Fault codes › Yaskawa Solectria › Solectria PVI 14/20TL
Yaskawa Solectria PVI-14-20TL GridV.OutLim
- Code
GridV.OutLim
- Shown as
- Grid voltage exceeds the specified range
- Vendor severity
- Protection
- Page
- 49
- ID
fc:yaskawa-solectria-pvi-14-20tl-gridvoutlim
- IRI
https://solarlattice.org/kb/fc/yaskawa-solectria-pvi-14-20tl-gridvoutlim
- Status
- active
- Also known as
- GridV.OutLim, gridvoutlim, Yaskawa Solectria GridV.OutLim, Grid voltage exceeds the specified range
- Category
- Inverters
Class
fault drafted · lead
Production
not stated
Decoded
Reports grid voltage out of range; look at AC cable; confirm with grid voltage measurement; do: AC connection check, contact manufacturer service.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
- PVI 14-20TL IOM DOCR-070351-G — Yaskawa Solectria Solar · page 49 drafted · lead
tbl=12.r7 h=5446ad2f8947
tbl=12.r8 h=ffc9550a6b8b
tbl=12.r9 h=1c59ae17c9bc
tbl=12.r10 h=27d31db0ef7c
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- CPS
- CPS SCA25KTL-208 GridV.OutLim, CPS SCA25KTL-480 GridV.OutLim, CPS SCA36KTL GridV.OutLim, CPS SCA50-100K-T Protect0080, CPS SCA50-60KTL GridV.OutLim, CPS SCH100-125KTL GridV.OutLim, CPS SCH125KTL-AIO GridV.OutLim, CPS SCH200-250K-T GridV.OutLim, CPS SCH275KTL GridV.OutLim, CPS SCH350KTL GridV.OutLim
- Canadian Solar
- Canadian Solar 23-28KTL-CT GridV.OutLim
- Fronius
- Fronius Galvo 453, Fronius Primo 453, Fronius Symo 453
- Huawei
- Huawei SUN2000-25-30KTL-US 301, Huawei SUN2000-45KTL-US-HV-D0 301
- KACO new energy
- KACO new energy blueplanet TL3 47
- SMA
- SMA SC-CP-XT 1500, SMA SI-US W335, SMA SI-US W336, SMA SI-US W337, SMA SI-US W338, SMA SI-US W807
- Schneider Electric
- Schneider Electric CL125 013, Schneider Electric CL125 003, Schneider Electric CL125 053
- Sungrow
- Sungrow SG-CX-US 013, Sungrow SG200HX 013, Sungrow SG250HX 13, Sungrow SG350HX 013
- Yaskawa Solectria
- Yaskawa Solectria PVI-25TL-R GridV.OutLim, Yaskawa Solectria PVI-TL GridV.OutLim
Same code in other families
Claims
defined_in
c1 drafted · lead
PVI 14-20TL IOM DOCR-070351-G
has_event_class
c2 drafted · lead
Fault (device stops or needs intervention)
from the Type column
reports
c3 drafted · lead
Grid voltage out of range
detected_by
c4 drafted · lead
Grid voltage measurement
review note: support check: partial - Passages say verify grid voltage within range but do not state the fault is detected by grid voltage measurement.
affects
c5 drafted · lead
AC cable
mitigated_by
c6 drafted · lead
AC connection check
c7 drafted · lead
Contact manufacturer service
Final escalation if the alarm persists.
has_recovery
c8 drafted · lead
Auto-reset (clears by itself)
Watch for automatic clearing first; then check grid and wiring, restart; then service.
applies_to
c9 drafted · lead
Solectria PVI 14-20TL