Solar Lattice

Fault codes › SMA › Sunny Island 4548-US / 6048-US

SMA SI-US W853

Code
W853
Shown as
Overvoltage PV array Sunny Island Charger 1
Vendor severity
1
Page
217
ID
fc:sma-sunny-island-us-w853
IRI
https://solarlattice.org/kb/fc/sma-sunny-island-us-w853
Status
active
Also known as
W853, w853, SMA W853, Overvoltage PV array Sunny Island Charger 1
Category
Inverters
Class warning drafted · lead
Production not stated
Clears not stated

Decoded

Reports DC overvoltage; look at PV array.

What can be behind DC overvoltage

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E002, ABB / FIMER PVS-166-175-TL E057, ABB / FIMER PVS-60-TL CODE:06, ABB / FIMER PVS-60-TL E002, ABB / FIMER PVS-60-TL E057, ABB / FIMER TRIO-20.0-27.6-TL CODE:06, ABB / FIMER TRIO-20.0-27.6-TL E002, ABB / FIMER TRIO-20.0-27.6-TL E057, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:06, ABB / FIMER UNO-DM-3.3-5.0-PLUS E002, ABB / FIMER UNO-DM-3.3-5.0-PLUS E057, ABB / FIMER UNO-DM-6.0-PLUS CODE:06, ABB / FIMER UNO-DM-6.0-PLUS E002, ABB / FIMER UNO-DM-6.0-PLUS E057
CPS
CPS SCA25KTL-208 PV2VoltOver, CPS SCA25KTL-480 PVVoltOver, CPS SCA36KTL PV2VoltOver, CPS SCA50-100K-T Fault4040, CPS SCA50-100K-T Protect0370, CPS SCA50-100K-T Protect0420, CPS SCA50-100K-T Protect0440, CPS SCA50-100K-T Protect0800, CPS SCA50-100K-T Protect0830, CPS SCA50-100K-T Protect0860, CPS SCA50-60KTL PV2VoltOver, CPS SCH100-125KTL PVVoltOver, CPS SCH125KTL-AIO PVVoltOver, CPS SCH275KTL PVVoltOver, CPS SCH350KTL PVVoltOver
Canadian Solar
Canadian Solar 125K-T600GL02 OV-DC, Canadian Solar 125KTL-GS-E OV-DC, Canadian Solar 185-255K OV-DC01/02/03/04, Canadian Solar 23-28KTL-CT PVVoltOver, Canadian Solar 25-40K-T480GL01 OV-DC, Canadian Solar 25-40KTL-GS-FL OV-DC, Canadian Solar 50-66K-T480GL01 OV-DC, Canadian Solar 50-66KTL-GS-FL OV-DC, Canadian Solar 75-100K-T480GL02 OV-DC
Fronius
Fronius Galvo 309, Fronius Symo 309, Fronius Symo 313
Huawei
Huawei SUN2000-100KTL-USH0 2001, Huawei SUN2000-25-30KTL-US 103, Huawei SUN2000-45KTL-US-HV-D0 103
KACO new energy
KACO new energy blueplanet TL3 118, KACO new energy blueplanet TL3 119, KACO new energy blueplanet TL3 38, KACO new energy blueplanet TL3 60
SMA
SMA SB-US-40 3401-3407, SMA SB-US-41 3401, SMA SB-US-41 3402, SMA SB-US-41 3407, SMA SBSE-US-50 3401, SMA SBSE-US-50 3402, SMA SBSE-US-50 3407, SMA SBSE-US-50 3410, SMA SBSE-US-50 3411, SMA CORE1-US 3401, SMA CORE1-US 3402, SMA CORE1-US 3404, SMA CORE1-US 3407, SMA CORE1-US 3410, SMA CORE1-US 3411, SMA CORE1-US 3412, SMA STP-TL-US 3401-3402, SMA SC-CP-XT 3403, SMA SC-CP-XT 3404, SMA SC-CP-XT 3406, SMA SI-US W863, SMA SI-US W873, SMA SI-US W883
Schneider Electric
Schneider Electric CL125 040
Solis
Solis 1P-4G-US OV-DC, Solis 3P-5G-US OV-DC01/02/03/04, Solis RHI-1P-HV OV-DC01/02/03/04, Solis S5-GC OV-DC, Solis S6-EH1P OV-DC01/02/03/04, Solis S6-EH2P OV-DC01, Solis S6-EH2P OV-DC02, Solis S6-EH3P30-60K OV-DC01, Solis S6-EH3P30-60K OV-DC02, Solis S6-EH3P75-150K OV-DC01, Solis S6-EH3P75-150K OV-DC02, Solis S6-GC OV-DC, Solis S6-GU OV-DC
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL PV1 (2) VoltOver, Yaskawa Solectria PVI-25TL-R PVVoltOver, Yaskawa Solectria PVI-TL PV1 (2) VoltOver, Yaskawa Solectria SGI-XTM DC Volt High

Claims

defined_in

c1 drafted · lead SI4548-6048-US-BE-en-21W

has_event_class

c2 drafted · lead Warning (device continues, a condition is flagged)

from the Type column

reports

c3 verified · fact DC overvoltage

verified by: review-workflowverified on: 2026-10-23

affects

c4 drafted · lead PV array

applies_to

c5 drafted · lead Sunny Island 4548-US / 6048-US

Data