Fault codes › KACO new energy › KACO blueplanet 87.0-165 TL3
KACO new energy blueplanet TL3 112
- Code
112
- Shown as
- Grid failure undervoltage L2
- Page
- 107
- ID
fc:kaco-blueplanet-87-165-tl3-112
- IRI
https://solarlattice.org/kb/fc/kaco-blueplanet-87-165-tl3-112
- Status
- active
- Also known as
- 112, KACO new energy 112, Grid failure undervoltage L2
- Category
- Inverters
Class
fault drafted · lead
Production
stops drafted · lead
Clears
not stated
Decoded
Reports grid undervoltage; look at AC cable; confirm with grid voltage measurement; do: grid settings check, AC connection check.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL W005, ABB / FIMER PVS-60-TL CODE:04, ABB / FIMER PVS-60-TL W005, ABB / FIMER TRIO-20.0-27.6-TL CODE:04, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:04, ABB / FIMER UNO-DM-3.3-5.0-PLUS W005, ABB / FIMER UNO-DM-6.0-PLUS CODE:04, ABB / FIMER UNO-DM-6.0-PLUS W005
- Canadian Solar
- Canadian Solar 125K-T600GL02 UN-G-V, Canadian Solar 125KTL-GS-E UN-G-V, Canadian Solar 25-40K-T480GL01 UN-G-V, Canadian Solar 25-40KTL-GS-FL UN-G-V, Canadian Solar 50-66K-T480GL01 UN-G-V, Canadian Solar 50-66KTL-GS-FL UN-G-V, Canadian Solar 75-100K-T480GL02 UN-G-V
- Fronius
- Fronius Galvo 103, Fronius Galvo 213, Fronius Galvo 223, Fronius Primo 103, Fronius Symo 103, Fronius Symo 213, Fronius Symo 223, Fronius Symo 233
- Huawei
- Huawei SUN2000-100KTL-USH0 2033, Huawei SUN2000-25-30KTL-US 301, Huawei SUN2000-45KTL-US-HV-D0 301
- KACO new energy
- KACO new energy blueplanet TL3 111, KACO new energy blueplanet TL3 113, KACO new energy blueplanet TL3 41, KACO new energy blueplanet TL3 43, KACO new energy blueplanet TL3 45
- SMA
- SMA SB-US-40 202-206, SMA SB-US-41 202, SMA SB-US-41 0203, SMA SB-US-41 206, SMA SBSE-US-50 202, SMA SBSE-US-50 0203, SMA SBSE-US-50 206, SMA STP-TL-US 202-203, SMA SC-CP-XT 0203, SMA SC-CP-XT 0204, SMA SI-US W315, SMA SI-US W316, SMA SI-US W317, SMA SI-US W318
- Schneider Electric
- Schneider Electric CL125 004, Schneider Electric CL125 005
- Solis
- Solis 1P-4G-US UN-G-V, Solis 3P-5G-US UN-G-V01/02, Solis RHI-1P-HV UN-G-V01/02, Solis S5-GC UN-G-V, Solis S6-EH1P UN-G-V01/02, Solis S6-EH2P UN-G-V01, Solis S6-EH2P UN-G-V02, Solis S6-EH3P30-60K UN-G-V01, Solis S6-EH3P30-60K UN-G-V02, Solis S6-EH3P75-150K UN-G-V01, Solis S6-EH3P75-150K UN-G-V02, Solis S6-GC UN-G-V, Solis S6-GU UN-G-V
- Sungrow
- Sungrow SG-CX-US 004, Sungrow SG-CX-US 005, Sungrow SG200HX 004, Sungrow SG200HX 005, Sungrow SG250HX 4, Sungrow SG250HX 5, Sungrow SG350HX 004, Sungrow SG350HX 005
- Yaskawa Solectria
- Yaskawa Solectria SGI-XTM Vac Low, Yaskawa Solectria SGI-XTM Vac Very Low, Yaskawa Solectria XGI-1500-1MW WARN-10, Yaskawa Solectria XGI-1500-1MW WARN-11, Yaskawa Solectria XGI-1500-1MW WARN-9, Yaskawa Solectria XGI-1500-DCG WARN-10, Yaskawa Solectria XGI-1500-DCG WARN-11, Yaskawa Solectria XGI-1500-DCG WARN-9, Yaskawa Solectria XGI-1500 WARN-10, Yaskawa Solectria XGI-1500 WARN-11, Yaskawa Solectria XGI-1500 WARN-9
Claims
defined_in
c1 drafted · lead
KACO blueplanet 87.0-165 TL3 Operating Manual EN 2020-10 (Siemens-hosted copy)
reports
c2 drafted · lead
Grid undervoltage
affects
c3 drafted · lead
AC cable
review note: support check: partial - Via 108's 'Check connection/cabling' the AC cabling is implied, but the passages never say the fault affects an AC cable.
detected_by
c4 drafted · lead
Grid voltage measurement
review note: support check: partial - The grid voltage on the phase is outside limits, implying voltage monitoring, but a grid voltage measurement method is not…
mitigated_by
c5 drafted · lead
Grid settings check
c6 drafted · lead
AC connection check
has_event_class
c7 drafted · lead
Fault (device stops or needs intervention)
review note: support check: partial - The row defers to 108, which describes a shutdown (a fault). Fault is implied, but 112's own Per s. is…
has_production_effect
c8 drafted · lead
Trip (production stops)
Row defers to the referenced overvoltage entry, which describes a shutdown when phase voltage leaves set limits.
applies_to
c9 drafted · lead
KACO blueplanet 87.0-165 TL3
Data