Solar Lattice

Fault codes › SMA › Sunny Tripower CORE1-US (STP 33/50/62-US-41)

SMA CORE1-US 8209

Code
8209
Page
54
ID
fc:sma-stp-core1-us-8209
IRI
https://solarlattice.org/kb/fc/sma-stp-core1-us-8209
Status
active
Also known as
8209, SMA 8209
Category
Inverters
Class not stated
Production not stated
Clears needs service drafted · lead

Decoded

Reports self-test failure; look at arc fault detection board; do: firmware update, contact manufacturer service.

What can be behind Self-test failure

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E019, ABB / FIMER PVS-166-175-TL E020, ABB / FIMER PVS-166-175-TL E021, ABB / FIMER PVS-166-175-TL E022, ABB / FIMER PVS-166-175-TL E053, ABB / FIMER PVS-166-175-TL E078, ABB / FIMER PVS-60-TL E103, ABB / FIMER PVS-60-TL E019, ABB / FIMER PVS-60-TL E020, ABB / FIMER PVS-60-TL E021, ABB / FIMER PVS-60-TL E022, ABB / FIMER PVS-60-TL E053, ABB / FIMER PVS-60-TL E078, ABB / FIMER TRIO-20.0-27.6-TL E019, ABB / FIMER TRIO-20.0-27.6-TL E020, ABB / FIMER TRIO-20.0-27.6-TL E021, ABB / FIMER TRIO-20.0-27.6-TL E022, ABB / FIMER UNO-DM-3.3-5.0-PLUS E019, ABB / FIMER UNO-DM-3.3-5.0-PLUS E020, ABB / FIMER UNO-DM-3.3-5.0-PLUS E021, ABB / FIMER UNO-DM-3.3-5.0-PLUS E022, ABB / FIMER UNO-DM-3.3-5.0-PLUS E053, ABB / FIMER UNO-DM-3.3-5.0-PLUS E078, ABB / FIMER UNO-DM-6.0-PLUS E019, ABB / FIMER UNO-DM-6.0-PLUS E020, ABB / FIMER UNO-DM-6.0-PLUS E021, ABB / FIMER UNO-DM-6.0-PLUS E022, ABB / FIMER UNO-DM-6.0-PLUS E053, ABB / FIMER UNO-DM-6.0-PLUS E078
CPS
CPS SCA25KTL-208 Fault0150, CPS SCA25KTL-208 Protect0230, CPS SCA25KTL-480 Fault0150, CPS SCA25KTL-480 Protect0230, CPS SCA36KTL Fault0150, CPS SCA36KTL Protect0230, CPS SCA50-100K-T PFault0140, CPS SCA50-100K-T Protect0230, CPS SCA50-100K-T Protect0390, CPS SCA50-60KTL Fault0150, CPS SCA50-60KTL Protect0230, CPS SCH100-125KTL Fault0150, CPS SCH100-125KTL Protect0230, CPS SCH125KTL-AIO Fault0150, CPS SCH125KTL-AIO Protect0230, CPS SCH200-250K-T Fault0390, CPS SCH200-250K-T Protect0230, CPS SCH200-250K-T Protect0390, CPS SCH275KTL Fault0150, CPS SCH275KTL Protect0230, CPS SCH350KTL Fault0150, CPS SCH350KTL Protect0230
Canadian Solar
Canadian Solar 185-255K RelayChk-FAIL
Fronius
Fronius Galvo 245, Fronius Symo 245
Huawei
Huawei SUN2000-100KTL-USH0 2021, Huawei SUN2000-25-30KTL-US 411, Huawei SUN2000-45KTL-US-HV-D0 411
KACO new energy
KACO new energy blueplanet TL3 160, KACO new energy blueplanet TL3 161, KACO new energy blueplanet TL3 162, KACO new energy blueplanet TL3 164, KACO new energy blueplanet TL3 165, KACO new energy blueplanet TL3 166, KACO new energy blueplanet TL3 188, KACO new energy blueplanet TL3 59
SMA
SMA SBSE-US-50 9007, SMA PEAK3-US 9007, SMA CORE1-US 8208, SMA CORE1-US 9007, SMA STP-TL-US 8204, SMA STP-X-US 9007, SMA SC-CP-XT 6447, SMA SC-CP-XT 6457, SMA SC-CP-XT 6471, SMA SC-CP-XT 6472
Solis
Solis 1P-4G-US AFCI Check FAULT, Solis RHI-1P-HV AFCI Check FAULT, Solis S6-EH1P AFCI Check FAULT, Solis S6-EH2P AFCI-Check, Solis S6-EH2P ILeak-Check, Solis S6-EH3P30-60K AFCI-Check, Solis S6-EH3P30-60K ILeak-Check, Solis S6-EH3P75-150K AFCI-Check, Solis S6-EH3P75-150K ILeak-Check, Solis S6-GC AFCI-Check, Solis S6-GC DSP-SelfCheck, Solis S6-GC ILeak-Check, Solis S6-GU AFCI-Check, Solis S6-GU DSP-SelfCheck, Solis S6-GU ILeak-Check
Sungrow
Sungrow SG-CX-US 105
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL Arc Board Error, Yaskawa Solectria PVI-25TL-R Fault0150, Yaskawa Solectria PVI-25TL-R Protect0230, Yaskawa Solectria PVI-TL Arc Board Error, Yaskawa Solectria XGI-1500-1MW CRIT-11, Yaskawa Solectria XGI-1500-1MW CRIT-12, Yaskawa Solectria XGI-1500 CRIT-11, Yaskawa Solectria XGI-1500 CRIT-12, Yaskawa Solectria XGI-1500-DCG CRIT-11, Yaskawa Solectria XGI-1500-DCG CRIT-12

Claims

defined_in

c1 drafted · lead STP33-62-US-41-BA-en-13

c2 drafted · lead STP33-62-US-41 ops manual

c3 drafted · lead STP33-62-US-41-BA-en-14

c4 drafted · lead Events 8209 and 8212 with STP-US-41

reports

c5 drafted · lead Self-test failure

Arc fault detection self-test error, interference level too low.

affects

c6 drafted · lead Arc fault detection board

mitigated_by

c7 drafted · lead Firmware update

Knowledge base: verify firmware is current before calling service.

c8 drafted · lead Contact manufacturer service

has_recovery

c9 drafted · lead Service required

Manual says service must determine cause; knowledge base suggests firmware update first.

applies_to

c10 drafted · lead Sunny Tripower CORE1-US

Data