Fault codes › KACO new energy › KACO blueplanet 87.0-165 TL3
KACO new energy blueplanet TL3 160
- Code
160
- Shown as
- Error: Grid relay L1
- Page
- 108
- ID
fc:kaco-blueplanet-87-165-tl3-160
- IRI
https://solarlattice.org/kb/fc/kaco-blueplanet-87-165-tl3-160
- Status
- active
- Also known as
- 160, KACO new energy 160, Error: Grid relay L1
- Category
- Inverters
Class
fault drafted · lead
Production
not stated
Clears
not stated
Decoded
Reports self-test failure; may indicate relay failure; look at grid tie relay.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E019, ABB / FIMER PVS-166-175-TL E020, ABB / FIMER PVS-166-175-TL E021, ABB / FIMER PVS-166-175-TL E022, ABB / FIMER PVS-166-175-TL E053, ABB / FIMER PVS-166-175-TL E078, ABB / FIMER PVS-60-TL E103, ABB / FIMER PVS-60-TL E019, ABB / FIMER PVS-60-TL E020, ABB / FIMER PVS-60-TL E021, ABB / FIMER PVS-60-TL E022, ABB / FIMER PVS-60-TL E053, ABB / FIMER PVS-60-TL E078, ABB / FIMER TRIO-20.0-27.6-TL E019, ABB / FIMER TRIO-20.0-27.6-TL E020, ABB / FIMER TRIO-20.0-27.6-TL E021, ABB / FIMER TRIO-20.0-27.6-TL E022, ABB / FIMER UNO-DM-3.3-5.0-PLUS E019, ABB / FIMER UNO-DM-3.3-5.0-PLUS E020, ABB / FIMER UNO-DM-3.3-5.0-PLUS E021, ABB / FIMER UNO-DM-3.3-5.0-PLUS E022, ABB / FIMER UNO-DM-3.3-5.0-PLUS E053, ABB / FIMER UNO-DM-3.3-5.0-PLUS E078, ABB / FIMER UNO-DM-6.0-PLUS E019, ABB / FIMER UNO-DM-6.0-PLUS E020, ABB / FIMER UNO-DM-6.0-PLUS E021, ABB / FIMER UNO-DM-6.0-PLUS E022, ABB / FIMER UNO-DM-6.0-PLUS E053, ABB / FIMER UNO-DM-6.0-PLUS E078
- CPS
- CPS SCA25KTL-208 Fault0150, CPS SCA25KTL-208 Protect0230, CPS SCA25KTL-480 Fault0150, CPS SCA25KTL-480 Protect0230, CPS SCA36KTL Fault0150, CPS SCA36KTL Protect0230, CPS SCA50-100K-T PFault0140, CPS SCA50-100K-T Protect0230, CPS SCA50-100K-T Protect0390, CPS SCA50-60KTL Fault0150, CPS SCA50-60KTL Protect0230, CPS SCH100-125KTL Fault0150, CPS SCH100-125KTL Protect0230, CPS SCH125KTL-AIO Fault0150, CPS SCH125KTL-AIO Protect0230, CPS SCH200-250K-T Fault0390, CPS SCH200-250K-T Protect0230, CPS SCH200-250K-T Protect0390, CPS SCH275KTL Fault0150, CPS SCH275KTL Protect0230, CPS SCH350KTL Fault0150, CPS SCH350KTL Protect0230
- Canadian Solar
- Canadian Solar 185-255K RelayChk-FAIL
- Fronius
- Fronius Galvo 245, Fronius Symo 245
- Huawei
- Huawei SUN2000-100KTL-USH0 2021, Huawei SUN2000-25-30KTL-US 411, Huawei SUN2000-45KTL-US-HV-D0 411
- KACO new energy
- KACO new energy blueplanet TL3 161, KACO new energy blueplanet TL3 162, KACO new energy blueplanet TL3 164, KACO new energy blueplanet TL3 165, KACO new energy blueplanet TL3 166, KACO new energy blueplanet TL3 188, KACO new energy blueplanet TL3 59
- SMA
- SMA SBSE-US-50 9007, SMA PEAK3-US 9007, SMA CORE1-US 8208, SMA CORE1-US 8209, SMA CORE1-US 9007, SMA STP-TL-US 8204, SMA STP-X-US 9007, SMA SC-CP-XT 6447, SMA SC-CP-XT 6457, SMA SC-CP-XT 6471, SMA SC-CP-XT 6472
- Solis
- Solis 1P-4G-US AFCI Check FAULT, Solis RHI-1P-HV AFCI Check FAULT, Solis S6-EH1P AFCI Check FAULT, Solis S6-EH2P AFCI-Check, Solis S6-EH2P ILeak-Check, Solis S6-EH3P30-60K AFCI-Check, Solis S6-EH3P30-60K ILeak-Check, Solis S6-EH3P75-150K AFCI-Check, Solis S6-EH3P75-150K ILeak-Check, Solis S6-GC AFCI-Check, Solis S6-GC DSP-SelfCheck, Solis S6-GC ILeak-Check, Solis S6-GU AFCI-Check, Solis S6-GU DSP-SelfCheck, Solis S6-GU ILeak-Check
- Sungrow
- Sungrow SG-CX-US 105
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL Arc Board Error, Yaskawa Solectria PVI-25TL-R Fault0150, Yaskawa Solectria PVI-25TL-R Protect0230, Yaskawa Solectria PVI-TL Arc Board Error, Yaskawa Solectria XGI-1500-1MW CRIT-11, Yaskawa Solectria XGI-1500-1MW CRIT-12, Yaskawa Solectria XGI-1500 CRIT-11, Yaskawa Solectria XGI-1500 CRIT-12, Yaskawa Solectria XGI-1500-DCG CRIT-11, Yaskawa Solectria XGI-1500-DCG CRIT-12
Claims
defined_in
c1 drafted · lead
KACO blueplanet 87.0-165 TL3 Operating Manual EN 2020-10 (Siemens-hosted copy)
reports
c2 drafted · lead
Self-test failure
Self-test finds the grid-side relay stuck; switch-on is not checked.
indicates
c3 drafted · lead
Relay failure
affects
c4 drafted · lead
Grid tie relay
has_event_class
c5 drafted · lead
Fault (device stops or needs intervention)
The row reports a device error with a defective relay.