family

The Solectria PVI 14-20TL is a Yaskawa Solectria Solar family of transformerless three-phase string inverters made up of the PVI 14TL and PVI 20TL. The PVI 14TL delivers 14 kW continuous output at a nominal 208 VAC, and the PVI 20TL delivers 20 kW at a nominal 480 VAC. Both models accept an absolute maximum of 600 VDC. The MPPT range is 300 to 540 VDC on the 14TL and 300 to 550 VDC on the 20TL, with a per-zone input current limit of 25 A and 35 A respectively. Peak efficiency is 96.7 percent for the 14TL and 97.40 percent for the 20TL. CEC weighted efficiency is 96 and 97 percent. An internal arc board provides arc-fault shutdown (Arc Protect) and runs a self-check that raises Arc Board Error when it fails. Other alarms in the manual include GFCI.Err for high DC leakage current, GridV.OutLim for grid voltage out of range, EepromErr for memory faults and ExtFanErr for fan problems. The inverter has to be registered before its warranty becomes active.

<!-- review notes

Claims

manufactured_by

c1 drafted · lead Yaskawa Solectria Solar

instance_of

c2 drafted · lead Inverter

Datasheet describes the models as transformerless three-phase string inverters.

review note: support check: partial - Datasheet title references transformerless 3-ph string inverters, but the passage doesn't explicitly state it's an inverter in the evidence text beyond the URL.

implements

c3 drafted · lead DC arc-fault protection

An internal arc board shuts the inverter down on a possible arc fault (Arc Protect).

c4 drafted · lead Residual current monitoring

GFCI.Err is raised when DC leakage current exceeds the recommended value.

rated_power

c5 drafted · lead nominal 14 KiloW

Conditions: PVI 14TL continuous output power

review note: possible conflict with c6 (same source; check the conditions)

c6 drafted · lead nominal 20 KiloW

Conditions: PVI 20TL continuous output power

review note: possible conflict with c5 (same source; check the conditions)

nominal_voltage

c7 drafted · lead nominal 208 V

Conditions: PVI 14TL nominal AC output voltage

review note: possible conflict with c8 (same source; check the conditions)

c8 drafted · lead nominal 480 V

Conditions: PVI 20TL nominal AC output voltage

review note: possible conflict with c7 (same source; check the conditions)

max_input_voltage

c9 drafted · lead ≤ 600 V

Conditions: Absolute maximum DC input voltage, PVI 14TL and PVI 20TL

mppt_voltage_range

c10 drafted · lead 300–540 V

Conditions: PVI 14TL MPPT input voltage range

c11 drafted · lead 300–550 V

Conditions: PVI 20TL MPPT input voltage range

max_input_current

c12 drafted · lead ≤ 25 A

Conditions: PVI 14TL maximum operating input current per zone

c13 drafted · lead ≤ 35 A

Conditions: PVI 20TL maximum operating input current per zone

efficiency

c14 drafted · lead nominal 96.7 PERCENT

Conditions: PVI 14TL peak efficiency

review note: possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions); possible conflict with c17 (same source; check the conditions)

c15 drafted · lead nominal 97.4 PERCENT

Conditions: PVI 20TL peak efficiency

review note: possible conflict with c14 (same source; check the conditions); possible conflict with c16 (same source; check the conditions); possible conflict with c17 (same source; check the conditions)

c16 drafted · lead nominal 96 PERCENT

Conditions: PVI 14TL CEC weighted efficiency

review note: possible conflict with c14 (same source; check the conditions); possible conflict with c15 (same source; check the conditions); possible conflict with c17 (same source; check the conditions)

c17 drafted · lead nominal 97 PERCENT

Conditions: PVI 20TL CEC weighted efficiency

review note: possible conflict with c14 (same source; check the conditions); possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions)