ABB / FIMER UNO-DM-3.3-5.0-PLUS E019

Code
E019
Shown as
Ileak sense.fail
Vendor severity
Error
Page
130
ID
fc:abb-uno-dm-3-3-5-0-plus-us-e19
IRI
https://solarlattice.org/kb/fc/abb-uno-dm-3-3-5-0-plus-us-e19
Status
active
Also known as
E019, e19, ABB / FIMER E019, Ileak sense.fail
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears after a manual reset drafted · lead

Decoded

Reports self-test failure; may indicate current sensor fault; look at current sensor; do: inverter restart, contact manufacturer service.

What can be behind Self-test failure

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E019, ABB / FIMER PVS-166-175-TL E020, ABB / FIMER PVS-166-175-TL E021, ABB / FIMER PVS-166-175-TL E022, ABB / FIMER PVS-166-175-TL E053, ABB / FIMER PVS-166-175-TL E078, ABB / FIMER PVS-60-TL E103, ABB / FIMER PVS-60-TL E019, ABB / FIMER PVS-60-TL E020, ABB / FIMER PVS-60-TL E021, ABB / FIMER PVS-60-TL E022, ABB / FIMER PVS-60-TL E053, ABB / FIMER PVS-60-TL E078, ABB / FIMER TRIO-20.0-27.6-TL E019, ABB / FIMER TRIO-20.0-27.6-TL E020, ABB / FIMER TRIO-20.0-27.6-TL E021, ABB / FIMER TRIO-20.0-27.6-TL E022, ABB / FIMER UNO-DM-3.3-5.0-PLUS E020, ABB / FIMER UNO-DM-3.3-5.0-PLUS E021, ABB / FIMER UNO-DM-3.3-5.0-PLUS E022, ABB / FIMER UNO-DM-3.3-5.0-PLUS E053, ABB / FIMER UNO-DM-3.3-5.0-PLUS E078, ABB / FIMER UNO-DM-6.0-PLUS E019, ABB / FIMER UNO-DM-6.0-PLUS E020, ABB / FIMER UNO-DM-6.0-PLUS E021, ABB / FIMER UNO-DM-6.0-PLUS E022, ABB / FIMER UNO-DM-6.0-PLUS E053, ABB / FIMER UNO-DM-6.0-PLUS E078
CPS
CPS SCA25KTL-208 Fault0150, CPS SCA25KTL-208 Protect0230, CPS SCA25KTL-480 Fault0150, CPS SCA25KTL-480 Protect0230, CPS SCA36KTL Fault0150, CPS SCA36KTL Protect0230, CPS SCA50-100K-T PFault0140, CPS SCA50-100K-T Protect0230, CPS SCA50-100K-T Protect0390, CPS SCA50-60KTL Fault0150, CPS SCA50-60KTL Protect0230, CPS SCH100-125KTL Fault0150, CPS SCH100-125KTL Protect0230, CPS SCH125KTL-AIO Fault0150, CPS SCH125KTL-AIO Protect0230, CPS SCH200-250K-T Fault0390, CPS SCH200-250K-T Protect0230, CPS SCH200-250K-T Protect0390, CPS SCH275KTL Fault0150, CPS SCH275KTL Protect0230, CPS SCH350KTL Fault0150, CPS SCH350KTL Protect0230
Canadian Solar
Canadian Solar 185-255K RelayChk-FAIL
Fronius
Fronius Galvo 245, Fronius Symo 245
Huawei
Huawei SUN2000-100KTL-USH0 2021, Huawei SUN2000-25-30KTL-US 411, Huawei SUN2000-45KTL-US-HV-D0 411
KACO new energy
KACO new energy blueplanet TL3 160, KACO new energy blueplanet TL3 161, KACO new energy blueplanet TL3 162, KACO new energy blueplanet TL3 164, KACO new energy blueplanet TL3 165, KACO new energy blueplanet TL3 166, KACO new energy blueplanet TL3 188, KACO new energy blueplanet TL3 59
SMA
SMA SBSE-US-50 9007, SMA PEAK3-US 9007, SMA CORE1-US 8208, SMA CORE1-US 8209, SMA CORE1-US 9007, SMA STP-TL-US 8204, SMA STP-X-US 9007, SMA SC-CP-XT 6447, SMA SC-CP-XT 6457, SMA SC-CP-XT 6471, SMA SC-CP-XT 6472
Solis
Solis 1P-4G-US AFCI Check FAULT, Solis RHI-1P-HV AFCI Check FAULT, Solis S6-EH1P AFCI Check FAULT, Solis S6-EH2P AFCI-Check, Solis S6-EH2P ILeak-Check, Solis S6-EH3P30-60K AFCI-Check, Solis S6-EH3P30-60K ILeak-Check, Solis S6-EH3P75-150K AFCI-Check, Solis S6-EH3P75-150K ILeak-Check, Solis S6-GC AFCI-Check, Solis S6-GC DSP-SelfCheck, Solis S6-GC ILeak-Check, Solis S6-GU AFCI-Check, Solis S6-GU DSP-SelfCheck, Solis S6-GU ILeak-Check
Sungrow
Sungrow SG-CX-US 105
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL Arc Board Error, Yaskawa Solectria PVI-25TL-R Fault0150, Yaskawa Solectria PVI-25TL-R Protect0230, Yaskawa Solectria PVI-TL Arc Board Error, Yaskawa Solectria XGI-1500-1MW CRIT-11, Yaskawa Solectria XGI-1500-1MW CRIT-12, Yaskawa Solectria XGI-1500 CRIT-11, Yaskawa Solectria XGI-1500 CRIT-12, Yaskawa Solectria XGI-1500-DCG CRIT-11, Yaskawa Solectria XGI-1500-DCG CRIT-12

Same code in other families

Claims

defined_in

c1 drafted · lead FIMER UNO-DM-3.3-5.0-TL-PLUS-US-Q Product Manual RevB

c2 drafted · lead UNO-DM-3.3-5.0-TL-PLUS-US Product Manual RevA

has_event_class

c3 drafted · lead Fault (device stops or needs intervention)

from the code prefix

reports

c4 drafted · lead Self-test failure

indicates

c5 drafted · lead Current sensor fault

Leakage current sensor reading outside tolerance during pre-connection self-test.

affects

c6 drafted · lead Current sensor

has_production_effect

c7 drafted · lead Trip (production stops)

Occurs only before grid connection, so the inverter does not connect.

review note: support check: partial - The passages say the alarm occurs only before grid connection. They do not state that the inverter trips or does…

mitigated_by

c8 drafted · lead Inverter restart

c9 drafted · lead Contact manufacturer service

has_recovery

c10 drafted · lead Manual reset (operator restarts or acknowledges)

Power cycle first; contact service if the fault persists afterwards.

review note: support check: partial - Power cycle then contact service is stated, but clearing by manual reset is not stated.

applies_to

c11 drafted · lead UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US string inverter

Data