Current sensor
A current sensor measures electrical current inside an inverter. Inverters include AC current sensors and current sensors that feed the arc detector. In module-level monitoring systems, a current sensor such as the ACS712 is fitted to each module together with a voltage sensor. The measured power is then compared with a predicted value to flag faults. When the arc detector current sensor is defective, Fronius inverters show status code 247 and disconnect from the grid. If the code keeps coming back, call a Fronius-trained service technician. Fronius Symo inverters report an AC current sensor fault as status code 315. If current sensor calibration times out (code 314), grid feed-in stops briefly and the inverter goes back to its startup phase. A faulty RCMU sensor (code 474) stops the inverter from feeding current into the grid. If the code keeps coming back, contact the system installer. The AC current sensor can be replaced in the field. Yaskawa instructions say it is held by two nuts and removed with a 7 mm socket. Solis lists the AC current sensor among the parts for which alternate materials were added to its certification report.
<!-- review notes
- sentence 1: support check: partial - Passages show AC current sensor and arc detector current sensor faults, but do not define a current sensor as measuring electrical current inside an inverter or state that inverters include them.
- sentence 4: support check: partial - Code 315 is AC current sensor fault, but the passage does not mention Symo models specifically.
- sentence 7: support check: partial - Evidence mentions two nuts and a 7mm socket for AC current sensor replacement, but doesn't name Yaskawa or explicitly state field replaceability.
- sentence 8: support check: partial - Report update adds alternate materials including AC current sensor, but the passage doesn't mention Solis by name.
- sentence 1: review: partial - The status codes confirm that inverters have AC and arc-detector current sensors, but the definition that a current sensor measures current inside an inverter is not stated. -->
Referenced by
- Current transformer operation
related_toc3 - ABB / FIMER PVS-166-175-TL E019
affectsc5 - ABB / FIMER PVS-60-TL E019
affectsc5 - ABB / FIMER TRIO-20.0-27.6-TL E019
affectsc5 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E019
affectsc6 - ABB / FIMER UNO-DM-6.0-PLUS E019
affectsc6 - Canadian Solar 185-255K IG-AD
affectsc3 - Fronius Galvo 247
affectsc4 - Fronius Primo 474
affectsc3 - Fronius Symo 247
affectsc4 - Fronius Symo 314
affectsc3 - Fronius Symo 315
affectsc3 - Fronius Symo 474
affectsc3 - Generac PWRcell Inverter 0x8061
affectsc4 - Generac PWRcell Inverter 0x8062
affectsc4 - Generac PWRcell Inverter 0x8063
affectsc4 - Generac PWRcell Inverter 0x8064
affectsc4 - Generac PWRcell Inverter 0x8065
affectsc4 - Generac PWRcell Inverter 0x8066
affectsc4 - Generac PWRcell Inverter 0x8067
affectsc4 - Generac PWRcell Inverter 0x8069
affectsc4 - Generac PWRcell Inverter 0x806A
affectsc4 - Generac PWRcell Inverter 0x806B
affectsc4 - Generac PWRcell Inverter 0x806C
affectsc4 - Generac PWRcell Inverter 0x806D
affectsc4 - Generac PWRcell Inverter 0x806E
affectsc4 - Generac PWRcell Inverter 0x806F
affectsc4 - SMA STP-X-US 8501
affectsc3 - Solis 3P-5G-US IG-AD
affectsc3 - Solis RHI-1P-HV IG-AD
affectsc3 - Solis S6-EH1P IG-AD
affectsc3 - Solis S6-EH2P ILeak-Check
affectsc4 - Solis S6-EH3P30-60K ILeak-Check
affectsc5 - Solis S6-EH3P75-150K ILeak-Check
affectsc4 - Solis S6-GC IG-AD
affectsc3 - Solis S6-GC ILeak-Check
affectsc4 - Solis S6-GU IG-AD
affectsc3 - Solis S6-GU ILeak-Check
affectsc4 - Yaskawa Solectria PVI-25TL-R Protect0180
affectsc4 - Yaskawa Solectria SGI-XTM CT Failure
affectsc3 - Current sensor fault
affectsc1 - Meter CT ratio misconfiguration
affectsc2 - Accuenergy AcuCT current transformers
instance_ofc2 - Accuenergy AcuRCT / AcuCT-Flex Rogowski coils
instance_ofc2