Fault codes › KACO new energy › KACO blueplanet 87.0-165 TL3

KACO new energy blueplanet TL3 111

Code
111
Shown as
Grid failure undervoltage L1
Page
107
ID
fc:kaco-blueplanet-87-165-tl3-111
IRI
https://solarlattice.org/kb/fc/kaco-blueplanet-87-165-tl3-111
Status
active
Also known as
111, KACO new energy 111, Grid failure undervoltage L1
Category
Inverters
Class fault verified · fact
Production stops drafted · lead
Clears not stated

Decoded

Reports grid undervoltage; look at AC cable; confirm with grid voltage measurement; do: grid settings check, AC connection check.

What can be behind Grid undervoltage

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL W005, ABB / FIMER PVS-60-TL CODE:04, ABB / FIMER PVS-60-TL W005, ABB / FIMER TRIO-20.0-27.6-TL CODE:04, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:04, ABB / FIMER UNO-DM-3.3-5.0-PLUS W005, ABB / FIMER UNO-DM-6.0-PLUS CODE:04, ABB / FIMER UNO-DM-6.0-PLUS W005
Canadian Solar
Canadian Solar 125K-T600GL02 UN-G-V, Canadian Solar 125KTL-GS-E UN-G-V, Canadian Solar 25-40K-T480GL01 UN-G-V, Canadian Solar 25-40KTL-GS-FL UN-G-V, Canadian Solar 50-66K-T480GL01 UN-G-V, Canadian Solar 50-66KTL-GS-FL UN-G-V, Canadian Solar 75-100K-T480GL02 UN-G-V
Fronius
Fronius Galvo 103, Fronius Galvo 213, Fronius Galvo 223, Fronius Primo 103, Fronius Symo 103, Fronius Symo 213, Fronius Symo 223, Fronius Symo 233
Huawei
Huawei SUN2000-100KTL-USH0 2033, Huawei SUN2000-25-30KTL-US 301, Huawei SUN2000-45KTL-US-HV-D0 301
KACO new energy
KACO new energy blueplanet TL3 112, KACO new energy blueplanet TL3 113, KACO new energy blueplanet TL3 41, KACO new energy blueplanet TL3 43, KACO new energy blueplanet TL3 45
SMA
SMA SB-US-40 202-206, SMA SB-US-41 202, SMA SB-US-41 0203, SMA SB-US-41 206, SMA SBSE-US-50 202, SMA SBSE-US-50 0203, SMA SBSE-US-50 206, SMA STP-TL-US 202-203, SMA SC-CP-XT 0203, SMA SC-CP-XT 0204, SMA SI-US W315, SMA SI-US W316, SMA SI-US W317, SMA SI-US W318
Schneider Electric
Schneider Electric CL125 004, Schneider Electric CL125 005
Solis
Solis 1P-4G-US UN-G-V, Solis 3P-5G-US UN-G-V01/02, Solis RHI-1P-HV UN-G-V01/02, Solis S5-GC UN-G-V, Solis S6-EH1P UN-G-V01/02, Solis S6-EH2P UN-G-V01, Solis S6-EH2P UN-G-V02, Solis S6-EH3P30-60K UN-G-V01, Solis S6-EH3P30-60K UN-G-V02, Solis S6-EH3P75-150K UN-G-V01, Solis S6-EH3P75-150K UN-G-V02, Solis S6-GC UN-G-V, Solis S6-GU UN-G-V
Sungrow
Sungrow SG-CX-US 004, Sungrow SG-CX-US 005, Sungrow SG200HX 004, Sungrow SG200HX 005, Sungrow SG250HX 4, Sungrow SG250HX 5, Sungrow SG350HX 004, Sungrow SG350HX 005
Yaskawa Solectria
Yaskawa Solectria SGI-XTM Vac Low, Yaskawa Solectria SGI-XTM Vac Very Low, Yaskawa Solectria XGI-1500-1MW WARN-10, Yaskawa Solectria XGI-1500-1MW WARN-11, Yaskawa Solectria XGI-1500-1MW WARN-9, Yaskawa Solectria XGI-1500-DCG WARN-10, Yaskawa Solectria XGI-1500-DCG WARN-11, Yaskawa Solectria XGI-1500-DCG WARN-9, Yaskawa Solectria XGI-1500 WARN-10, Yaskawa Solectria XGI-1500 WARN-11, Yaskawa Solectria XGI-1500 WARN-9

Claims

defined_in

c1 drafted · lead KACO blueplanet 87.0-165 TL3 Operating Manual EN 2020-10 (Siemens-hosted copy)

reports

c2 drafted · lead Grid undervoltage

affects

c3 drafted · lead AC cable

review note: support check: partial - Via 108's 'Check connection/cabling' the AC cabling is implied, but the passages never say the fault affects an AC cable.

detected_by

c4 drafted · lead Grid voltage measurement

review note: support check: partial - The grid voltage on the phase is outside limits, implying voltage monitoring, but a grid voltage measurement method is not…

mitigated_by

c5 drafted · lead Grid settings check

c6 drafted · lead AC connection check

has_event_class

c7 verified · fact Fault (device stops or needs intervention)

verified by: review-workflowverified on: 2026-10-23review note: support check: partial - The row defers to 108, which describes a shutdown (a fault). Fault is implied, but 111's own Per s. is…

has_production_effect

c8 drafted · lead Trip (production stops)

Row defers to the referenced overvoltage entry, which describes a shutdown when phase voltage leaves set limits.

applies_to

c9 drafted · lead KACO blueplanet 87.0-165 TL3

Data