Solar Lattice

Fault codes › CPS › CPS SCA25KTL-DO-R/US-480

CPS SCA25KTL-480 GridV.OutLim

Code
GridV.OutLim
Page
107
ID
fc:chint-sca-25ktl-480-gridvoutlim
IRI
https://solarlattice.org/kb/fc/chint-sca-25ktl-480-gridvoutlim
Status
active
Also known as
GridV.OutLim, gridvoutlim, CPS GridV.OutLim
Category
Inverters
Class not stated
Production stops drafted · lead
Clears after a manual reset drafted · lead

Decoded

Reports grid voltage out of range; confirm with grid voltage measurement; do: AC connection check.

What can be behind Grid voltage out of range

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

CPS
CPS SCA25KTL-208 GridV.OutLim, CPS SCA36KTL GridV.OutLim, CPS SCA50-100K-T Protect0080, CPS SCA50-60KTL GridV.OutLim, CPS SCH100-125KTL GridV.OutLim, CPS SCH125KTL-AIO GridV.OutLim, CPS SCH200-250K-T GridV.OutLim, CPS SCH275KTL GridV.OutLim, CPS SCH350KTL GridV.OutLim
Canadian Solar
Canadian Solar 23-28KTL-CT GridV.OutLim
Fronius
Fronius Galvo 453, Fronius Primo 453, Fronius Symo 453
Huawei
Huawei SUN2000-25-30KTL-US 301, Huawei SUN2000-45KTL-US-HV-D0 301
KACO new energy
KACO new energy blueplanet TL3 47
SMA
SMA SC-CP-XT 1500, SMA SI-US W335, SMA SI-US W336, SMA SI-US W337, SMA SI-US W338, SMA SI-US W807
Schneider Electric
Schneider Electric CL125 013, Schneider Electric CL125 003, Schneider Electric CL125 053
Sungrow
Sungrow SG-CX-US 013, Sungrow SG200HX 013, Sungrow SG250HX 13, Sungrow SG350HX 013
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL GridV.OutLim, Yaskawa Solectria PVI-25TL-R GridV.OutLim, Yaskawa Solectria PVI-TL GridV.OutLim

Same code in other families

Claims

defined_in

c1 drafted · lead CPS 25kW User Manual Rev 2.1

reports

c2 drafted · lead Grid voltage out of range

detected_by

c3 drafted · lead Grid voltage measurement

review note: support check: partial - Passages imply AC voltage is checked against range but don't state a grid voltage measurement detection method.

mitigated_by

c4 drafted · lead AC connection check

has_production_effect

c5 drafted · lead Trip (production stops)

Restart needed implies inverter stopped

review note: support check: partial - Restart instruction implies stoppage but passages never state that feed-in stops or that it is a trip.

has_recovery

c6 drafted · lead Manual reset (operator restarts or acknowledges)

Restart after verifying grid connection; service if not cleared

applies_to

c7 drafted · lead CPS SCA25KTL-DO-R/US-480

Data