)

Feed-in does not start while PV voltage is too high

verified by: review-workflowverified on: 2026-10-23

has_recovery

c4 drafted · lead Auto-reset (clears by itself)

Feed-in begins once PV voltage falls below the threshold

affects

c5 verified · fact PV array

verified by: review-workflowverified on: 2026-10-23

detected_by

c6 drafted · lead DC voltage measurement

mitigated_by

c7 drafted · lead String configuration correction

When strings were wired in series instead of parallel

applies_to

c8 drafted · lead KACO blueplanet 87.0-165 TL3