APsmart RSD rapid shutdown system

ID
prod:apsmart-rsd
IRI
https://solarlattice.org/kb/prod/apsmart-rsd
Status
active
Also known as
RSD-S-PLC, RSD-D, RSD-START-KIT, APsmart Transmitter, RSD-D(S)-PLC, APsmart Rapid Shutdown System, Transmitter-PLC, Transmitter-PLC-1P, Transmitter-PLC Outdoor Kit
Category
MLPE
Make
apsmart
Product level
family

The APsmart RSD system is a module-level rapid shutdown solution for North America, made up of RSD-S-PLC or dual-input RSD-D module units and a Transmitter-PLC. While the transmitter is powered it sends a heartbeat signal that keeps the modules connected; when the transmitter is switched off or its signal is lost, the module units go into rapid shutdown and restart once power comes back. You can trigger a manual shutdown with the transmitter breaker switch, or with an optional emergency stop button box on the outdoor kit that cuts the transmitter's AC supply. The system meets the SunSpec rapid shutdown signaling requirements and NEC 690.12 in the 2017, 2020 and 2023 editions. The module units do not shut down automatically when an arc is detected. They reduce the risk for firefighters but do not remove the risk of an arc fire. It is listed as compatible with FIMER UNO-DM-TL-PLUS-US-Q inverters and with Yaskawa Solectria PVI-25TL wire box models, where it is shown as PVRSS certified. If the inverter already has a SunSpec-certified rapid shutdown transmitter built in, leave out the external Transmitter-PLC.

Claims

manufactured_by

c1 drafted · lead APsmart proposed

instance_of

c2 drafted · lead Module-level rapid shutdown device

implements

c3 drafted · lead PV rapid shutdown

Module units shut down when the Transmitter-PLC heartbeat signal is absent; manual shutdown via the Transmitter breaker switch.

uses_protocol

c4 drafted · lead SunSpec rapid shutdown signal

Heartbeat signal sent by the Transmitter-PLC over the PV conductors.

review note: support check: partial - SunSpec rapid shutdown signal and heartbeat are stated, but sending over the PV conductors is not stated.

c5 drafted · lead Power line communication

PLC transmitter keeps module units connected while powered.

review note: support check: partial - The transmitter keeping modules connected is stated, but the passages don't state power line communication as the medium beyond the 'PLC' name.

certified_to

c6 drafted · lead SunSpec Rapid Shutdown specification proposed

Sources state it meets SunSpec requirements.

review note: support check: partial - Passages say it meets SunSpec requirements, but not that it is certified to the SunSpec specification.

c7 drafted · lead NEC 2017 690.12 Rapid shutdown of PV systems on buildings proposed

review note: support check: partial - Passages say it meets/complies with NEC 2017 690.12, but do not say it is certified.

c8 drafted · lead NEC 2020 690.12 Rapid shutdown of PV systems on buildings proposed

review note: support check: partial - Passages say it meets/complies with NEC 2020 690.12, but not that it is certified.

c9 drafted · lead NEC 2023 690.12 Rapid shutdown of PV systems on buildings proposed

review note: support check: partial - Passages say it meets/complies with NEC 2023 690.12, but not that it is certified.

lacks

c10 drafted · lead DC arc-fault protection

No automatic shutdown on arc detection; designed to reduce fire-fighting risk but does not address arc fire risk.

compatible_with

c11 drafted · lead UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US string inverter

Conditions: UNO-DM-TL-PLUS-US-Q models, all versions, with RSD-D(S)-PLC and Transmitter-PLC

c12 drafted · lead UNO-DM-6.0-TL-PLUS-US string inverter

Conditions: UNO-DM-6.0-TL-PLUS-US-Q, all versions, with RSD-D(S)-PLC and Transmitter-PLC

c13 drafted · lead Solectria PVI-25TL-480-APS20 proposed

Conditions: RSD-S-PLC and RSD-D with inverter plus integrated wire box; listed as PVRSS certified

c14 drafted · lead Solectria PVI-25TL-208WB-APS wire box proposed

Conditions: RSD-S-PLC and RSD-D with wire box; listed as PVRSS certified

Data