Fault codes › Yaskawa Solectria › Yaskawa Solectria XGI 1500-1MW
Yaskawa Solectria XGI-1500-1MW WARN-10
- Code
WARN-10
- Shown as
- AC Very Low Voltage 2 Detected
- Vendor severity
- Warning
- Page
- 66
- ID
fc:yaskawa-solectria-xgi-1500-1mw-warn10
- IRI
https://solarlattice.org/kb/fc/yaskawa-solectria-xgi-1500-1mw-warn10
- Status
- active
- Also known as
- WARN-10, warn10, Yaskawa Solectria WARN-10, AC Very Low Voltage 2 Detected
- Category
- Inverters
Production
stops drafted · lead
Decoded
Reports grid undervoltage; confirm with grid voltage measurement.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL W005, ABB / FIMER PVS-60-TL CODE:04, ABB / FIMER PVS-60-TL W005, ABB / FIMER TRIO-20.0-27.6-TL CODE:04, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:04, ABB / FIMER UNO-DM-3.3-5.0-PLUS W005, ABB / FIMER UNO-DM-6.0-PLUS CODE:04, ABB / FIMER UNO-DM-6.0-PLUS W005
- Canadian Solar
- Canadian Solar 125K-T600GL02 UN-G-V, Canadian Solar 125KTL-GS-E UN-G-V, Canadian Solar 25-40K-T480GL01 UN-G-V, Canadian Solar 25-40KTL-GS-FL UN-G-V, Canadian Solar 50-66K-T480GL01 UN-G-V, Canadian Solar 50-66KTL-GS-FL UN-G-V, Canadian Solar 75-100K-T480GL02 UN-G-V
- Fronius
- Fronius Galvo 103, Fronius Galvo 213, Fronius Galvo 223, Fronius Primo 103, Fronius Symo 103, Fronius Symo 213, Fronius Symo 223, Fronius Symo 233
- Huawei
- Huawei SUN2000-100KTL-USH0 2033, Huawei SUN2000-25-30KTL-US 301, Huawei SUN2000-45KTL-US-HV-D0 301
- KACO new energy
- KACO new energy blueplanet TL3 111, KACO new energy blueplanet TL3 112, KACO new energy blueplanet TL3 113, KACO new energy blueplanet TL3 41, KACO new energy blueplanet TL3 43, KACO new energy blueplanet TL3 45
- SMA
- SMA SB-US-40 202-206, SMA SB-US-41 202, SMA SB-US-41 0203, SMA SB-US-41 206, SMA SBSE-US-50 202, SMA SBSE-US-50 0203, SMA SBSE-US-50 206, SMA STP-TL-US 202-203, SMA SC-CP-XT 0203, SMA SC-CP-XT 0204, SMA SI-US W315, SMA SI-US W316, SMA SI-US W317, SMA SI-US W318
- Schneider Electric
- Schneider Electric CL125 004, Schneider Electric CL125 005
- Solis
- Solis 1P-4G-US UN-G-V, Solis 3P-5G-US UN-G-V01/02, Solis RHI-1P-HV UN-G-V01/02, Solis S5-GC UN-G-V, Solis S6-EH1P UN-G-V01/02, Solis S6-EH2P UN-G-V01, Solis S6-EH2P UN-G-V02, Solis S6-EH3P30-60K UN-G-V01, Solis S6-EH3P30-60K UN-G-V02, Solis S6-EH3P75-150K UN-G-V01, Solis S6-EH3P75-150K UN-G-V02, Solis S6-GC UN-G-V, Solis S6-GU UN-G-V
- Sungrow
- Sungrow SG-CX-US 004, Sungrow SG-CX-US 005, Sungrow SG200HX 004, Sungrow SG200HX 005, Sungrow SG250HX 4, Sungrow SG250HX 5, Sungrow SG350HX 004, Sungrow SG350HX 005
- Yaskawa Solectria
- Yaskawa Solectria SGI-XTM Vac Low, Yaskawa Solectria SGI-XTM Vac Very Low, Yaskawa Solectria XGI-1500-1MW WARN-11, Yaskawa Solectria XGI-1500-1MW WARN-9, Yaskawa Solectria XGI-1500-DCG WARN-10, Yaskawa Solectria XGI-1500-DCG WARN-11, Yaskawa Solectria XGI-1500-DCG WARN-9, Yaskawa Solectria XGI-1500 WARN-10, Yaskawa Solectria XGI-1500 WARN-11, Yaskawa Solectria XGI-1500 WARN-9
Same code in other families
Claims
defined_in
c1 drafted · lead
XGI 1500 1MW IOM DOCR-071091-H
has_event_class
c2 drafted · lead
Warning (device continues, a condition is flagged)
from the table header
reports
c3 drafted · lead
Grid undervoltage
has_production_effect
c4 drafted · lead
Trip (production stops)
has_recovery
c5 drafted · lead
Auto-reset (clears by itself)
Wait for the grid to recover; service if measurement differs by more than 2 percent
detected_by
c6 drafted · lead
Grid voltage measurement
applies_to
c7 drafted · lead
Solectria XGI 1500-1MW
Data