SMA SC-CP-XT 1500

Code
1500
Page
35
ID
fc:sma-sunny-central-cp-xt-1500
IRI
https://solarlattice.org/kb/fc/sma-sunny-central-cp-xt-1500
Status
active
Also known as
1500, SMA 1500
Category
Inverters
Class not stated
Production stops drafted · lead
Clears by itself drafted · lead

Decoded

Reports grid voltage out of range; confirm with grid frequency measurement, grid voltage measurement.

What can be behind Grid voltage out of range

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

CPS
CPS SCA25KTL-208 GridV.OutLim, CPS SCA25KTL-480 GridV.OutLim, CPS SCA36KTL GridV.OutLim, CPS SCA50-100K-T Protect0080, CPS SCA50-60KTL GridV.OutLim, CPS SCH100-125KTL GridV.OutLim, CPS SCH125KTL-AIO GridV.OutLim, CPS SCH200-250K-T GridV.OutLim, CPS SCH275KTL GridV.OutLim, CPS SCH350KTL GridV.OutLim
Canadian Solar
Canadian Solar 23-28KTL-CT GridV.OutLim
Fronius
Fronius Galvo 453, Fronius Primo 453, Fronius Symo 453
Huawei
Huawei SUN2000-25-30KTL-US 301, Huawei SUN2000-45KTL-US-HV-D0 301
KACO new energy
KACO new energy blueplanet TL3 47
SMA
SMA SI-US W335, SMA SI-US W336, SMA SI-US W337, SMA SI-US W338, SMA SI-US W807
Schneider Electric
Schneider Electric CL125 013, Schneider Electric CL125 003, Schneider Electric CL125 053
Sungrow
Sungrow SG-CX-US 013, Sungrow SG200HX 013, Sungrow SG250HX 13, Sungrow SG350HX 013
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL GridV.OutLim, Yaskawa Solectria PVI-25TL-R GridV.OutLim, Yaskawa Solectria PVI-TL GridV.OutLim

Claims

defined_in

c1 drafted · lead SCCPXT-E7-WA-en-37

reports

c2 drafted · lead Grid voltage out of range

Reconnection conditions not yet met after a grid error.

review note: support check: partial - Reconnection conditions not met after grid error is stated, but the row doesn't state grid voltage out of range specifically;…

detected_by

c3 drafted · lead Grid frequency measurement

review note: support check: partial - Corrective measure says check power frequency, but detection method is not explicitly stated.

c4 drafted · lead Grid voltage measurement

review note: support check: partial - Corrective measure says check grid voltage, but detection method is not explicitly stated.

has_production_effect

c5 drafted · lead Trip (production stops)

review note: support check: partial - Row only states reconnection conditions not yet met (W behavior); shutdown is implied by the general section for grid errors,…

has_recovery

c6 drafted · lead Auto-reset (clears by itself)

review note: support check: partial - Waiting for reconnection conditions implies auto resumption, but manual acknowledgment may be required depending on parameterization.

applies_to

c7 drafted · lead Sunny Central CP XT

Data