Product
APsmart RSD rapid shutdown system
- ID
prod:apsmart-rsd
- IRI
https://solarlattice.org/kb/prod/apsmart-rsd
- Status
- active
- Also known as
- RSD-S-PLC, RSD-D, RSD-START-KIT, APsmart Transmitter, RSD-D(S)-PLC, APsmart Rapid Shutdown System, Transmitter-PLC, Transmitter-PLC-1P, Transmitter-PLC Outdoor Kit
- Category
- MLPE
- Make
- apsmart
- Product level
- family
The APsmart RSD system is a module-level rapid shutdown solution for North America, made up of RSD-S-PLC or dual-input RSD-D module units and a Transmitter-PLC. While the transmitter is powered it sends a heartbeat signal that keeps the modules connected; when the transmitter is switched off or its signal is lost, the module units go into rapid shutdown and restart once power comes back. You can trigger a manual shutdown with the transmitter breaker switch, or with an optional emergency stop button box on the outdoor kit that cuts the transmitter's AC supply. The system meets the SunSpec rapid shutdown signaling requirements and NEC 690.12 in the 2017, 2020 and 2023 editions. The module units do not shut down automatically when an arc is detected. They reduce the risk for firefighters but do not remove the risk of an arc fire. It is listed as compatible with FIMER UNO-DM-TL-PLUS-US-Q inverters and with Yaskawa Solectria PVI-25TL wire box models, where it is shown as PVRSS certified. If the inverter already has a SunSpec-certified rapid shutdown transmitter built in, leave out the external Transmitter-PLC.
Claims
manufactured_by
c1 drafted · lead
APsmart proposed
instance_of
c2 drafted · lead
Module-level rapid shutdown device
implements
c3 drafted · lead
PV rapid shutdown
Module units shut down when the Transmitter-PLC heartbeat signal is absent; manual shutdown via the Transmitter breaker switch.
uses_protocol
c4 drafted · lead
SunSpec rapid shutdown signal
Heartbeat signal sent by the Transmitter-PLC over the PV conductors.
review note: support check: partial - SunSpec rapid shutdown signal and heartbeat are stated, but sending over the PV conductors is not stated.
c5 drafted · lead
Power line communication
PLC transmitter keeps module units connected while powered.
review note: support check: partial - The transmitter keeping modules connected is stated, but the passages don't state power line communication as the medium beyond the 'PLC' name.
certified_to
c6 drafted · lead
SunSpec Rapid Shutdown specification proposed
Sources state it meets SunSpec requirements.
review note: support check: partial - Passages say it meets SunSpec requirements, but not that it is certified to the SunSpec specification.
c7 drafted · lead
NEC 2017 690.12 Rapid shutdown of PV systems on buildings proposed
review note: support check: partial - Passages say it meets/complies with NEC 2017 690.12, but do not say it is certified.
c8 drafted · lead
NEC 2020 690.12 Rapid shutdown of PV systems on buildings proposed
review note: support check: partial - Passages say it meets/complies with NEC 2020 690.12, but not that it is certified.
c9 drafted · lead
NEC 2023 690.12 Rapid shutdown of PV systems on buildings proposed
review note: support check: partial - Passages say it meets/complies with NEC 2023 690.12, but not that it is certified.
lacks
c10 drafted · lead
DC arc-fault protection
No automatic shutdown on arc detection; designed to reduce fire-fighting risk but does not address arc fire risk.
compatible_with
c11 drafted · lead
UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US string inverter
Conditions: UNO-DM-TL-PLUS-US-Q models, all versions, with RSD-D(S)-PLC and Transmitter-PLC
c12 drafted · lead
UNO-DM-6.0-TL-PLUS-US string inverter
Conditions: UNO-DM-6.0-TL-PLUS-US-Q, all versions, with RSD-D(S)-PLC and Transmitter-PLC
c13 drafted · lead
Solectria PVI-25TL-480-APS20 proposed
Conditions: RSD-S-PLC and RSD-D with inverter plus integrated wire box; listed as PVRSS certified
c14 drafted · lead
Solectria PVI-25TL-208WB-APS wire box proposed
Conditions: RSD-S-PLC and RSD-D with wire box; listed as PVRSS certified
Data