- UNO-DM-3.3-5.0-TL-PLUS-US Product Manual RevA
sec=h1h=5bda5a0c5340
UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US string inverter
At 240 Vac the 4.6 model is rated 4600 W and the 5.0 model 5000 W. The later manual lists maximum output of 3300 W for the 3.3 model and 4200 W for the 3.8 model. For communication it uses Modbus RTU with SunSpec and the Aurora Protocol. The -SB-RA model versions add a DC switch, a wiring box, arc fault detection and a supply output for rapid shutdown.
Claims
manufactured_by
uses_protocol
c2 drafted · lead Modbus RTU
- FIMER UNO-DM-3.3-5.0-TL-PLUS-US-Q Product Manual RevB
tbl=11.r3h=3e1610df8945
c3 drafted · lead SunSpec Modbus
Listed as ModBus RTU (SunSpec).
- FIMER UNO-DM-3.3-5.0-TL-PLUS-US-Q Product Manual RevB
tbl=11.r3h=3e1610df8945
c4 drafted · lead Aurora Protocol proposed
- FIMER UNO-DM-3.3-5.0-TL-PLUS-US-Q Product Manual RevB
tbl=11.r3h=3e1610df8945
implements
c5 drafted · lead DC arc-fault protection
AFD listed for the -SB-RA model versions, which also include a DC switch, wiring box and RSD supply output.
- FIMER UNO-DM-3.3-5.0-TL-PLUS-US-Q Product Manual RevB
tbl=11.r27h=65d2ab8ce41a - FIMER UNO-DM-3.3-5.0-TL-PLUS-US-Q Product Manual RevB
tbl=9.r27h=661f0b626423
c6 drafted · lead Constant power factor mode
Power factor above 0.995, adjustable to +/-0.8.
- FIMER UNO-DM-3.3-5.0-TL-PLUS-US-Q Product Manual RevB
tbl=8.r31h=4946bac7c607
review note: support check: partial - The passage only gives PF >0.995 adj. ±0.8 for the 3.3/3.8 models, not 4.6/5.0, and doesn't explicitly say constant PF mode.
rated_power
Conditions: UNO-DM-4.6-PLUS, at 240 Vac
- UNO-DM-3.3-5.0-TL-PLUS-US Product Manual RevA
tbl=17.r20h=5524bc870f66
review note: possible conflict with c8 (same source; check the conditions)conflicts with: UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US string inverter (c9)conflicts with: UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US string inverter (c10)
c8 verified · fact nominal 5000 W
Conditions: UNO-DM-5.0-PLUS, at 240 Vac
- UNO-DM-3.3-5.0-TL-PLUS-US Product Manual RevA
tbl=17.r20h=5524bc870f66
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c7 (same source; check the conditions); review: the compiler-flagged conflict (prod:abb-uno-dm-3-3-5-0-plus-us#c9, prod:abb-uno-dm-3-3-5-0-plus-us#c10) is a scenario difference, resolved at review
Conditions: UNO-DM-3.3-PLUS, maximum output power at cos phi = 1, 240 Vac (US-Q manual RevB)
- FIMER UNO-DM-3.3-5.0-TL-PLUS-US-Q Product Manual RevB
tbl=8.r22h=b7ee34723400
review note: possible conflict with c10 (same source; check the conditions)conflicts with: UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US string inverter (c7)conflicts with: UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US string inverter (c8)
Conditions: UNO-DM-3.8-PLUS, maximum output power at cos phi = 1, 240 Vac (US-Q manual RevB)
- FIMER UNO-DM-3.3-5.0-TL-PLUS-US-Q Product Manual RevB
tbl=8.r22h=b7ee34723400
review note: possible conflict with c9 (same source; check the conditions)conflicts with: UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US string inverter (c7)conflicts with: UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US string inverter (c8)
max_input_voltage
c11 drafted · lead nominal 600 V
Conditions: Absolute maximum DC input voltage (Vmax,abs), UNO-DM-4.6-PLUS and UNO-DM-5.0-PLUS
- UNO-DM-3.3-5.0-TL-PLUS-US Product Manual RevA
tbl=17.r36h=a539d4883a61
review note: support check: partial - The 600 V appears only as a column label next to the Vmax,abs row, without a clear value statement.
efficiency
c12 drafted · lead nominal 97 PERCENT
Conditions: Maximum efficiency, UNO-DM-4.6-PLUS
- UNO-DM-3.3-5.0-TL-PLUS-US Product Manual RevA
tbl=17.r36h=a539d4883a61
review note: possible conflict with c13 (same source; check the conditions); possible conflict with c14 (same source; check the conditions); possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions)
c13 drafted · lead nominal 97.4 PERCENT
Conditions: Maximum efficiency, UNO-DM-5.0-PLUS
- UNO-DM-3.3-5.0-TL-PLUS-US Product Manual RevA
tbl=17.r36h=a539d4883a61
review note: possible conflict with c12 (same source; check the conditions); possible conflict with c14 (same source; check the conditions); possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions); possible conflict with c17 (same source; check the conditions)
c14 drafted · lead nominal 96 PERCENT
Conditions: CEC efficiency, UNO-DM-4.6-PLUS at 208 Vac
- UNO-DM-3.3-5.0-TL-PLUS-US Product Manual RevA
tbl=17.r37h=d977f0ab02c0
review note: possible conflict with c12 (same source; check the conditions); possible conflict with c13 (same source; check the conditions); possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions); possible conflict with c17 (same source; check the conditions)
c15 drafted · lead nominal 96.5 PERCENT
Conditions: CEC efficiency, UNO-DM-4.6-PLUS at 240 Vac
- UNO-DM-3.3-5.0-TL-PLUS-US Product Manual RevA
tbl=17.r37h=d977f0ab02c0
review note: possible conflict with c12 (same source; check the conditions); possible conflict with c13 (same source; check the conditions); possible conflict with c14 (same source; check the conditions); possible conflict with c17 (same source; check the conditions)
c16 drafted · lead nominal 96.5 PERCENT
Conditions: CEC efficiency, UNO-DM-5.0-PLUS at 208 Vac
- UNO-DM-3.3-5.0-TL-PLUS-US Product Manual RevA
tbl=17.r37h=d977f0ab02c0
review note: possible conflict with c12 (same source; check the conditions); possible conflict with c13 (same source; check the conditions); possible conflict with c14 (same source; check the conditions); possible conflict with c17 (same source; check the conditions)
c17 drafted · lead nominal 97 PERCENT
Conditions: CEC efficiency, UNO-DM-5.0-PLUS at 240 Vac
- UNO-DM-3.3-5.0-TL-PLUS-US Product Manual RevA
tbl=17.r37h=d977f0ab02c0
review note: possible conflict with c13 (same source; check the conditions); possible conflict with c14 (same source; check the conditions); possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions)
Referenced by
- ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:00
applies_toc5 - ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:01
applies_toc5 - ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:02
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:03
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:04
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:05
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:06
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E001
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E010
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E011
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E012
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E013
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E014
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E015
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E016
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E017
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E018
applies_toc10 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E019
applies_toc11 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E002
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E020
applies_toc11 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E021
applies_toc11 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E022
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E023
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E024
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E025
applies_toc15 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E026
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E027
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E028
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E029
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E003
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E030
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E031
applies_toc10 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E032
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E033
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E034
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E035
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E036
applies_toc10 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E004
applies_toc10 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E046
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E049
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E005
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E050
applies_toc11 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E053
applies_toc10 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E054
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E055
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E056
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E057
applies_toc10 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E058
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E006
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E007
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E077
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E078
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E079
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E081
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E084
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E089
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E009
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W001
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W010
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W011
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W012
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W013
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W015
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W017
applies_toc10 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W018
applies_toc10 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W019
applies_toc10 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W002
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W022
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W023
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W024
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W026
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W027
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W003
applies_toc9 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W004
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W046
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W047
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W048
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W049
applies_toc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W005
applies_toc8 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W058
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W006
applies_toc7 - ABB / FIMER UNO-DM-3.3-5.0-PLUS W007
applies_toc7 - APsmart RSD rapid shutdown system
compatible_withc11