Self-test failure
A self-test failure means a device's built-in check of its own critical subsystems found a condition outside tolerance. First, restart the inverter: turn both the AC and DC switches off, wait for the energy to discharge, then turn both back on. The manuals give 1 minute for Protect0230 and 5 minutes for Fault0150. If the fault does not clear after the restart, the CPS manuals say to replace the inverter. On SMA STP inverters, a failed self-test of the arc-fault circuit interrupter must be investigated by Service. An aborted grid self-test (Italy only) calls for checking the AC connection and running the self-test again.
<!-- review notes
- sentence 4: support check: partial - Arc-fault self-test error requiring Service and the Italy-only abort with AC connection check are supported; 'running the self-test again' comes only from an unattributed 'Restart the self-test' passage (u27) not tied to event 9007, and 'must' and 'STP' are not explicit. -->
Referenced by
- ABB / FIMER PVS-166-175-TL E019
reportsc3 - ABB / FIMER PVS-166-175-TL E020
reportsc3 - ABB / FIMER PVS-166-175-TL E021
reportsc3 - ABB / FIMER PVS-166-175-TL E022
reportsc3 - ABB / FIMER PVS-166-175-TL E053
reportsc3 - ABB / FIMER PVS-166-175-TL E078
reportsc3 - ABB / FIMER PVS-60-TL E103
reportsc4 - ABB / FIMER PVS-60-TL E019
reportsc3 - ABB / FIMER PVS-60-TL E020
reportsc3 - ABB / FIMER PVS-60-TL E021
reportsc3 - ABB / FIMER PVS-60-TL E022
reportsc3 - ABB / FIMER PVS-60-TL E053
reportsc3 - ABB / FIMER PVS-60-TL E078
reportsc3 - ABB / FIMER TRIO-20.0-27.6-TL E019
reportsc3 - ABB / FIMER TRIO-20.0-27.6-TL E020
reportsc3 - ABB / FIMER TRIO-20.0-27.6-TL E021
reportsc3 - ABB / FIMER TRIO-20.0-27.6-TL E022
reportsc3 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E019
reportsc4 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E020
reportsc4 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E021
reportsc4 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E022
reportsc4 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E053
reportsc4 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E078
reportsc4 - ABB / FIMER UNO-DM-6.0-PLUS E019
reportsc4 - ABB / FIMER UNO-DM-6.0-PLUS E020
reportsc4 - ABB / FIMER UNO-DM-6.0-PLUS E021
reportsc4 - ABB / FIMER UNO-DM-6.0-PLUS E022
reportsc4 - ABB / FIMER UNO-DM-6.0-PLUS E053
reportsc4 - ABB / FIMER UNO-DM-6.0-PLUS E078
reportsc4 - Canadian Solar 185-255K RelayChk-FAIL
reportsc2 - CPS SCA25KTL-208 Fault0150
reportsc3 - CPS SCA25KTL-208 Protect0230
reportsc3 - CPS SCA25KTL-480 Fault0150
reportsc3 - CPS SCA25KTL-480 Protect0230
reportsc3 - CPS SCA36KTL Fault0150
reportsc3 - CPS SCA36KTL Protect0230
reportsc3 - CPS SCA50-100K-T PFault0140
reportsc2 - CPS SCA50-100K-T Protect0230
reportsc3 - CPS SCA50-100K-T Protect0390
reportsc3 - CPS SCA50-60KTL Fault0150
reportsc3 - CPS SCA50-60KTL Protect0230
reportsc3 - CPS SCH100-125KTL Fault0150
reportsc3 - CPS SCH100-125KTL Protect0230
reportsc3 - CPS SCH125KTL-AIO Fault0150
reportsc3 - CPS SCH125KTL-AIO Protect0230
reportsc3 - CPS SCH200-250K-T Fault0390
reportsc3 - CPS SCH200-250K-T Protect0230
reportsc3 - CPS SCH200-250K-T Protect0390
reportsc3 - CPS SCH275KTL Fault0150
reportsc3 - CPS SCH275KTL Protect0230
reportsc3 - CPS SCH350KTL Fault0150
reportsc3 - CPS SCH350KTL Protect0230
reportsc3 - Fronius Galvo 245
reportsc2 - Fronius Symo 245
reportsc2 - Huawei SUN2000-100KTL-USH0 2021
reportsc3 - Huawei SUN2000-25-30KTL-US 411
reportsc3 - Huawei SUN2000-45KTL-US-HV-D0 411
reportsc3 - KACO new energy blueplanet TL3 160
reportsc2 - KACO new energy blueplanet TL3 161
reportsc2 - KACO new energy blueplanet TL3 162
reportsc2 - KACO new energy blueplanet TL3 164
reportsc2 - KACO new energy blueplanet TL3 165
reportsc2 - KACO new energy blueplanet TL3 166
reportsc2 - KACO new energy blueplanet TL3 188
reportsc2 - KACO new energy blueplanet TL3 59
reportsc2 - SMA SBSE-US-50 9007
reportsc2 - SMA PEAK3-US 9007
reportsc2 - SMA CORE1-US 8208
reportsc3 - SMA CORE1-US 8209
reportsc5 - SMA CORE1-US 9007
reportsc4 - SMA STP-TL-US 8204
reportsc2 - SMA STP-X-US 9007
reportsc2 - SMA SC-CP-XT 6447
reportsc2 - SMA SC-CP-XT 6457
reportsc2 - SMA SC-CP-XT 6471
reportsc2 - SMA SC-CP-XT 6472
reportsc2 - Solis 1P-4G-US AFCI Check FAULT
reportsc3 - Solis RHI-1P-HV AFCI Check FAULT
reportsc2 - Solis S6-EH1P AFCI Check FAULT
reportsc2 - Solis S6-EH2P AFCI-Check
reportsc2 - Solis S6-EH2P ILeak-Check
reportsc2 - Solis S6-EH3P30-60K AFCI-Check
reportsc3 - Solis S6-EH3P30-60K ILeak-Check
reportsc3 - Solis S6-EH3P75-150K AFCI-Check
reportsc2 - Solis S6-EH3P75-150K ILeak-Check
reportsc2 - Solis S6-GC AFCI-Check
reportsc2 - Solis S6-GC DSP-SelfCheck
reportsc2 - Solis S6-GC ILeak-Check
reportsc2 - Solis S6-GU AFCI-Check
reportsc2 - Solis S6-GU DSP-SelfCheck
reportsc2 - Solis S6-GU ILeak-Check
reportsc2 - Sungrow SG-CX-US 105
reportsc3 - Yaskawa Solectria PVI-14-20TL Arc Board Error
reportsc3 - Yaskawa Solectria PVI-25TL-R Fault0150
reportsc3 - Yaskawa Solectria PVI-25TL-R Protect0230
reportsc3 - Yaskawa Solectria PVI-TL Arc Board Error
reportsc3 - Yaskawa Solectria XGI-1500-1MW CRIT-11
reportsc3 - Yaskawa Solectria XGI-1500-1MW CRIT-12
reportsc3 - Yaskawa Solectria XGI-1500 CRIT-11
reportsc5 - Yaskawa Solectria XGI-1500 CRIT-12
reportsc5 - Yaskawa Solectria XGI-1500-DCG CRIT-11
reportsc3 - Yaskawa Solectria XGI-1500-DCG CRIT-12
reportsc3 - Arc detection board failure
presents_asc4