Product
KACO blueplanet 87.0-165 TL3
- ID
prod:kaco-blueplanet-87-165-tl3
- IRI
https://solarlattice.org/kb/prod/kaco-blueplanet-87-165-tl3
- Status
- active
- Also known as
- blueplanet 87.0 TL3, blueplanet 92.0 TL3, blueplanet 105 TL3, blueplanet 110 TL3, blueplanet 125 TL3, blueplanet 137 TL3, blueplanet 150 TL3, blueplanet 155 TL3, blueplanet 165 TL3, KACO blueplanet 125 TL3 US, KACO blueplanet 105TL3, KACO blueplanet 155TL3, KACO blueplanet 165TL3
- Category
- Inverters
- Make
- kaco
- Product level
- family
The KACO blueplanet 87.0-165 TL3 is a family of three-phase string inverters made by KACO, with models from 87.0 TL3 up to 165 TL3. Each model is sold in order variants with their own KACO article numbers, for example the 110 TL3 M1 WM OD IIK0 and IIKX. Each inverter has a single MPP tracker. Maximum efficiency is listed as 98.8 percent for the 105TL3 and 99.1 percent for the 125 TL3 US. For communication the inverters use TCP/IP, Modbus TCP and SunSpec. The DC input has overvoltage protection but no polarity safeguard and no string fuses, so check string polarity before you connect. Grid monitoring is set per country. The unit shows its status on LEDs and has an aluminium housing. Installation is meant to be done by an authorised electrician. If the grid fuse trips, the manual points to possible hardware damage and says to contact KACO Service.
<!-- review notes
- sentence 1: support check: partial - Models 87.0 to 165 TL3 and KACO name are listed, but 'three-phase string inverters' is not stated in the passage (TL3 only implied).
- sentence 5: support check: partial - Overvoltage protection yes, no polarity safeguard, no string fuse are stated; the advice to check polarity is not in the passages.
- sentence 7: support check: partial - Fault row supports the grid fuse/hardware damage/contact Service; the heading only shows the manual is for an authorised electrician, installation not explicitly stated.
- sentence 1: review: partial - The heading lists KACO models from 87.0 TL3 to 165 TL3, but does not say they are three-phase string inverters.
- sentence 7: review: partial - The fault row supports the grid fuse, possible hardware damage and contacting KACO Service, but the heading only labels the manual 'Authorised electrician' and never says installation must be done by one.
-->
Claims
manufactured_by
c1 drafted · lead
KACO new energy
review note: support check: partial - Passage shows KACO blueplanet models but doesn't state the manufacturer as 'KACO new energy' explicitly (only KACO brand name).; review: partial - The passage is a KACO manual naming KACO blueplanet models, which supports KACO as the maker, but the full company name 'KACO new energy' is never stated.
uses_protocol
c2 drafted · lead
Modbus TCP
c3 drafted · lead
SunSpec information models
Listed as 'Sunspec' alongside TCP/IP and Modbus TCP in the communication row of the data sheet.
implements
c4 drafted · lead
Maximum power point tracking
One MPP control per inverter for the listed models.
c6 drafted · lead
Surge protection
Data sheet lists DC overvoltage protection as 'Yes'.
review note: support check: partial - DC overvoltage protection 'Yes' is stated, but surge protection is not explicitly equated with it.
lacks
c5 drafted · lead
Reverse polarity protection
Data sheet lists polarity safeguard as 'no'; string fuses are also not included.
requires
c7 drafted · lead
Licensed electrician
Manual is addressed to an authorised electrician.
efficiency
c8 drafted · lead
nominal 98.8 PERCENT
Conditions: Maximum efficiency, KACO blueplanet 105TL3
review note: possible conflict with c9 (same source; check the conditions); possible conflict with c10 (same source; check the conditions); possible conflict with c11 (same source; check the conditions); possible conflict with c13 (same source; check the conditions)
c9 drafted · lead
nominal 99.1 PERCENT
Conditions: Maximum efficiency, KACO blueplanet 125 TL3 US
review note: possible conflict with c8 (same source; check the conditions); possible conflict with c10 (same source; check the conditions); possible conflict with c11 (same source; check the conditions); possible conflict with c12 (same source; check the conditions); possible conflict with c13 (same source; check the conditions)
c10 verified · fact
nominal 99.2 PERCENT
Conditions: Maximum efficiency, value printed across the 155TL3/165TL3 columns
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c8 (same source; check the conditions); possible conflict with c9 (same source; check the conditions); possible conflict with c11 (same source; check the conditions); possible conflict with c12 (same source; check the conditions); possible conflict with c13 (same source; check the conditions)
c11 drafted · lead
nominal 98.5 PERCENT
Conditions: European efficiency, KACO blueplanet 105TL3
review note: possible conflict with c8 (same source; check the conditions); possible conflict with c9 (same source; check the conditions); possible conflict with c10 (same source; check the conditions); possible conflict with c12 (same source; check the conditions); possible conflict with c13 (same source; check the conditions)
c12 drafted · lead
nominal 98.8 PERCENT
Conditions: European efficiency, KACO blueplanet 125 TL3 US
review note: possible conflict with c9 (same source; check the conditions); possible conflict with c10 (same source; check the conditions); possible conflict with c11 (same source; check the conditions); possible conflict with c13 (same source; check the conditions)
c13 drafted · lead
nominal 99 PERCENT
Conditions: European efficiency, value printed across the 155TL3/165TL3 columns
review note: possible conflict with c8 (same source; check the conditions); possible conflict with c9 (same source; check the conditions); possible conflict with c10 (same source; check the conditions); possible conflict with c11 (same source; check the conditions); possible conflict with c12 (same source; check the conditions)
Referenced by
Data