c1 drafted · lead Canadian Solar
Manual published by CSI Solar Co., Ltd.
- CSI Installation Manual 50-66K T480GL01-UB LSW USA V1.1
sec=1.1h=0c121e513fd9 - CSI Installation Manual 50-66K T480GL01-UB LSW USA V1.1
sec=h1h=4606d502bf47
The CSI-50/60/66K-T480GL01-UB is a family of Canadian Solar three-phase grid-tied string inverters that turn PV array DC power into AC for local loads and the grid. The family has three models, rated 50 kW, 60 kW and 66 kW, all on a 480 V grid. Every model takes up to 1000 V DC input and runs at a nominal 60 Hz, with an operating range of 59.5 to 60.5 Hz. Maximum output current is 60.2 A on the 50K model and 79.4 A on the 66K model. Peak efficiency is 98.8 percent and CEC weighted efficiency is 98.4 percent. The units have built-in DC arc-fault protection (AFCI) and are rated for ambient temperatures from -25 to 60 °C. They communicate over RS485, and WiFi is available as an option.
<!-- review notes
manufactured_byc1 drafted · lead Canadian Solar
Manual published by CSI Solar Co., Ltd.
sec=1.1 h=0c121e513fd9sec=h1 h=4606d502bf47instance_ofsec=1.1 h=0c121e513fd9compatible_withc3 drafted · lead Grid-tied PV without storage
Scope: applications on-grid
sec=1.1 h=0c121e513fd9sec=h1 h=4606d502bf47implementsc4 drafted · lead DC arc-fault protection
Integrated AFCI listed for all three models
tbl=19.r34 h=fed76822c9f2tbl=15.r34 h=748809acd862tbl=17.r34 h=65eea733c8d6uses_protocoltbl=20.r17 h=1d1150897002review note: support check: partial - Interface RS485 is stated only for the 66K model; other models not shown in the passage.
Wi-Fi is optional
tbl=20.r17 h=1d1150897002review note: support check: partial - Optional WiFi is stated only for the 66K model row.
rated_powerc7 drafted · lead nominal 50 KiloW
Conditions: CSI-50K-T480GL01-UB at 480 V
tbl=6 h=1cd4d61bc461review note: possible conflict with c8 (same source; check the conditions); possible conflict with c9 (same source; check the conditions)
c8 drafted · lead nominal 60 KiloW
Conditions: CSI-60K-T480GL01-UB at 480 V
tbl=6 h=1cd4d61bc461review note: possible conflict with c7 (same source; check the conditions); possible conflict with c9 (same source; check the conditions)
c9 drafted · lead nominal 66 KiloW
Conditions: CSI-66K-T480GL01-UB at 480 V
tbl=6 h=1cd4d61bc461review note: possible conflict with c7 (same source; check the conditions); possible conflict with c8 (same source; check the conditions)
rated_output_currentConditions: Maximum output current, CSI-50K-T480GL01-UB
tbl=15.r20 h=79723a524b0fConditions: Maximum output current, CSI-66K-T480GL01-UB
tbl=19.r20 h=034713615d7amax_input_voltageConditions: Maximum DC input voltage, all three models
tbl=17.r3 h=2b45f112b911tbl=15.r3 h=808a7b2e0998tbl=19.r3 h=6e2fc72d7eddnominal_voltagec13 drafted · lead nominal 480 V
Conditions: Nominal AC grid voltage
tbl=6 h=1cd4d61bc461tbl=19.r15 h=b75771d74997frequencyc14 drafted · lead nominal 60 HZ
Conditions: Nominal grid frequency, all three models
tbl=19.r17 h=9e44da0e167etbl=15.r17 h=3661d3f32777tbl=17.r17 h=fa6531d06449c15 drafted · lead 59.5–60.5 HZ
Conditions: Operating frequency range, all three models
tbl=19.r18 h=e977f1b4ec43tbl=15.r18 h=43bcae587028tbl=17.r18 h=829839be2babefficiencyc16 drafted · lead nominal 98.8 PERCENT
Conditions: Peak efficiency, all three models
tbl=19.r30 h=59e0eaa2df4etbl=15.r30 h=0a1f35a880a4tbl=17.r30 h=e58401546918review note: possible conflict with c17 (same source; check the conditions); possible conflict with c18 (same source; check the conditions)
c17 drafted · lead nominal 98.4 PERCENT
Conditions: CEC weighted efficiency, all three models
tbl=19.r31 h=89e8b1d74f71tbl=17.r31 h=041af831aa85tbl=15.r31 h=c5fdfe42e7adreview note: possible conflict with c16 (same source; check the conditions); possible conflict with c18 (same source; check the conditions)
c18 drafted · lead ≥ 99.9 PERCENT
Conditions: MPPT efficiency, CSI-66K-T480GL01-UB
tbl=19.r32 h=3c007cc76fdfreview note: possible conflict with c16 (same source; check the conditions); possible conflict with c17 (same source; check the conditions)
operating_temperaturec19 drafted · lead -25–60 DEG_C
Conditions: Ambient operating temperature range, all three models
tbl=20.r7 h=11d4e8802600tbl=18.r7 h=daef79e24450tbl=16.r7 h=74113c64845eapplies_to c11applies_to c7applies_to c8applies_to c7applies_to c8applies_to c7applies_to c6applies_to c6applies_to c9applies_to c9applies_to c6applies_to c7